直接前入路全髋关节置换术股骨假体术后前倾角大于后入路
该回顾性数据库研究纳入807例(807髋)同时有术前和术后CT的全髋关节置换术,比较直接前入路(DAA,n=291)与后入路(PA,n=516)对股骨假体前倾角的影响。结果显示DAA组假体相对自体股骨颈轴的平均前倾角为6.0°(SD 9.8°),大于PA组的1.3°(SD 10.1°),差异有统计学意义(p<0.001)。作者结论为DAA置入的股骨假体平均前倾角大于PA,未来研究应探讨股骨假体前倾角对术后临床结局的影响。
要点
- DAA组股骨假体相对自体股骨颈轴平均前倾6.0°(SD 9.8°),PA组为1.3°(SD 10.1°),p<0.001。
- 在高自体前倾角亚组(≥25°)中,DAA平均前倾3.5°(SD 11.1°)vs PA的-5.8°(SD 10.5°),p<0.001。
- 在低自体前倾角亚组(≤5°)中,DAA平均前倾9.0°(SD 10.3°)vs PA的5.9°(SD 9.6°),p=0.109,未达统计学显著。
核心结论
- DAA置入的股骨假体平均前倾角大于PA置入者。
- 未来研究应探讨股骨假体前倾角对术后临床结局的影响。
研究设计与样本
- 回顾性数据库研究,纳入807例(807髋)同时有术前和术后CT的全髋关节置换术患者。
- 按手术入路分为DAA组(n=291)和PA组(n=516),使用四种股骨假体设计之一:四角锥形柄、股骨距引导短柄、平锥形柄或填充匹配型柄。
- 在第二次CT上测量股骨假体前倾角,与第一次CT测量的自体股骨颈轴比较,均以后侧股骨髁为参考。
- 亚组分析按低(≤5°)、中立(5°至25°)和高(≥25°)自体前倾角及不同假体类型进行。
主要发现
- 整体上,DAA组股骨假体相对自体股骨颈轴的平均前倾角为6.0°(SD 9.8°),PA组为1.3°(SD 10.1°),p<0.001。
- 多变量回归分析中,术后股骨假体前倾角增加的预测因素为入路(DAA)、术前自体前倾角减小、股骨矢状弓角减小和假体类型(四角锥形柄)。
- 高自体前倾角亚组(≥25°)中,DAA组平均前倾角为3.5°(SD 11.1°),PA组为-5.8°(SD 10.5°),p<0.001。
- 中立自体前倾角亚组(5°至25°)中,DAA组平均前倾角为5.2°(SD 9.3°),PA组为1.3°(SD 9.4°),p<0.001。
- 低自体前倾角亚组(≤5°)中,DAA组平均前倾角为9.0°(SD 10.3°),PA组为5.9°(SD 9.6°),p=0.109,未达统计学显著。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: There have been few studies that have investigated the effect of surgical approach on femoral component version in total hip arthroplasty (THA). The purpose of this study was to investigate the influence of the direct anterior approach (DAA) and the posterior approach (PA) on femoral component version in THA. METHODS: A retrospective database review of 807 THAs in 807 patients who had both preoperative and postoperative CT scans was performed. Femoral component version was measured in the second CT scan and compared to the native neck axis measured in the first CT scan, using the posterior femoral condyles as the reference for both. Operations were performed using either a DAA (n = 291) or a PA (n = 516), with one of four femoral component designs: quadrangular taper, calcar-guided short stem, flat taper, or fit-and-fill. Subgroup analyses investigated changes in version for low (≤ 5°), neutral (5° to 25°), and high (≥ 25°) native version subgroups and for the different femoral component types. RESULTS: Overall, DAA components had more mean anteversion relative to the native neck axis versus PA components (6.0° (SD 9.8°) vs 1.3° (SD 10.1°); p < 0.001). Predictors of increased femoral component anteversion postoperatively on multivariable regression analyses were approach (DAA), decreased native version preoperatively, decreased femoral sagittal bow angle, and component type (quadrangular taper). DAA components had greater mean anteversion relative to native than PA in hips with high native version (3.5° (SD 11.1°) vs -5.8° (SD 10.5°); p < 0.001) and neutral native version (5.2° (SD 9.3°) vs 1.3° (SD 9.4°); p < 0.001), but did not reach significance in the low native version subgroup (9.0° (SD 10.3°) vs 5.9° (SD 9.6°); p = 0.109). Quadrangular taper and calcar-guided short-component types had significantly more mean anteversion than native for DAA versus PA. CONCLUSION: Femoral components implanted with a DAA had more mean anteversion than those implanted with a PA. Future studies should aim to investigate the effect of femoral component version on postoperative clinical outcomes.
引用
- Sidhu VS, Plaskos C, Smith GH, et al. Femoral components implanted through a direct anterior approach have higher postoperative anteversion compared to those implanted through a posterior approach in total hip arthroplasty. Bone Joint J. 2025. PMID: 40306718. doi:10.1302/0301-620X.107B5.BJJ-2024-1101.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。