文献速递关节外科运动医学

髋关节微不稳中髂肌的磁共振成像特征:一项对比分析

Magnetic Resonance Imaging Characteristics of the Iliocapsularis in Hip Microinstability: A Comparative Analysis.
PubMed 文献 · Am J Sports Med · 2025-06-12

一项回顾性病例对照研究(证据等级4)纳入2014年1月至2022年12月因髋关节病变行关节镜手术的95例髋,按外侧中心边缘角分为临界发育性髋关节发育不良(BDDH,18°至<25°)、微不稳(MI,25°至39°)和混合型股骨髋臼撞击(mFAI,>39°)三组,比较髂肌(IC)尺寸与脂肪浸润。MI组IC深度、宽度、横截面积及IC+髂腰肌(IP)横截面积均显著更小(P<.05),但未观察到IC肥大;IC肌肉量对预测髋关节MI的预后价值有限。

要点

  • MI组IC深度、宽度、横截面积及IC+IP横截面积较BDDH和mFAI组显著更小(P<.05均)。
  • IC宽度(观察者间相关系数IRC=0.87)、IC横截面积(IRC=0.87)和IC+IP横截面积(IRC=0.96)观察者间一致性良好至优秀,IC深度一致性差(IRC=0.26)。
  • α角组间无显著差异(P=.093);MI组女性比例更高(P=.003)。

核心结论

  • 与BDDH和mFAI组相比,MI组未观察到可检测的IC肥大,MI患者IC宽度、深度和横截面积更小。
  • 该研究提供了一种观察者间一致性良好的可重复测量技术。
  • IC肌肉量对预测髋关节MI的预后价值有限。

研究设计与样本

  • 回顾性分析2014年1月至2022年12月因髋关节病变行关节镜手术的患者。
  • 病例对照研究,证据等级4。
  • 按外侧中心边缘角(LCEA)分为BDDH组(18°至<25°)、MI组(25°至39°)和mFAI组(>39°)。
  • 由3名独立观察者测量术前X线和MRI上的IC尺寸,包括宽度、深度、横截面积(CSA)、IC脂肪浸润及IC+IP横截面积。
  • 进行了先验效能分析;统计分析包括参数与非参数比较检验、观察者间相关系数和受试者工作特征分析。

主要发现

  • 共纳入95例髋。
  • MI组IC深度、宽度、横截面积及IC+IP横截面积均显著更小(P<.05均)。
  • IC宽度观察者间一致性良好至优秀(IRC=0.87),IC横截面积良好至优秀(IRC=0.87),IC+IP横截面积良好至优秀(IRC=0.96),IC深度差(IRC=0.26)。
  • α角组间无显著差异(P=.093)。
  • MI组女性患者比例更高(P=.003);放射学标志物包括坐骨棘征(P=.083)、交叉征(P=.130)和后壁征(P=.41)组间无显著差异。

关键数值与推荐

  • MI组IC深度、宽度、横截面积及IC+IP横截面积较BDDH和mFAI组显著更小(P<.05均)。
  • IC宽度观察者间相关系数IRC=0.87,IC横截面积IRC=0.87,IC+IP横截面积IRC=0.96,IC深度IRC=0.26。
  • α角组间比较P=.093;坐骨棘征P=.083;交叉征P=.130;后壁征P=.41。
  • MI组女性比例更高(P=.003)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Iliocapsularis (IC) muscle hypertrophy in borderline developmental dysplasia of the hip (BDDH) and developmental dysplasia of the hip (DDH) suggests a possible role as a dynamic hip stabilizer. However, its significance in hip microinstability (MI) without acetabular undercoverage remains unclear. PURPOSE: To compare IC muscle dimensions and fatty infiltration between patients with MI, BDDH, and mixed-type femoroacetabular impingement (mFAI), and assess the association between IC muscle morphology and hip pathology. STUDY DESIGN: Case-control study; Level of evidence, 4. METHODS: A retrospective analysis was conducted on patients undergoing arthroscopic surgery for hip pathology between January 2014 and December 2022. Patients were categorized based on lateral center-edge angle (LCEA) into BDDH (18° to <25°), MI (25° to 39°), and mFAI (>39°) groups. Preoperative radiographs and magnetic resonance imaging (MRI) scans were reviewed, and IC muscle dimensions, including width, depth, cross-sectional area (CSA), IC fatty infiltration, and combined IC and iliopsoas (IP) (IC+IP) CSA, were measured by 3 independent observers. A priori power analysis was performed. Statistical analyses included parametric and nonparametric comparative tests, interobserver correlation coefficients, and receiver operating characteristic analysis. RESULTS: A total of 95 hips were included in this study. IC depth, width, and CSA and IC+IP CSA were significantly smaller in the MI group (P < .05 for all). Interobserver agreement was good to excellent for IC width (IRC, 0.87), IC CSA (IRC, 0.87), and IC+IP CSA (IRC, 0.96), but poor for IC depth (IRC, 0.26). The alpha angle did not significantly differ among groups (P = .093). The MI group had a higher proportion of female patients (P = .003). No significant differences were noted in radiographic markers, including the ischial spine sign (P = .083), crossover sign (P = .130), and posterior wall sign (P = .41). CONCLUSION: No detectable IC hypertrophy was observed in the MI group compared with the BDDH and mFAI groups, with patients with MI showing smaller IC width, depth, and CSA. The study offers a reproducible measurement technique with good interobserver agreement. IC muscle mass has limited prognostic value in predicting hip MI.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Raji Y, Pierre KJ, Wagle S, et al. Magnetic Resonance Imaging Characteristics of the Iliocapsularis in Hip Microinstability: A Comparative Analysis. Am J Sports Med. 2025. PMID: 40503567. doi:10.1177/03635465251344600

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。