文献速递关节外科

机器人辅助与传统全膝关节置换术中自动与手动股骨假体旋转规划的回顾性比较

Automated Versus Manual Femoral Component Rotation Planning in Robotic-Assisted and Conventional Total Knee Arthroplasty: A Retrospective Comparison.
PubMed 文献 · J Arthroplasty · 2025-03-09

这项回顾性多中心研究比较了传统全膝关节置换术(C-TKA,股骨假体旋转设为外旋3°)、机器人辅助全膝关节置换术(RA-TKA)中自动股骨旋转规划(A-RA-TKA)与术者手动设定股骨旋转(M-RA-TKA)的功能结局。A-RA-TKA组平均活动度改善显著高于M-RA-TKA组和C-TKA组,遗忘关节评分也显著更高;M-RA-TKA组股骨假体过度内旋(>4.5°)的例数显著更多,且与遗忘关节评分和KOOS-JR患者可接受症状状态达标率显著更低相关。

要点

  • A-RA-TKA组平均活动度改善22.7°,显著高于M-RA-TKA组的9.88°和C-TKA组的20.6°
  • A-RA-TKA组平均遗忘关节评分71.0,显著高于M-RA-TKA组的52.6和C-TKA组的60.5
  • M-RA-TKA组股骨假体内旋4.27°显著大于A-RA-TKA组的1.00°(P < 0.001)

核心结论

  • 与手动设定股骨旋转相比,自动股骨旋转规划有助于间室间间隙平衡并防止股骨假体过度旋转,后者可能与较差的功能结局相关。

研究设计与样本

  • 回顾性多中心研究,纳入随访至少一年的全膝关节置换术患者:传统方法股骨假体旋转设为外旋3°(C-TKA)108膝,机器人辅助自动股骨旋转规划(A-RA-TKA)111膝,机器人辅助术者手动设定股骨旋转(M-RA-TKA)152膝。

主要发现

  • A-RA-TKA组平均活动度改善22.7°,显著高于M-RA-TKA组的9.88°和C-TKA组的20.6°。
  • KOOS-JR改善未见显著差异,但A-RA-TKA组平均遗忘关节评分71.0,显著高于M-RA-TKA组的52.6和C-TKA组的60.5。
  • M-RA-TKA组股骨假体内旋4.27°显著大于A-RA-TKA组的1.00°(P < 0.001)。
  • M-RA-TKA组股骨假体高度内旋(>4.5°)的例数显著多于其他组,且与遗忘关节评分和KOOS-JR患者可接受症状状态达标率显著更低相关。

关键数值与推荐

  • 传统方法股骨假体旋转设为外旋3°(C-TKA组)。
  • 股骨假体高度内旋定义为>4.5°。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study was to determine if using automated femoral rotation planning in robotic-assisted total knee arthroplasty (RA-TKA) was associated with differences in functional outcomes compared to patients who underwent manually set femoral rotation in RA-TKA or conventional TKA (C-TKA). METHODS: This was a retrospective multicenter study of patients who underwent TKA utilizing conventional methods with femoral component rotation set to 3° externally (C-TKA) [n = 108 knees], RA-TKA with automated femoral rotation planning intrinsic to the system (A-RA-TKA) [n = 111], and RA-TKA with femoral rotation manually set by the surgeon (M-RA-TKA) [n = 152], at least one year before follow-up. Outcome measures included the range of motion, Knee Injury and Osteoarthritis Joint Replacement (KOOS-JR), and Forgotten Joint Score (FJS). Intraoperative intercompartmental laxity measures and the rotational position of the femoral component relative to the posterior condylar axis were recorded. RESULTS: In the A-RA-TKA group, the mean improvement in range of motion was significantly higher compared to both the M-RA-TKA and C-TKA groups (22.7 versus 9.88 and 20.6°, respectively). Significant differences in improvement in KOOS-JR were not seen, but patients in the A-RA-TKA group had significantly higher mean FJS than the M-RA-TKA and C-TKA groups (71.0 versus 52.6 and 60.5, respectively). Femoral component internal rotation was significantly greater in the M-RA-TKA group than in the A-RA-TKA group (4.27 versus 1.00°, P < 0.001). The M-RA-TKA group had a significantly higher number of highly internally rotated femoral components (> 4.5°) compared with the other groups, which was associated with significantly lower rates of achievement of FJS and KOOS-JR patient acceptable symptoms state. CONCLUSIONS: Compared to manually set femoral rotation, the use of automated femoral rotational planning facilitates intercompartmental gap balancing and prevents over-rotation of the femoral component, which may be associated with worse functional outcomes.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hohmann AL, Leipman JH, Dipane MV, et al. Automated Versus Manual Femoral Component Rotation Planning in Robotic-Assisted and Conventional Total Knee Arthroplasty: A Retrospective Comparison. J Arthroplasty. 2025. PMID: 40068724. doi:10.1016/j.arth.2025.03.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。