羟基磷灰石涂层髋臼杯在初次全髋关节置换术中的Meta分析
该Meta分析检索Medline、Embase和Cochrane图书馆至2024年11月,纳入比较初次全髋关节置换术中羟基磷灰石(HA)涂层与非HA涂层髋臼杯的随机对照试验。结果显示HA涂层杯的放射透亮线显著更少(P<0.00001),而Harris髋关节评分、骨内膜骨形成、线性磨损率、因无菌性松动行髋臼组件翻修及异位骨化均无显著差异。作者据此认为初次全髋关节置换术中应优先选用HA涂层髋臼杯。
要点
- HA涂层髋臼杯的放射透亮线显著少于非HA涂层杯(P<0.00001)。
- Harris髋关节评分、骨内膜骨形成、线性磨损率、无菌性松动翻修及异位骨化两组无显著差异。
- 作者认为初次全髋关节置换术中应优先选用HA涂层髋臼杯。
核心结论
- Meta分析显示初次全髋关节置换术中HA涂层髋臼杯的放射透亮线显著少于非HA涂层杯。
- HA涂层杯在Harris髋关节评分、骨内膜骨形成、线性磨损率、髋臼组件翻修及异位骨化方面未显示优于非HA涂层杯。
- 作者认为初次全髋关节置换术中应优先选用HA涂层髋臼杯而非非HA涂层髋臼杯。
研究设计与样本
- 按照PRISMA指南检索Medline、Embase和Cochrane图书馆,检索截至2024年11月。
- 纳入比较初次全髋关节置换术中HA涂层髋臼杯与非HA涂层杯的随机对照试验。
主要发现
- HA涂层杯患者的放射透亮线显著更少(P<0.00001)。
- Harris髋关节评分两组无显著差异(P=0.20)。
- 骨内膜骨形成两组无显著差异(P=0.23)。
- 线性磨损率两组无显著差异(P=0.44)。
- 因无菌性松动行髋臼组件翻修两组无显著差异(P=0.29);异位骨化两组无显著差异(P=0.71)。
临床怎么用
- 作者认为初次全髋关节置换术中应优先选用HA涂层髋臼杯而非非HA涂层髋臼杯。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cementless fixation is the predominant method used in primary total hip arthroplasties (THAs) performed in the United States, with porous and hydroxyapatite (HA)-coated implants used most commonly. Preclinical studies have demonstrated that HA-coated implants achieve superior fixation and stability compared to those with porous surfaces alone, yet the adoption of HA coating in clinical practice has been inconsistent. There have been few previous meta-analyses comparing HA-coated versus non-HA-coated acetabular cups. We hypothesized that HA-coated acetabular cups would result in a reduced incidence of revisions compared to non-HA-coated cups, with no difference in osteolysis, radiolucent lines, or patient-reported outcomes. METHODS: Medline, Embase, and Cochrane libraries were searched through November 2024 according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The studies included were randomized controlled trials comparing HA-coated acetabular cups to non-HA-coated cups in primary THA. Outcomes included Harris Hip Score (HHS), endosteal bone formation, radiolucent lines, linear wear rate, revision for aseptic loosening, and heterotopic ossification. RESULTS: There were significantly fewer radiolucent lines (P < 0.00001) for patients who had HA-coated cups. There was no significant difference in HHS (P = 0.20), endosteal bone formation (P = 0.23), linear wear rate (P = 0.44), acetabular component revisions for aseptic loosening (P = 0.29), or heterotopic ossification (P = 0.71) between HA-coated and non-HA-coated cups. CONCLUSIONS: The results of our meta-analysis demonstrated that HA-coated acetabular cups in primary THA led to significantly fewer radiolucent lines than non-HA-coated cups. They did not show any advantage of HA-coated cups over non-HA-coated cups in terms of HHS, endosteal bone formation, linear wear rate, acetabular component revisions, or heterotopic ossification. These results suggest that HA-coated acetabular cups should be preferred over non-HA-coated acetabular cups in primary THA.
引用
- Thiel KN, Kim WT, Woodruff R, et al. Hydroxyapatite-Coated Acetabular Cups in Primary Total Hip Arthroplasty: A Meta-Analysis. J Arthroplasty. 2025. PMID: 40348143. doi:10.1016/j.arth.2025.04.050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。