不同固定方法对股骨远端假体生存率的比较
该回顾性单机构队列研究纳入243例股骨远端假体(DFR),比较骨水泥固定、非骨水泥固定及骨水泥联合股骨锥固定的翻修率与假体生存率。结果显示三组翻修率(29.4% vs 13.3% vs 23.1%)及翻修原因均无显著差异,5年生存率分别为72%、87%、77%。作者结论认为固定方法未显著影响翻修率或原因。
要点
- 三组DFR翻修率无显著差异:骨水泥组29.4%、非骨水泥组13.3%、骨水泥联合股骨锥组23.1%(P=0.16)。
- 翻修原因(无菌性松动、假体周围感染、假体周围骨折、软组织失败)组间无显著差异(P=0.97)。
- 5年生存率:骨水泥组72%、非骨水泥组87%、骨水泥联合股骨锥组77%。
核心结论
- 在该回顾性队列中,DFR固定方法未显著影响翻修率或翻修原因;本研究样本量大于同类分析。
研究设计与样本
- 回顾性单机构队列研究,纳入因全膝关节置换翻修或原生股骨远端骨折行DFR的患者243例:骨水泥固定187例、非骨水泥固定30例、骨水泥联合股骨锥固定26例。
主要发现
- 至末次随访,骨水泥组55例(29.4%)、非骨水泥组4例(13.3%)、骨水泥联合股骨锥组6例(23.1%)需翻修(P=0.16)。
- 翻修原因包括无菌性松动、假体周围感染、假体周围骨折和软组织失败,组间无显著差异(P=0.97)。
- 股骨松动是翻修的主要原因:骨水泥组8例(14.5%)、非骨水泥组1例(25.0%)、骨水泥联合股骨锥组1例(16.7%)翻修DFR(P=0.62)。
- 骨水泥组、非骨水泥组和骨水泥联合股骨锥组的5年生存率分别为72%、87%和77%。
关键数值与推荐
- DFR翻修率:骨水泥组29.4% vs 非骨水泥组13.3% vs 骨水泥联合股骨锥组23.1%(P=0.16)。
- 翻修原因组间比较P=0.97。
- 股骨松动致翻修比例:骨水泥组14.5% vs 非骨水泥组25.0% vs 骨水泥联合股骨锥组16.7%(P=0.62)。
- 5年生存率:骨水泥组72% vs 非骨水泥组87% vs 骨水泥联合股骨锥组77%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Distal femoral replacements (DFRs) are utilized in primary and revision total knee arthroplasty in the setting of segmental femoral bone loss, but they are known to have high failure rates. This study aimed to examine DFR survival by fixation method to determine if the use of cemented fixation or a femoral cone may decrease the risk of aseptic loosening and all-cause revision. METHODS: This study was a retrospective, single-institution cohort study of patients who underwent DFR for revision total knee arthroplasty or native distal femoral fracture. Patient demographic and surgical data were collected via chart review, and the fixation method was determined using operative notes and radiographs. Patients were divided into cohorts by DFR fixation method: cemented, cementless, and cemented with a femoral cone. Outcomes of interest included revision rates, revision causes, and DFR survival by fixation method. We identified 243 DFRs for study inclusion: 187 cemented, 30 cementless, and 26 cemented with femoral cone. No significant differences were seen among groups for indication of primary DFR (P = 0.54). RESULTS: By the last follow-up, 55 (29.4%) cemented, four (13.3%) cementless, and six (23.1%) cemented with femoral cone DFRs had required revision (P = 0.16). Causes of revision, including aseptic loosening, periprosthetic joint infection, periprosthetic fracture, and soft tissue failure, were not significantly different among groups (P = 0.97). Femoral loosening was the primary cause of revision in eight (14.5%) cemented, one (25.0%) uncemented, and one (16.7%) cemented with femoral cone revised DFRs (P = 0.62). The 5-year survival rates for cemented, uncemented, and cemented with femoral cone were 72, 87, and 77%, respectively. CONCLUSIONS: In our retrospective cohort, the method of DFR fixation did not significantly affect rates or causes of revision. This study represents a larger sample of DFRs than comparable analyses.
引用
- Hohmann AL, Parikh N, Leipman JH, et al. Comparison of Survivorship of Distal Femoral Replacements by the Fixation Method. J Arthroplasty. 2025. PMID: 40381964. doi:10.1016/j.arth.2025.05.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。