骨水泥固定良好股骨柄周围假体周围髋部骨折固定中骨水泥层螺钉可能不影响股骨柄短期存活
本研究回顾性纳入28例Vancouver B1或C型假体周围股骨骨折患者,采用钢板结合至少1枚进入骨水泥层的螺钉固定,评估股骨柄存活情况。结果显示26例(92.9%)达到影像学愈合,2例(7.1%)骨不连均伴钢板失败并需翻修股骨假体,随访期间无股骨柄下沉、无骨水泥层骨折、无因股骨柄松动翻修。作者结论认为短期随访中骨水泥层螺钉未导致股骨柄松动。
要点
- 28例Vancouver B1或C型假体周围股骨骨折采用钢板联合骨水泥层螺钉固定,26例(92.9%)影像学愈合。
- 2例(7.1%)骨不连均与钢板失败相关,均需翻修股骨假体,翻修时假体未松动。
- 随访期间无股骨柄下沉、无骨水泥层骨折、无因股骨柄松动翻修。
核心结论
- 作者结论认为,在固定良好的股骨柄周围将螺钉固定进入骨水泥层,在短期随访中未导致股骨柄松动。
- 无因骨水泥层问题而单独行股骨假体翻修的病例。
研究设计与样本
- 回顾性综述,连续纳入2007年1月1日至2023年1月1日期间由3位外科医生手术治疗的假体周围股骨骨折患者。
- 共回顾112例于本机构治疗的Vancouver B1或C型假体周围股骨骨折连续患者,纳入采用钢板构造且至少1枚螺钉位于股骨柄周围骨水泥层内的患者。
- 最终28例患者符合纳入标准,其中女性19例,白人27例,西班牙裔或拉丁裔3例,平均年龄81.4±8.7岁。
- 随访至愈合、因钢板构造失败翻修或股骨柄翻修,平均随访时间33.3±24.0个月(范围6.1至86.2个月)。
主要发现
- 26例患者(92.9%)达到影像学愈合,平均愈合时间8.0±4.6个月(范围2.2至25.6周)。
- 研究包括8例(28.6%)全髋关节置换假体与全膝关节置换假体之间的假体间骨折。
- 发生2例骨不连(7.1%),均涉及钢板失败,两例患者均需翻修股骨假体,再次手术时假体未松动。
- 随访期间无股骨柄下沉或骨水泥层骨折发生,无因股骨柄松动而行翻修。
局限性
- 证据等级为治疗性IV级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Vancouver Type-B1 and C periprosthetic hip fractures have traditionally been treated using single- or double-plate fixation constructs. Concern exists regarding screws within the cement mantle due to the theoretical risk of cement fracture and eventual prosthetic loosening. The aim of this study was to assess femoral stem survivorship in patients with Vancouver Type-B1 or C fractures around a well-fixed cemented femoral component who were treated with a plate construct and screws into the cement mantle. The hypothesis was that screw fixation into the cement mantle would not compromise stem fixation. METHODS: A retrospective review was performed of patients who were consecutively, surgically treated for a periprosthetic fracture around a femoral stem by 3 surgeons, as identified through a search of records from January 1, 2007, to January 1, 2023. A total of 112 consecutive patients with Vancouver Type-B1 or C periprosthetic femoral fractures treated at our institutions were reviewed. Patients who underwent fixation using plate constructs with ≥1 screw within the cement mantle around the stem were included. Patients were followed until union, revision due to plate construct failure, or stem revision. Other complications, including alignment loss, cemented stem subsidence, radiographic stem loosening, and new cement-mantle fractures, were assessed. RESULTS: Twenty-eight patients (19 female; 27 White or Caucasian; 3 Hispanic or Latino; mean age, 81.4 ± 8.7 years) met the inclusion criteria. Radiographic union was achieved in 26 patients (92.9%). The study included 8 (28.6%) interprosthetic fractures between a total hip arthroplasty prosthesis and a total knee arthroplasty prosthesis. The mean union time was 8.0 ± 4.6 months (range, 2.2 to 25.6 weeks). The mean follow-up duration following the index procedure was 33.3 ± 24.0 months (range, 6.1 to 86.2 months). Two nonunions occurred (7.1%), both involving plate failure. Both patients required revision of the femoral prosthesis, which was not loose at the time of reoperation. No stem subsidence or cement mantle fractures occurred during follow-up, and no revisions were performed for stem loosening. CONCLUSIONS: Screw fixation into cement around a well-fixed stem did not contribute to stem loosening at short-term follow-up. There were no isolated femoral component revisions for cement mantle issues. LEVEL OF EVIDENCE: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
引用
- Shaw J, Patel RG, Sculco PK, et al. Cement Mantle Screws in Periprosthetic Hip Fracture Fixation Near Well-Fixed Femoral Stems May Not Impact Short-Term Femoral Stem Survivorship. J Bone Joint Surg Am. 2025. PMID: 40763211. doi:10.2106/JBJS.24.00920
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。