既往金属对金属髋关节手术后翻修髋关节置换的10年临床回顾:术前磁共振成像与金属离子分析中外展肌腱撕脱预测脱位
本研究回顾性分析了56例因金属对金属(MoM)髋关节手术失败而接受翻修术且随访超过10年的患者。翻修术后平均牛津髋关节评分为37.4,再翻修率为16%,脱位率为11%,感染率为5%。术前磁共振成像显示的外展肌腱撕脱与术后脱位正相关(P=0.043),术前钴离子水平高于均值366.1 nmol/L与外展肌功能不全Goutallier分级3/4级相关(P=0.033)。
要点
- MoM髋翻修术后10年以上患者报告功能结局满意,平均牛津髋关节评分37.4。
- 再翻修率为16%,与两组假体组件均更换相关(P=0.029);脱位率为11%,感染率为5%。
- 术前MRI显示外展肌腱撕脱者占30%,与术后脱位正相关(P=0.043)。
核心结论
- 因MoM髋关节手术失败而接受翻修术后超过10年,可获得满意的患者报告功能结局。
- 但再翻修和脱位风险显著,可能通过MRI显示的外展肌功能不全和金属碎屑不良反应来预测。
研究设计与样本
- 回顾性队列研究,纳入本机构连续86例因无菌性MoM髋手术失败行翻修术的患者,其中56例完成至少10年随访。
- 翻修时平均年龄60岁(范围31至75岁),平均随访138个月(范围120至161个月)。
主要发现
- 平均牛津髋关节评分为37.4,MoM表面置换组平均36.1低于MoM全髋关节置换组平均38.0,P=0.46。
- 平均EuroQol-5-Dimension评分为8.9。
- 再翻修率为16%,与两组假体组件均更换相关,P=0.029。
- 总体脱位率为11%,5%发生感染。
- 术前MRI可用于46髋:外展肌腱撕脱占30%,与术后脱位正相关,P=0.043;假瘤形成占20%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is a paucity of long-term data following the revision of previous metal-on-metal (MoM) hip procedures. We hypothesized that functional and clinical results would be poor and that prerevision serum ion levels and magnetic resonance imaging (MRI) findings could predict the outcome. METHODS: All patients who had completed a minimum of 10 years following the revision of an MoM hip procedure at our institution were contacted. Data recorded were postrevision complication, rerevision, Oxford Hip Score, and EuroQol-5-Dimension Score, along with prerevision serum ion levels and MRI findings. There were 56 aseptic MoM revisions from a consecutive series of 86 that reached > 10 years of follow up. The mean age at revision surgery was 60 years (range, 31 to 75), and the mean follow up was 138 months (range, 120 to 161). RESULTS: The mean Oxford Hip Score was 37.4 and was lower in the MoM resurfacing group (mean 36.1) versus the MoM total hip arthroplasty group (mean 38.0), P = 0.46. The mean EuroQol-5-Dimension was 8.9. Rerevision rate was 16%, which was associated with the exchange of both components, P = 0.029. The overall dislocation rate was 11, and 5% developed infection. Preoperative MRI was available for 46 hips: abductor tendon avulsion was present in 30% and was positively associated with postoperative dislocation, P = 0.043. Pseudotumor formation was present in 20%. The mean metal ion levels preoperatively were cobalt, 366.1 nmol/L, and chromium, 211.6 nmol/L, with cobalt levels above our mean value of 366.1 nmol/L, associated with Goutallier grades 3/4 abductor insufficiency, P = 0.033 and trending toward association with pseudotumor formation, P = 0.087. CONCLUSIONS: Satisfactory patient-reported functional outcomes are attainable at over 10 years following revision surgery for failed MoM hip surgery. However, there is a significant risk of rerevision and dislocation, which may be predicted with MRI evidence of abductor insufficiency and adverse reaction to metal debris.
引用
- O'Driscoll CS, Barry ME, Ryan AG, et al. 10-Year Clinical Review of Revision Hip Arthroplasty Following Previous Metal on Metal Hip Procedures With Preoperative Magnetic Resonance Imaging and Metal Ion Analysis: Abductor Tendon Avulsion Predicts Dislocation. J Arthroplasty. 2025. PMID: 40349860. doi:10.1016/j.arth.2025.04.082
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。