文献速递关节外科

年轻患者中高交联骨水泥聚乙烯髋臼杯的耐磨性更优:一项随机对照试验

Superior Wear Resistance of Highly Cross-Linked Cemented Polyethylene Cups in Young Patients: A Randomized Controlled Trial.
PubMed 文献 · J Arthroplasty · 2025-06-18

本研究为单盲随机对照试验,纳入50岁以下行初次全髋关节置换术的患者,比较骨水泥型高交联聚乙烯(HXLPE)杯与常规聚乙烯(CPE)杯的10年磨损。最终分析54例患者56髋(HXLPE组27髋,CPE组29髋),平均随访10.7年。HXLPE组线性磨损率和体积磨损率均显著低于CPE组,进展性骨溶解仅见于CPE组(4髋),无髋臼杯影像学松动或翻修。

要点

  • HXLPE组线性磨损率为0.037 mm/年,CPE组为0.109 mm/年。
  • HXLPE组体积磨损率为13.7 mm³/年,CPE组为26.6 mm³/年。
  • 进展性骨溶解仅见于CPE组(4髋),无影像学松动或翻修。

核心结论

  • 在50岁以下行全髋关节置换术的患者中,随访10年后,骨水泥型HXLPE髋臼杯的聚乙烯磨损率显著低于骨水泥型CPE杯。
  • 作者建议更长期随访以更全面了解年轻全髋关节置换术患者的假体寿命和固定情况。

研究设计与样本

  • 单盲随机对照试验,纳入50岁以下行初次全髋关节置换术的患者,排除因肿瘤疾病行全髋关节置换术者。
  • 最终分析纳入54例患者56髋(HXLPE组27髋,CPE组29髋),平均随访10.7年(范围9.0至12.3),手术时平均年龄36岁(范围17至49)。
  • 主要结局指标为线性磨损和体积磨损,次要结局指标为骨溶解、髋臼部件生存率和术后并发症;磨损结局通过比较基线和术后10年X线片评估。

主要发现

  • 线性磨损率HXLPE组为0.037 mm/年(范围0.02至0.07),CPE组为0.109 mm/年(范围0.04至0.25)。
  • 体积磨损率HXLPE组为13.7 mm³/年(范围2至43),CPE组为26.6 mm³/年(范围6至88)。
  • 进展性骨溶解仅见于CPE组(4髋)。
  • 无髋臼杯被判定为影像学松动,无髋臼杯行翻修。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者建议更长期随访以更全面了解年轻全髋关节置换术患者的假体寿命和固定情况。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Polyethylene wear of the acetabular component is related to periprosthetic osteolysis and subsequent aseptic loosening, requiring revision surgery. Highly cross-linked polyethylenes (HXLPEs) have been developed to mitigate wear. However, long-term randomized comparative studies focusing on acetabular component wear in young patients are scarce. Therefore, this study aimed to assess the 10-year polyethylene wear of cemented HXLPE compared to conventional polyethylene (CPE) cups in patients below 50 year old undergoing primary total hip arthroplasty (THA). METHODS: A single-blinded randomized controlled trial was developed. Inclusion criteria were primary THA below the age of 50 years. Exclusion criteria were THA due to an oncologic disease. Primary outcome measures were linear and volumetric wear. Secondary outcome measures were osteolysis, acetabular component survival, and postoperative complications. Wear outcomes were assessed by comparing baseline and 10-year postoperative radiographs. There were 54 patients who had 56 hips (27 HXLPE and 29 CPE) included in the final analysis. The mean follow-up was 10.7 years (range, 9.0 to 12.3). The mean age at surgery was 36 years (range, 17 to 49). RESULTS: Linear wear rate was 0.037 mm/year (range, 0.02 to 0.07) for the HXLPE group and 0.109 mm/year (range, 0.04 to 0.25) for the CPE group. Volumetric wear rate was 13.7 mm3/year (range, two to 43) for the HXLPE group and 26.6 mm3/year (range, six to 88) for the CPE group. Progressive osteolysis was found exclusively in the CPE group (four hips). None of the cups were considered radiologically loose, and none of the cups were revised. CONCLUSIONS: The HXLPE cemented acetabular cups demonstrate significantly reduced polyethylene wear rates compared to CPE cemented cups in young patients undergoing THA after 10 years of follow-up. However, longer follow-up is recommended to provide more comprehensive insights into implant longevity and fixation in these young THA patients. LEVEL OF EVIDENCE: Level I therapeutic study, randomized controlled trial.

来源:J Arthroplasty,查看原文。版权归原作者所有。