文献速递关节外科

叠置锥形套用于翻修全膝关节置换术治疗大量骨缺损:五年再手术率50%

Stacked Cones for the Treatment of Massive Bone Loss in Revision Total Knee Arthroplasty: 50% Reoperation Rate at Five Years.
PubMed 文献 · J Arthroplasty · 2025-05-06

本研究回顾了2011至2021年间单中心50例使用叠置锥形套的翻修全膝关节置换术,评估假体生存率、影像学结果与临床结局。平均随访5年,无因无菌性松动再翻修的5年生存率为93%,但无任何再手术的5年生存率仅50%。

要点

  • 叠置锥形套构建体无因无菌性松动再翻修的5年生存率为93%,无任何锥形套再翻修为75%。
  • 无任何再翻修和无任何再手术的5年生存率分别为58%和50%。
  • 17例再翻修中最常见原因为无菌性松动(8例)和假体周围感染(8例)。

核心结论

  • 叠置锥形套在平均5年随访中表现出中等水平的生存率,无菌性松动率低,但50%的病例需要再手术,凸显了该复杂队列及接受叠置锥形套患者的选择偏倚。

研究设计与样本

  • 单中心学术机构2011年至2021年间50例使用叠置锥形套的翻修全膝关节置换术的回顾性研究。
  • 叠置锥形套用于胫骨26例(52%)、股骨22例(44%)、两者均用2例(4%)。
  • 平均年龄69岁,平均体重指数33,74%为男性。
  • 平均随访5年(范围17天至10年)。

主要发现

  • 叠置锥形套构建体无因无菌性松动再翻修的5年生存率为93%,无任何叠置锥形套再翻修为75%。
  • 无任何再翻修和无任何再手术的5年生存率分别为58%和50%。
  • 共17例再翻修,无菌性松动(8例)和假体周围感染(8例)为最常见原因。
  • 9例叠置锥形套构建体被再翻修(股骨6例、胫骨3例),指征为假体周围感染(7例,其中3例有既往假体周围感染)和无菌性松动(2例)。
  • 2例未再翻修的叠置锥形套构建体有影像学松动迹象,平均膝关节协会评分为54分。

局限性

  • 原文指出50%的病例需要再手术,凸显了该复杂队列及接受叠置锥形套患者的选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Metaphyseal cones can be used to address bone loss and/or obtain reliable biologic fixation in revision total knee arthroplasties (TKAs). Sometimes, larger bone defects mandate using more than one cone on either the femoral or tibial side. This study aimed to evaluate implant survivorship, radiographic results, and clinical outcomes of revision TKAs with multiple stacked cones. METHODS: We identified 50 revision TKAs using stacked cones performed at a single academic institution from 2011 to 2021. Stacked cones were used in the tibia in 26 patients (52%), femur in 22 patients (44%), and both in two patients (4%). The mean age was 69 years, the mean body mass index was 33, and 74% were men. Kaplan-Meier survivorship curves were calculated, radiographs were reviewed, and clinical outcomes were evaluated with Knee Society Function Score. The mean follow-up was 5 years (range, 17 days to 10 years). RESULTS: The 5-year survivorship free of rerevision for aseptic loosening of the stacked cone constructs was 93%, and free of any stacked cone rerevision was 75%. There were nine stacked cone constructs (six femoral and three tibial) rerevised, with periprosthetic joint infection (PJI; n = 7; 3 with prior PJI) and aseptic loosening (n = 2) being the indications for rerevision. The 5-year survivorship free of any rerevision and any reoperation was 58 and 50%, respectively. There were 17 rerevisions, with aseptic loosening (n = 8) and PJI (n = 8) being the most common reasons. There were two nonrerevised stacked cone constructs that had signs of radiographic loosening. The mean Knee Society Score was 54. CONCLUSIONS: Stacked cones demonstrated modest survivorship at a mean 5-year follow-up with a low rate of aseptic loosening. However, 50% of these cases required a reoperation, highlighting this complex cohort and selection bias to those receiving stacked cones.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Pumford AD, Wright BH, Bedard NA, et al. Stacked Cones for the Treatment of Massive Bone Loss in Revision Total Knee Arthroplasty: 50% Reoperation Rate at Five Years. J Arthroplasty. 2025. PMID: 40339940. doi:10.1016/j.arth.2025.04.059

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。