定制3D打印导板在前交叉韧带重建中的应用:与传统技术的系统综述与Meta分析
该系统综述与Meta分析纳入4项随机对照试验和1项回顾性研究共299例患者,比较3D辅助前交叉韧带重建与传统手术的股骨隧道定位。3D组隧道定位时间显著更短(均数差-2.80分钟,95%CI -4.13至-1.46,P<.0001),隧道定位准确性显著更高(OR 4.62,95%CI 1.02至20.89,P=.05),术后Lysholm和IKDC功能评分无显著差异(P>.05)。
要点
- 3D导板组隧道定位时间较传统组显著缩短,均数差-2.80分钟(95%CI -4.13至-1.46,P<.0001)。
- 3D导板组隧道定位准确性显著高于传统组,OR 4.62(95%CI 1.02至20.89,P=.05)。
- 术后Lysholm和IKDC功能评分两组无显著差异(P>.05)。
核心结论
- 使用3D导板有助于缩短隧道定位时间并提高隧道定位准确性,术后功能结局相当。
研究设计与样本
- 系统综述与Meta分析,证据等级为3级,按照PRISMA指南检索MEDLINE、EMBASE和Cochrane对照试验中心注册库。
- 纳入比较3D辅助前交叉韧带重建与传统手术的随机对照试验和观察性研究,共4项随机对照试验和1项回顾性研究,合计299例患者。
主要发现
- 3D组隧道定位时间显著短于传统组,均数差-2.80分钟(95%CI -4.13至-1.46,P<.0001)。
- 3D组隧道定位准确性显著高于传统组,OR 4.62(95%CI 1.02至20.89,P=.05)。
- 术后Lysholm和IKDC功能评分两组无显著差异(P>.05)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Accurate femoral tunnel positioning is essential for successful anterior cruciate ligament (ACL) reconstruction. Tunnel malposition can happen due to limited arthroscopic visibility as well as anatomic variance. The use of customized patient-specific guides can optimize surgical planning and enhance accuracy. PURPOSE: To compare femoral tunnel positioning in 3-dimensional (3D)-assisted ACL reconstruction versus conventional surgery. STUDY DESIGN: Systematic review and meta-analysis; Level of evidence, 3. METHODS: This systematic review and meta-analysis was performed in line with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines with a search of the following databases: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials. All randomized controlled trials (RCTs) and observational studies comparing the 2 interventions were included. Primary outcomes included tunnel positioning time (minutes) and accuracy rates (%). Secondary outcomes were Lysholm and International Knee Documentation Committee (IKDC) functional scores. Random effects modeling was used for analysis. RESULTS: Four RCTs and 1 retrospective study were included, enrolling a total of 299 patients. The 3D group had significantly shorter tunnel positioning times (mean difference, -2.80; 95% CI, -4.13 to -1.46; P < .0001) with significantly greater tunnel positioning accuracy (odds ratio, 4.62; 95% CI, 1.02 to 20.89; P = .05). No significant difference was noted in postoperative functional scores, including Lysholm and IKDC scores (P > .05). CONCLUSION: The use of 3D guides helps reduce tunnel positioning time and increases tunnel positioning accuracy with comparable postoperative functional outcomes.
引用
- Al-Naseem AO, Almehandi A, Ebrahim KM, et al. The Use of Customized 3D-Printed Guides in Anterior Cruciate Ligament Reconstruction Compared With Conventional Techniques: A Systematic Review and Meta-analysis. Am J Sports Med. 2025. PMID: 40072239. doi:10.1177/03635465251315165
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。