文献速递关节外科

全髋关节置换术后模块化双动衬垫的血清金属离子水平:按年限与植入物制造商的比较

Serum Metal Ion Levels in Modular Dual Mobility Liners After Total Hip Arthroplasty: A Comparison by Years and Implant Manufacturers.
PubMed 文献 · J Arthroplasty · 2025-05-09

这项回顾性研究纳入165例使用模块化双动衬垫行全髋关节置换术的患者,通过一次性抽血检测血清钴、铬、锆水平,并按植入年限分组比较。中位钴和铬均为0.3 mcg/L,13例(7.9%)金属离子异常升高,锆均检测不到;植入2年内中位钴水平较高(0.4 mcg/L)且数值范围更大(P < 0.001)。作者建议对模块化双动植入物进行金属离子水平的纵向追踪。

要点

  • 中位血清钴和铬水平均为0.3 mcg/L,锆在所有患者中均检测不到。
  • 13例(7.9%)金属离子异常升高:植入物A 10例(13%)、B 2例(4%)、C 1例(3%)。
  • 植入2年内中位钴水平较高(0.4 mcg/L)且范围更大(P < 0.001)。

核心结论

  • 植入2年内钴水平范围更大,随后各时间段变异性降低,可能提示双动结构存在初期「沉降期」,但需对个体患者连续抽血确认该趋势。
  • 作者建议对模块化双动植入物的金属离子水平进行纵向追踪。

研究设计与样本

  • 回顾性研究,纳入165例使用模块化双动衬垫行全髋关节置换术的患者。
  • 通过一次性抽血检测血清钴、铬、锆水平,按植入年限分为1至2年、2至5年、5至8年和8年以上组。

主要发现

  • 中位血清钴和铬水平分别为0.3(范围0.2至7)和0.3(范围0至3.1)mcg/L。
  • 13例(7.9%)金属离子水平异常升高:植入物A 10例(13%)、植入物B 2例(4%)、植入物C 1例(3%)。
  • 锆水平在所有患者中均检测不到。
  • 植入2年内中位钴水平为0.4 mcg/L,高于其他时间段且数值范围更大(P < 0.001)。
  • 随时间推移,各连续时间段的钴值范围逐渐减小。

关键数值与推荐

  • 钴参考值< 1.5 mcg/L、铬参考值< 1.2 mcg/L视为正常范围内。

临床怎么用

  • 作者建议对模块化双动植入物的金属离子水平进行纵向追踪。

局限性

  • 本研究为回顾性研究。
  • 采用一次性抽血检测,需对个体患者连续抽血以确认趋势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Modular dual-mobility (DM) liners are commonly used in total hip arthroplasty (THA) to decrease the risk of instability. However, there are concerns about accelerated wear, corrosion, and metal ion release in modular DM constructs. This study aimed to investigate serum metal ion levels over time after THA and evaluate any differences between implant manufacturers. METHODS: This retrospective study enrolled 165 patients who underwent THA with a modular DM liner. Serum cobalt (Co), chromium (Cr), and zirconium (Zr) levels were assessed via a one-time blood draw. Patients were grouped into time cohorts of one to 2, 2 to 5, 5 to 8, and 8+ years based on years since DM placement. The primary outcome was serum Co, Cr, and Zr levels. Reference values of < 1.5 mcg/L for Co and < 1.2 mcg/L for Cr were considered within normal limits. RESULTS: Median Co and Cr levels were 0.3 (range, 0.2 to 7) and 0.3 (range, 0 to 3.1) mcg/L, respectively. There were 13 patients (7.9%) who had abnormally elevated metal ion levels; 10 received implant A (13%), two received implant B (4%), and one received implant C (3%). The Zr levels were undetectable in all patients. Median Co levels (0.4 mcg/L) were higher within 2 years of DM implantation and had a greater range of values than other time periods (P < 0.001). Successive time periods displayed a decreased range of Co values over time. CONCLUSIONS: There was a greater range of Co levels within 2 years of implantation, which reduced in variability over successive time periods. Although this could suggest an initial "settling-in" period of DM constructs, sequential blood draws from individual patients over time are needed to confirm such trends. Longitudinal tracking of metal-ion levels over time in modular DM implants is recommended.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Parikh N, Lam AD, Waren D, et al. Serum Metal Ion Levels in Modular Dual Mobility Liners After Total Hip Arthroplasty: A Comparison by Years and Implant Manufacturers. J Arthroplasty. 2025. PMID: 40349877. doi:10.1016/j.arth.2025.05.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。