文献速递关节外科

初次全膝关节置换术中胫骨假体置于体质性内翻对线的5年生存率分析

Tibial Components Placed in Constitutional Varus Alignment in Primary Total Knee Arthroplasty: A 5-Year Survivorship Analysis.
PubMed 文献 · J Arthroplasty · 2025-03-04

本回顾性匹配队列研究纳入530例初次机器人辅助全膝关节置换术患者,比较胫骨假体有意置于≥3°内翻与中性机械对线(nMA)的5年生存率。结果显示两组5年全因生存率无显著差异(内翻组98% vs nMA组96%,P=0.12),内翻组无无菌性松动,翻修(5例 vs 14例,P=0.02)及因僵硬非翻修干预(3例 vs 14例,P=0.003)均少于nMA组。

要点

  • 胫骨假体置于≥3°内翻与中性机械对线的5年全因生存率无显著差异(98% vs 96%,P=0.12)。
  • 内翻组无无菌性松动病例,翻修5例 vs nMA组14例(P=0.02),内翻组更少。
  • 因僵硬行非翻修干预内翻组3例 vs nMA组14例(P=0.003),内翻组更少。

核心结论

  • 在5年中期随访中,采用功能性替代对线概念将胫骨假体有意置于≥3°内翻与中性机械对线的初次全膝关节置换术患者生存率相似。
  • 将胫骨假体置于体质性或解剖性内翻以恢复原生斜行关节线并保持良好平衡间隙,5年生存率达98%。

研究设计与样本

  • 回顾性匹配队列研究,纳入530例患者,其中265例接受初次机器人辅助全膝关节置换术且胫骨假体有意置于内翻,匹配265例采用手动器械将胫骨假体置于中性机械对线的对照组。
  • 两组均使用骨水泥型和非骨水泥型假体,组间患者性别和年龄无差异。
  • 胫骨内翻组和中性机械对线组分别有100%和87.5%的患者完成至少5年随访。

主要发现

  • 术后5年全因生存率在体质性胫骨内翻组为98%,在中性机械对线组为96%(P=0.12)。
  • 胫骨假体内翻组无无菌性松动病例。
  • 内翻组5例患者需翻修,中性机械对线组14例(P=0.02)。
  • 两组因僵硬行非翻修干预存在显著差异,内翻组3例 vs 中性机械对线组14例(P=0.003),利于内翻组。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Placing tibial components in varus alignment has been controversial due to concerns of loosening and subsequent revision. The purpose of this study was to compare 5-year survivorship of tibial components placed in 3° or greater of varus alignment versus neutral mechanical alignment (nMA). METHODS: This was a retrospective matched cohort study of 530 patients with 265 patients who underwent primary robotic-assisted total knee arthroplasty (TKA) with tibial components intentionally placed in varus matched to a control group of 265 patients who underwent TKA using manual instrumentation with tibial components placed in nMA. Both cementless and cemented implants were used in both groups. There was no difference between groups with respect to patient sex or age. There were 100 and 87.5% of patients who had a minimum 5-year follow-up in the tibial varus and nMA groups, respectively. Outcomes included survivorship, complications, revisions, and patient-reported outcome measures. RESULTS: All-cause survivorship at 5 years postoperatively was 98% in the group with constitutional tibial varus and 96% in the nMA group (P = 0.12). There were no cases of aseptic loosening in the group with tibial component varus. There were five patients who required revision in the varus group versus 14 in the nMA group (P = 0.02). There was a significant difference in nonrevision intervention for stiffness between the two groups in favor of the varus group (three versus 14, P = 0.003). CONCLUSIONS: Similar survivorship was demonstrated at a mid-term 5-year follow-up between patients undergoing primary TKA using a functional alternative alignment concept with tibial components intentionally placed in 3° or greater of varus compared to nMA. Tibial components placed in constitutional or anatomic varus, in an attempt to restore the native oblique joint line along with well-balanced gaps, demonstrated 98% survivorship at 5 years.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Bhimani RB, Whitaker JE, Mullick M, et al. Tibial Components Placed in Constitutional Varus Alignment in Primary Total Knee Arthroplasty: A 5-Year Survivorship Analysis. J Arthroplasty. 2025. PMID: 40049559. doi:10.1016/j.arth.2025.02.073

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。