文献速递关节外科

双锥度骨水泥柄线性骨水泥技术至少10年结局:有领与无领柄的比较研究

Minimum 10-Year Outcomes of Double-Tapered Cemented Stems With Line-To-Line Cementing: A Comparative Study of Collared and Collarless Stems.
PubMed 文献 · J Arthroplasty · 2025-03-19

这项回顾性比较研究纳入1996至2011年单机构单术者282例连续初次全髋关节置换(244例患者),比较两种骨水泥柄采用线性骨水泥技术的至少10年临床与影像学结局。两组髋关节功能结局与并发症率无显著差异,10年任何翻修生存率A组97.0%(95%CI 93.6至99.6)对B组99.0%(95%CI 94.6至99.9)(P=0.279),两组因无菌性松动翻修生存率均为100%。B组柄下沉更多(P<0.001),两组皮质肥大发生率分别为28.9%和19.8%,受累患者临床结局良好。

要点

  • 线性骨水泥技术两种骨水泥柄10年任何翻修生存率A组97.0%对B组99.0%(P=0.279)。
  • 两组因无菌性松动翻修生存率均为100%。
  • B组柄下沉较A组更多(P<0.001),皮质肥大发生率分别为28.9%和19.8%。

核心结论

  • 采用线性骨水泥技术的骨水泥柄10年临床与影像学结局优良,无需因无菌性松动进行翻修。

研究设计与样本

  • 回顾性比较研究,纳入1996至2011年单机构单术者282例连续初次全髋关节置换(244例患者),使用两种骨水泥柄类型,并进行临床与影像学评估及柄生存分析。

主要发现

  • 两组髋关节功能结局无显著差异,并发症率无显著差异。
  • 10年任何翻修生存率A组97.0%(95%CI 93.6至99.6)对B组99.0%(95%CI 94.6至99.9)(P=0.279)。
  • 两组因无菌性松动翻修生存率均为100%。
  • B组柄下沉较A组更多(P<0.001)。
  • 皮质肥大发生率两组分别为28.9%和19.8%,受累患者临床结局良好。

关键数值与推荐

  • 10年任何翻修生存率A组97.0%(95%CI 93.6至99.6),B组99.0%(95%CI 94.6至99.9),P=0.279。
  • 两组因无菌性松动翻修生存率均为100%。
  • 皮质肥大发生率两组分别为28.9%和19.8%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to evaluate the clinical and radiological outcomes of stems using the line-to-line technique with a minimum follow-up of 10 years. METHODS: A retrospective comparative study was conducted on 282 consecutive primary total hip arthroplasties (244 patients) using two cemented stem types at a single institution by a single surgeon from 1996 to 2011. Clinical and radiological assessments and stem survival analysis were performed. RESULTS: There were no significant differences in hip function outcomes or complication rates between the groups. The 10-year stem survival rate for any revision was 97.0% (95% CI [confidence interval]: 93.6 to 99.6) in stem group A and 99.0% (95% CI: 94.6 to 99.9) in stem group B, respectively (P = 0.279). Both groups had a 100% survival rate for aseptic loosening. Stem subsidence was more in stem group B (P < 0.001). Cortical hypertrophy occurred in 28.9 and 19.8% of the two groups, respectively, with good clinical outcomes in affected patients. CONCLUSIONS: The 10-year clinical and radiological outcomes for stems using the line-to-line technique were excellent, with no revisions required for aseptic loosening.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Terakawa H, Kawarai Y, Nakamura J, et al. Minimum 10-Year Outcomes of Double-Tapered Cemented Stems With Line-To-Line Cementing: A Comparative Study of Collared and Collarless Stems. J Arthroplasty. 2025. PMID: 40113184. doi:10.1016/j.arth.2025.03.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。