文献速递关节外科

带干骺端套袖的翻修全膝关节置换术中股骨柄尺寸对影像学与临床结果的影响:一项回顾性分析

Influence of Stem Dimensions on Radiological and Clinical Results in Revision Knee Arthroplasty With Metaphyseal Sleeves: A Retrospective Analysis.
PubMed 文献 · J Arthroplasty · 2025-05-09

这项回顾性研究纳入67例使用非骨水泥带柄干骺端套袖行翻修全膝关节置换术的患者,随访至少2年,评估影像学与功能结局及其与股骨柄长度和髓腔填充比(CFR)的相关性。结果显示胫骨CFR与膝关节学会评分功能分呈弱但显著相关(r=0.270,P=0.031),对线正确者胫骨CFR和柄长度显著更高,但CFR或柄长度与影像学评分无相关性。作者认为联合使用干骺端套袖时压配柄可能并非实现充分假体稳定所必需。

要点

  • 对线正确者胫骨CFR 69.2% vs 对线不良者56.5%(P=0.049),柄长度97.7 vs 67.5 mm(P=0.029)。
  • 胫骨CFR与膝关节学会评分功能分呈弱但显著相关(r=0.270,P=0.031)。
  • 股骨和胫骨假体透亮线发生率分别为23.4%和44.8%,无假体松动病例。

核心结论

  • 联合使用干骺端套袖时,压配柄可能并非实现充分假体稳定所必需。
  • 胫骨柄尺寸似乎影响下肢力线,并可能轻度改善功能结局。

研究设计与样本

  • 回顾性研究,纳入67例使用非骨水泥带柄干骺端套袖行翻修全膝关节置换术的患者,随访至少2年。

主要发现

  • 股骨和胫骨组件平均CFR分别为64±12%和68.4±12.1%。
  • 股骨假体透亮线发生率为23.4%,胫骨假体为44.8%,无假体松动病例。
  • 平均髋-膝-踝角为178±2.93º,94%的患者在3º内翻-外翻范围内。
  • 对线正确者胫骨CFR 69.2% vs 对线不良者56.5%(P=0.049),柄长度97.7 vs 67.5 mm(P=0.029)。
  • 胫骨CFR与膝关节学会评分功能分呈弱但显著相关(r=0.270,P=0.031)。

关键数值与推荐

  • CFR或柄长度与改良膝关节学会全膝关节置换术影像学评估与评分系统评分之间无相关性。
  • 所有患者功能结局均显著改善。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Metaphyseal sleeves (MSs) achieve press-fit fixation in zone 2 during revision total knee arthroplasty (rTKA). The Canal Filling Ratio (CFR) estimates the engagement offered by a stem. The objectives in this study were to evaluate clinical and radiological outcomes in patients undergoing rTKA using stemmed MSs and to determine if there is a correlation between these variables and stem length and CFR. METHODS: This retrospective study included 67 patients who underwent rTKA using uncemented stemmed MSs, with a minimum follow-up of 2 years. The radiological outcomes included the stem length and CFR, the incidence of radiolucent lines for each sleeve, measured by the modified Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System for MSs, and limb alignment, measured by hip-knee-ankle angle. Functional outcomes comprised the Knee Society Score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Numerical Rating Scale for pain. RESULTS: The mean CFR for femoral and tibial components was 64 ± 12 and 68.4 ± 12.1%, respectively. Radiolucencies were observed in 23.4% of femoral and 44.8% of tibial implants, with no cases of prosthetic loosening. The mean hip-knee-ankle angle was 178 ± 2.93º, with 94% of the patients within 3º varus-valgus. Patients who were correctly aligned had a significantly higher tibial CFR (69.2 versus 56.5%, respectively, P = 0.049) and stem length (97.7 versus 67.5 mm, respectively, P = 0.029). No correlation was found between CFR or stem length and modified Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System scores. Functional outcomes improved significantly in all patients. Tibial CFR showed a weak, but significant correlation (r = 0.270) with Knee Society Score function (P = 0.031). CONCLUSIONS: Press-fit stems may not be necessary to achieve adequate implant stability when used in combination with an MS, but tibial stem dimensions seem to influence limb alignment and could slightly improve functional outcomes.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Ferrer-Banus M, Sabater-Martos M, Monfort-Mira M, et al. Influence of Stem Dimensions on Radiological and Clinical Results in Revision Knee Arthroplasty With Metaphyseal Sleeves: A Retrospective Analysis. J Arthroplasty. 2025. PMID: 40349876. doi:10.1016/j.arth.2025.05.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。