文献速递关节外科

印度患者下肢股四头肌向量与白种人和日本人相似

The Quadriceps Vector in the Lower Extremity of Indian Patients Is Similar in Caucasian and Japanese Patients.
PubMed 文献 · J Arthroplasty · 2025-03-15

该影像学研究对36例印度患者(女18例,平均年龄59岁;男18例,平均年龄61岁)行CT扫描测定三维股四头肌向量(QV),测量方法同既往研究。印度队列QV自髌骨顶点指向股骨颈,在股骨头的侧方30.8 mm(范围25.2至36.4)和前方31.2 mm(范围28.4至33.9)处通过;投影至冠状面时QV与球形轴最接近,夹角1.2±0.8°(P<0.05)。作者认为QV对线可能适用于大多数人类膝关节,无论形态如何。

要点

  • 印度队列QV自髌骨顶点指向股骨颈,与白种人和日本CT扫描结果一致。
  • 印度膝关节QV通过点位于股骨头侧方30.8 mm(范围25.2至36.4)、前方31.2 mm(范围28.4至33.9)。
  • 投影至冠状面时QV与球形轴最接近,夹角1.2±0.8°(P<0.05)。

核心结论

  • 与既往研究相同,在印度原生膝关节中QV经股骨头侧方穿过股骨颈,且投影至冠状面时与球形轴(股骨头中心至球形内侧髁中心)最平行。
  • 这些数据提示,使用QV进行对线可能适用于大多数人类膝关节,无论形态如何。

研究设计与样本

  • 影像学研究,使用CT扫描测定印度队列36例患者(女18例,平均年龄59岁;男18例,平均年龄61例)的QV,测量方法同既往研究。
  • 将QV及所有测量轴在队列内进行比较。

主要发现

  • 印度队列QV自髌骨顶点指向股骨颈,与白种人和日本CT扫描结果一致。
  • 印度膝关节QV通过点位于股骨头侧方30.8 mm(范围25.2至36.4)、前方31.2 mm(范围28.4至33.9)。
  • 投影至冠状面时QV与球形轴最接近,夹角1.2±0.8°(P<0.05)。

关键数值与推荐

  • 印度队列QV通过点:股骨头侧方30.8 mm(范围25.2至36.4),前方31.2 mm(范围28.4至33.9)。
  • 投影至冠状面时QV与球形轴夹角1.2±0.8°(P<0.05)。

临床怎么用

  • 作者认为,使用QV进行对线可能适用于大多数人类膝关节,无论形态如何。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Correct alignment of knee components contributes to the longevity and function of total knee arthroplasty. The accuracy and reliability of calculating the three-dimensional quadriceps vector (QV) using computed tomography (CT) scans in Caucasian and Japanese study participants have been established in previous studies. In all cases, the QV was directed from the top of the patella to the middle of the femoral neck. The literature describes considerable differences in the morphology of bone in the lower extremities of Indian people compared with that of Caucasian and Japanese people. METHODS: An imaging study was conducted using CT scans to determine the QV in a cohort of 36 patients from India (18 women [mean age 59 years], 18 men [mean age 61 years]). The same measurement methods were used for this cohort as in previous studies. The QV and all measured axes were compared within the cohort. RESULTS: The QV for the Indian cohort was found to be directed from the top of the patella toward the femoral neck, as in Caucasian and Japanese CT scans. In the Indian knees, the passing point of the vector was found to be lateral 30.8 mm (range, 25.2 to 36.4) and anterior 31.2 mm (range, 28.4 to 33.9) to the femoral head. When projected to the coronal plane, the QV was closest to that of the spherical axis, 1.2 ± 0.8° (P < 0.05). CONCLUSIONS: As in previous studies, the QV crosses the femoral neck lateral to the femoral head and is most parallel to the spherical axis (center femoral head to center spherical medial condyle) projected onto the coronal plane in the native Indian knee. These data suggest that using the QV for alignment may be applied to most human knees regardless of morphology.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Chi F, Takagi S, Mochizuki T, et al. The Quadriceps Vector in the Lower Extremity of Indian Patients Is Similar in Caucasian and Japanese Patients. J Arthroplasty. 2025. PMID: 40097120. doi:10.1016/j.arth.2025.03.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。