全膝关节置换术后伸膝装置同种异体移植重建翻修术的临床结局不佳
回顾性纳入2018年11月至2023年8月间17例因既往伸膝装置同种异体移植(EMA)失败而行翻修EMA重建的患者,平均年龄67岁,其中10例为女性。17例翻修EMA中13例失败,10例需再手术,8例最终改为第三次EMA。作者结论认为第二次翻修EMA失败率高、临床结局差,与移植物整合失败、早期机械性失败及慢性假体周围感染相关;对于肢体条件差的患者,支具可能是最佳替代方案。
要点
- 17例翻修EMA重建中13例失败,10例需再次手术。
- 5例因慢性假体周围感染翻修,均行二期置换方案。
- 8例最终改为第三次EMA重建。
核心结论
- 第二次翻修EMA重建失败率高且临床结局差,与同种异体移植物整合失败、早期机械性移植物失败及慢性假体周围感染相关。
- 作者认为需要替代的伸膝装置重建技术;对于肢体条件差的患者,支具可能是最佳替代方案。
研究设计与样本
- 回顾性分析2018年11月至2023年8月间连续病例系列中17例翻修EMA重建,随访至2023年8月。
- 所有EMA重建均使用来自Musculoskeletal Transplant Foundation的新鲜冷冻、未经辐照的同种异体移植物。
- 纳入标准为既往EMA重建失败、无感染、存在功能性障碍且临床有跌倒;按McPherson宿主和肢体评分分级。
- 17例患者中10例为女性,平均年龄67岁;10例为A宿主(未受损),14例肢体评分为3分(高度受损)。
- 证据等级为4级,为连续病例系列的回顾性 review。
主要发现
- 17例翻修EMA中13例失败,其中10例接受了额外手术。
- 3例临床失败者KOOS JR.评分<63.7分,5例存在>30°的伸直滞后。
- 3例因机械性EMA失败(撕裂/断裂)翻修。
- 5例因慢性假体周围感染翻修,均接受二期置换方案。
- 8例最终改为第三次EMA重建。
关键数值与推荐
- 临床失败定义为KOOS JR.评分<63.7分。
- 伸直滞后>30°被记录为临床失败表现之一。
- McPherson宿主评分:10例为A宿主(未受损);肢体评分:14例为3分(高度受损)。
临床怎么用
- 作者认为第二次翻修EMA重建失败率高、临床结局差,需要替代的伸膝装置重建技术。
- 作者认为对于肢体条件差的患者,支具可能是最佳替代方案。
局限性
- 证据等级为4级,为连续病例系列的回顾性 review。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Extensor mechanism rupture following total knee arthroplasty is a formidable complication frequently limiting limb function. Multiple reconstruction techniques are described, but the extensor mechanism allograft (EMA) that is utilized for complex reconstruction has notable failure rates. Rarer is a second attempt at EMA reconstruction. The outcomes of these revised EMA reconstructions have not been well studied. We report our outcomes with a revised EMA procedure. METHODS: Revision EMA reconstructions performed between November 2018 and August 2023 were retrospectively reviewed. All EMA reconstructions utilized fresh-frozen, nonirradiated allografts from the Musculoskeletal Transplant Foundation. Inclusion criteria were a failed extensor reconstruction with a prior EMA, infection-free, and functional debility with clinical falling. Patients were graded according to the McPherson host and limb score. There were 17 revision EMA reconstructions performed in 17 patients, 10 of whom were women, who had a mean age of 67 years. There were 10 uncompromised A host and 14 who had a limb score of 3 (highly compromised). RESULTS: There were 13 revision EMAs that failed among the 17 reconstructions, 10 of which underwent additional operations. There were three considered clinical failures with a Knee Injury and Osteoarthritis Outcome Score, JR. score < 63.7 points, and five patients who had a lag > 30°. There were three patients who were revised for mechanical EMA failure (tear/rupture). There were five patients who were revised due to chronic periprosthetic joint infection with all undergoing a two-stage exchange protocol. There were eight patients who were eventually revised to a third EMA. CONCLUSIONS: A second revision EMA reconstruction exhibits high failure rates with poor clinical outcomes, related to failure of allograft incorporation, early mechanical allograft failure, and chronic periprosthetic joint infection. Alternative techniques for extensor reconstruction are needed. In patients who had a compromised limb, bracing may be the best alternative solution. LEVEL OF EVIDENCE: 4, Retrospective review of consecutive case series.
引用
- Mao YV, Wahle CF, Dipane MV, et al. Poor Clinical Outcomes Following Total Knee Arthroplasty-Associated Revisions of Extensor Mechanism Allograft Reconstructions. J Arthroplasty. 2025. PMID: 40381965. doi:10.1016/j.arth.2025.05.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。