三维打印一体化髋臼假体在全髋关节置换术治疗髋关节发育不良中的应用

Application of Three-Dimensional Printing Integrated Acetabular Prosthesis In the Treatment of Hip Dysplasia In Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2025-05-12

回顾性分析85例(106髋)Crowe I至IV型髋关节发育不良行全髋关节置换术的患者,采用三维打印一体化髋臼假体,术后随访26.8个月。双侧垂直旋转中心差异从14.5±13.8 mm降至3.8±3.7 mm,水平差异从11.4±7.7 mm降至2.0±2.2 mm,Harris髋关节评分从术后3个月82.6±5.7分升至末次随访90.4±3.3分,早期临床疗效满意。

要点

  • 三维打印多孔钽一体化髋臼假体用于Crowe I-IV型DDH全髋置换,术后旋转中心恢复良好。
  • 双侧垂直旋转中心差异从14.5±13.8 mm降至3.8±3.7 mm,水平差异从11.4±7.7 mm降至2.0±2.2 mm。
  • Harris髋关节评分术后3个月82.6±5.7分,末次随访90.4±3.3分,早期疗效满意。

核心结论

  • 使用三维打印多孔钽一体化髋臼假体行全髋关节置换术治疗各型DDH,能充分保证髋臼覆盖,精确恢复髋关节旋转中心,有助于髋关节功能恢复,早期临床疗效满意。

研究设计与样本

  • 回顾性分析85例(106髋)Crowe I至IV型DDH患者,均在大连大学附属中山医院骨科行全髋关节置换术,术后随访26.8个月(范围16.5至31.8)。
  • 为每个Crowe分型设计并打印一系列一体化髋臼假体,测量并比较术前术后双侧水平旋转中心差异和垂直旋转中心差异,测量髋臼杯外倾角和前倾角。
  • 术后3个月和末次随访时分别采用Harris髋关节评分和SF-36问卷评估髋关节功能与生活质量。

主要发现

  • 双侧垂直旋转中心差异从14.5±13.8 mm降至3.8±3.7 mm。
  • 双侧水平旋转中心差异从11.4±7.7 mm降至2.0±2.2 mm。
  • 髋臼杯外倾角和前倾角恢复满意。
  • Harris髋关节评分术后3个月为82.6±5.7分,末次随访为90.4±3.3分。
  • SF-36问卷术后3个月为625±45分,末次随访为748±32分。

关键数值与推荐

  • 双侧垂直旋转中心差异术前14.5±13.8 mm,术后3.8±3.7 mm。
  • 双侧水平旋转中心差异术前11.4±7.7 mm,术后2.0±2.2 mm。
  • Harris髋关节评分术后3个月82.6±5.7分,末次随访90.4±3.3分。
  • SF-36问卷术后3个月625±45分,末次随访748±32分。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of our study was to investigate the clinical efficacy of a three-dimensional printed integrated acetabular prosthesis (IAP) in total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) with different Crowe types. METHODS: A total of 85 patients (106 hips) who had DDH (Crowe types I to IV) and who underwent THA at the Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, were retrospectively analyzed. All the operations were successfully completed, and the postoperative follow-up time was 26.8 months (range, 16.5 to 31.8). A series of IAPs was designed and printed for each Crowe type. The bilateral horizontal center of rotation difference and the bilateral vertical center of rotation difference before and after operation were measured and compared. Cup inclination and anteversion angle were measured. The Harris Hip Score and the Short Form 36 questionnaire were used to evaluate hip function and quality of life, respectively, at 3 months after the operation and at the last follow-up. RESULTS: The bilateral vertical center of rotation difference decreased from 14.5 ± 13.8 to 3.8 ± 3.7 mm, and the bilateral horizontal center of rotation difference decreased from 11.4 ± 7.7 to 2.0 ± 2.2 mm. The cup inclination and anteversion angle have been satisfactorily restored. The Harris Hip Score was 82.6 ± 5.7 points at 3 months after the operation and 90.4 ± 3.3 points at the last follow-up. The Short Form 36 questionnaire was 625 ± 45 points at 3 months after the operation and 748 ± 32 points at the last follow-up. CONCLUSIONS: The use of three-dimensional-printed porous tantalum IAP in THA in the treatment of various types of DDH can fully ensure the acetabulum's coverage, accurately restoring the rotation center of the hip, which is helpful for the recovery of hip joint function. The early clinical efficacy is satisfactory.