文献速递关节外科

术中直接超声振荡与常规超声振荡在假体周围关节感染诊断中的比较:液体培养诊断准确性与阳性时间对比

Intraoperative Direct Sonication Versus Conventional Sonication in the Diagnosis of Periprosthetic Joint Infection: Comparison of Diagnostic Accuracy and Time to Positivity of Fluid Culture.
PubMed 文献 · J Bone Joint Surg Am · 2025-05-13

该回顾性研究纳入2017年7月至2023年6月期间接受翻修、清创保留假体或切除术的415例患者(266例假体周围关节感染,149例无菌性松动),比较术中直接超声振荡与常规超声振荡的病原体培养诊断准确性和阳性时间。结果显示直接超声振荡敏感性88%高于常规69%(p<0.001),特异性84%与93%无显著差异(p=0.105),革兰阳性菌阳性时间缩短。

要点

  • 术中直接超声振荡敏感性88%高于常规超声振荡69%(p<0.001),特异性84%与93%无显著差异(p=0.105)。
  • 仅软组织直接超声振荡敏感性80%高于仅假体直接超声振荡75%。
  • 革兰阳性菌阳性时间:软组织直接超声中位2.12天、假体直接超声中位2.02天,均短于常规超声2.92天(p=0.003和p<0.001)。

核心结论

  • 术中直接超声振荡在假体周围关节感染微生物诊断中敏感性高于常规超声振荡,并略微缩短微生物阳性时间。

研究设计与样本

  • 回顾性研究,纳入2017年7月至2023年6月期间诊断为假体周围关节感染或无菌性松动并接受翻修、清创抗生素和假体保留或切除术且使用任一种超声振荡方法的患者,共415例,其中假体周围关节感染266例、无菌性松动149例。
  • 自2021年8月起采用术中直接超声振荡:将取出的假体和邻近软组织在小金属容器中直接超声振荡,然后在层流手术室中将超声振荡液接种于血培养瓶。
  • 常规超声振荡持续至2021年7月,包括涡旋混合30秒、超声振荡5分钟、再涡旋混合30秒,参照Trampuz等2007年描述的方法。

主要发现

  • 术中直接超声振荡液体培养敏感性88%,常规超声振荡69%(p<0.001)。
  • 术中直接超声振荡液体培养特异性84%,常规超声振荡93%(p=0.105)。
  • 仅软组织直接超声振荡敏感性80%,仅假体直接超声振荡75%。
  • 软组织与假体直接超声振荡培养结果不一致55例(软组织和假体均阳性28例、仅软组织阳性17例、仅假体阳性10例)。
  • 革兰阳性菌阳性时间:软组织直接超声振荡中位2.12天(四分位距1.40至3.16天),假体直接超声振荡中位2.02天(四分位距1.08至3.04天),常规超声振荡中位2.92天(四分位距1.83至3.96天)(p=0.003和p<0.001)。

局限性

  • 证据等级为诊断性研究III级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Conventional sonication is a recommended method in the diagnosis of periprosthetic joint infection (PJI), but the accuracy of diagnosis is still not ideal. We have applied the use of a handheld ultrasonic device and the intraoperative direct sonication of prostheses and soft tissues retrieved during surgery to improve the efficacy of the microbiological diagnosis of PJI and the incubation time of pathogens. METHODS: This was a retrospective study of patients diagnosed with PJI or aseptic loosening who underwent revision, DAIR (debridement, antibiotics, and implant retention), or resection, and for whom either sonication method was used between July 2017 and June 2023. Starting in August 2021, the removed implants and adjacent soft tissue were directly sonicated in a small metal container, and then the sonication fluid was incubated in blood culture bottles in the operating room under laminar air flow. Conventional sonication was continued through July 2021, and included vortex mixing for 30 seconds, sonication for 5 minutes, and additional vortex mixing for 30 seconds, as described by Trampuz et al. in 2007. The sensitivity, specificity, and time to positivity (TTP) of pathogen cultures were compared between intraoperative direct sonication and conventional sonication. RESULTS: Of the 415 included patients, 266 had PJI and 149 had aseptic loosening. Fluid from intraoperative direct sonication and conventional sonication showed sensitivities of 88% and 69% (p < 0.001) and specificities of 84% and 93% (p = 0.105), respectively. Higher sensitivity was obtained by intraoperative direct sonication of only soft tissue than by direct sonication of only the prosthesis (80% versus 75%). Culture results from intraoperative direct sonication of soft tissue and the prosthesis were inconsistent in 55 cases (soft tissue plus prosthesis: 28 cases, soft tissue only: 17 cases, and prosthesis only: 10 cases). Gram-positive organisms grew significantly faster following direct sonication (median TTP for soft-tissue, 2.12 days [interquartile range (IQR), 1.40 to 3.16 days], and median TTP for the prosthesis, 2.02 days [IQR, 1.08 to 3.04 days]) compared with conventional sonication (median TTP, 2.92 days [IQR, 1.83 to 3.96 days]) (p = 0.003 and p < 0.001, respectively). CONCLUSIONS: Intraoperative direct sonication was more sensitive than conventional sonication for the microbiological diagnosis of PJI and slightly shortened the TTP of microorganisms. LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Li Y, Wang F, Wahafu T, et al. Intraoperative Direct Sonication Versus Conventional Sonication in the Diagnosis of Periprosthetic Joint Infection: Comparison of Diagnostic Accuracy and Time to Positivity of Fluid Culture. J Bone Joint Surg Am. 2025. PMID: 40359254. doi:10.2106/JBJS.24.00744

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。