文献速递关节外科

一种利用常规双平面X线摄影测量膝关节内收力矩的新影像学方法:20例患者初步结果

A Novel Radiographic Methodology to Measure Knee Adduction Moment Using Routine Biplane Radiographs: Initial Results of 20 Patients.
PubMed 文献 · J Arthroplasty · 2025-03-11

研究纳入20例拟行全膝关节置换术患者,在术前和术后6周平地行走时进行运动分析,并同期在双足和单腿站立时采集与地面反作用力空间和时间同步的正位和侧位双平面X线片,计算影像学膝关节内收力矩(KAM),并与步行时动态峰值KAM及KOOS JR比较。结果示单腿站立时影像学KAM与动态峰值KAM强相关,但KAM与KOOS JR不相关。

要点

  • 单腿站立时影像学KAM与步行动态峰值KAM强相关。
  • KAM与KOOS JR不相关。
  • 该方法可在常规临床中评估膝关节动力学指标。

核心结论

  • 单腿站立时影像学KAM是步行动态峰值KAM的优秀替代指标。
  • KAM与KOOS JR不相关,但随访时间短且未考虑膝关节屈曲力矩等其他动力学指标。
  • 所提出的方法可在常规临床中评估功能恢复的膝关节动力学标志物,补充患者报告结局指标。

研究设计与样本

  • 对20例患者(9例女性,年龄38至76岁,体重指数22.1至31.6)在全膝关节置换术前和术后6周平地行走时进行运动分析。
  • 在同一时间点采集正位和侧位双平面X线片,并与双足和单腿站立患侧时的地面力测量在空间和时间上同步。

主要发现

  • 步行动态峰值KAM范围术前为-0.5至4.3 %BW·H,术后为1至4.4 %BW·H。
  • 静态KAM(尤其单腿站立时)与动态峰值KAM强相关。
  • KAM与KOOS JR不相关。

关键数值与推荐

  • KAM以体质量百分比乘以身高(%BW·H)表示,在冠状面计算为地面力与力的作用线至膝关节中心垂直距离的乘积。
  • 单腿站立时影像学KAM与步行动态峰值KAM强相关,但KAM与KOOS JR不相关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 随访时间短。
  • 未考虑膝关节屈曲力矩等其他动力学指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Compromised function is a common reason for patient dissatisfaction after total knee arthroplasty. However, objectively evaluating function often requires costly, time-consuming, and highly specialized data collection and analysis in a dedicated motion analysis laboratory. To overcome this practical barrier, we developed a radiographic-based method to quantify knee joint moments in routine clinical care and to explore the relationship between knee moments in the sagittal plane and the Knee Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR). METHODS: Motion analysis was performed on 20 patients (nine women, aged: 38 to 76 years; body mass index: 22.1 to 31.6) during level ground walking preoperatively and 6 weeks after total knee arthroplasty. At the same time points, patients underwent frontal and lateral biplane radiographs that were synchronized spatially and temporally with ground force measurements during bipedal and single leg stances on the operated leg. The knee adduction moment (KAM), in percent body weight times height (%BW·H), was calculated in the coronal plane as the product of the ground force and the perpendicular distance between the force's line of action and the knee center. The dynamic KAM during walking was compared to the radiographic KAM and related to KOOS JR. RESULTS: The peak dynamic KAM range was -0.5 to 4.3% BW·H preoperatively and 1 to 4.4% BW·H postoperatively. The static KAM, particularly during single leg stance, was strongly correlated with the peak dynamic KAM; however, the KAM was not correlated with KOOS JR. CONCLUSIONS: The radiographic KAM, particularly during single leg stance, was an excellent surrogate metric for the peak dynamic KAM. The KAM was not correlated with KOOS JR; however, our follow-up was short, and we did not consider additional kinetic metrics, like the knee flexion moment. The proposed methodology allows routine clinical evaluation of knee kinetic markers of functional recovery that can complement patient-reported outcome measures.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Quevedo Gonzalez FJ, Sculco PK, Karasavvidis T, et al. A Novel Radiographic Methodology to Measure Knee Adduction Moment Using Routine Biplane Radiographs: Initial Results of 20 Patients. J Arthroplasty. 2025. PMID: 40081603. doi:10.1016/j.arth.2025.03.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。