在髋臼翻修时同期植入现代髋臼组件与约束性髋臼内衬
回顾性分析2000至2021年38例在全髋关节翻修术中同期将约束性髋臼内衬(CAL)置入现代髋臼组件的病例,均辅以螺钉固定(平均4枚)。5年无无菌性松动翻修生存率为97%,无任何髋臼翻修生存率为94%,无任何翻修生存率为77%;仅1例因无菌性松动翻修。作者认为在髋臼组件稳定且螺钉固定牢靠时,翻修同期使用CAL的无菌性松动率低。
要点
- 38例翻修全髋中同期置入CAL与现代髋臼组件,平均随访4年。
- 5年无无菌性松动髋臼翻修生存率97%,无任何翻修生存率77%。
- 仅1例因无菌性松动翻修,未翻修病例影像学未见髋臼组件松动。
核心结论
- 在髋臼翻修时选择性使用CAL并配合现代髋臼组件与多枚螺钉固定,无菌性松动率低。
- 作者认为当植入稳定的髋臼组件并辅以牢靠螺钉固定时,可在髋臼翻修同期使用CAL。
研究设计与样本
- 回顾性分析本机构全关节登记系统2000至2021年数据,纳入38例在全髋关节翻修术中同期将CAL置入现代髋臼组件的病例。
- 所有病例均接受补充螺钉固定,平均4枚螺钉;翻修时平均年龄66岁,女性占74%,平均体重指数31。
- 翻修最常见指征为复发性脱位(57%)、无菌性松动(20%)和二期再植入(26%);平均随访4年。
主要发现
- 5年无因无菌性松动行髋臼再翻修生存率为97%,无任何髋臼再翻修生存率为94%,无任何再翻修生存率为77%。
- 仅1例髋臼组件在2年时因无菌性松动行翻修。
- 共8例再翻修,原因分别为脱位(4例)、假体周围关节感染(2例)、无菌性松动(1例)和假体周围骨折(1例)。
- 影像学复查未在未翻修病例中发现髋臼组件松动的证据。
临床怎么用
- 作者认为在髋臼翻修时,若植入稳定的髋臼组件并辅以牢靠螺钉固定,可同期使用CAL。
局限性
- 证据等级为IV级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Concern for early acetabular component loosening may deter surgeons from using a constrained acetabular liner (CAL) at the time of acetabular component revision. We have previously demonstrated this can be safely and effectively done with a highly porous tantalum shell, numerous screws, and a cemented constrained liner. It is not known, however, whether similar outcomes are achievable with contemporary modular acetabular components with a liner-locking mechanism. METHODS: A retrospective review of our total joint registry from 2000 to 2021 identified 38 cases of revision total hip arthroplasties (THAs) in which a CAL was inserted into a contemporary revision acetabular component placed during the same surgery. All cases received supplemental screw fixation (mean of four screws). The mean age at revision THA was 66 years, 74% of patients were women, and the mean body mass index was 31. The most common indications for index revision THA were recurrent dislocation (57%), aseptic loosening (20%), and two-stage reimplantation (26%). The mean follow-up was 4 years. RESULTS: The 5-year survivorship free from acetabular rerevision for aseptic loosening was 97%, any acetabular rerevision was 94%, and any rerevision was 77%. There was only one acetabular component revised for aseptic loosening at 2 years. There were eight re-revisions performed for dislocation (4), periprosthetic joint infection (2), aseptic loosening (1), and periprosthetic fracture (1). Radiographic review did not identify any evidence of acetabular component loosening in unrevised cases. CONCLUSIONS: Selective use of a CAL at the time of acetabular revision with a contemporary acetabular component and multiple screws had a low rate of aseptic loosening. These results suggest that a CAL can be utilized at the time of acetabular revision when a stable acetabular component is inserted with robust screw fixation. LEVEL OF EVIDENCE: Level IV.
引用
- Hayden AC, Gonzalez-Bravo AE, Markos JR, et al. Constrained Acetabular Liners Implanted Simultaneously at the Time of Acetabular Revision Using Contemporary Components. J Arthroplasty. 2025. PMID: 40383166. doi:10.1016/j.arth.2025.05.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。