文献速递关节外科

急性假体周围关节感染滑膜标志物的诊断阈值:一刀切并不适用

Diagnostic Thresholds of Synovial Markers for Acute Periprosthetic Joint Infection: One Size Does Not Fit All.
PubMed 文献 · J Arthroplasty · 2025-02-27

这项多中心回顾性研究纳入214例初次全关节置换术后90天内行关节穿刺的患者,评估滑膜白细胞计数和中性粒细胞百分比在不同时间间隔诊断急性假体周围关节感染的价值。结果显示术后0至15天白细胞计数最佳阈值为21,003个/μL(AUC 0.937),15至45天降至5,111个/μL,45至90天降至2,503个/μL,而中性粒细胞百分比阈值未呈相同下降趋势。作者认为急性假体周围关节感染的诊断阈值可能需要根据关节穿刺时机进行特异性设定。

要点

  • 术后0至15天滑膜白细胞计数阈值21,003个/μL,AUC 0.937,敏感度88.0%,特异度100%。
  • 白细胞计数阈值随时间下降:15至45天为5,111个/μL,45至90天为2,503个/μL。
  • 0至15天白细胞计数AUC高于中性粒细胞百分比(P=0.002),其余时间间隔无差异。

核心结论

  • 作者认为,急性假体周围关节感染的诊断阈值可能需要根据初次全关节置换术后关节穿刺的时机进行特异性设定。

研究设计与样本

  • 多中心回顾性研究,在3家机构纳入初次全关节置换术后90天内行关节穿刺的患者,最终纳入214例。
  • 假体周围关节感染定义为关节穿刺后7天内因感染行翻修术且两次培养分离出同一微生物。
  • 无菌定义为关节穿刺后随访至多1年无再手术。
  • 采用受试者工作特征曲线评估术后0至15天、15至45天、45至90天白细胞计数和中性粒细胞百分比的诊断价值,采用约登指数确定各时间间隔的最佳截断值。

主要发现

  • 214例中,感染81例(37.9%),无菌133例(62.1%)。
  • 0至15天白细胞计数最佳截断值为21,003个/μL(AUC 0.937,敏感度88.0%,特异度100%),中性粒细胞百分比最佳截断值为92.0%(AUC 0.638,敏感度56.0%,特异度68.4%)。
  • 15至45天白细胞计数阈值为5,111个/μL,45至90天为2,503个/μL;中性粒细胞百分比阈值为15至45天80%、45至90天86%,未呈相同下降趋势。
  • 0至15天白细胞计数AUC高于中性粒细胞百分比(P=0.002);15至45天(P=0.438)和45至90天(P=0.826)两者AUC无差异。

关键数值与推荐

  • 0至15天:白细胞计数截断值21,003个/μL(AUC 0.937,敏感度88.0%,特异度100%);中性粒细胞百分比截断值92.0%(AUC 0.638,敏感度56.0%,特异度68.4%)。
  • 15至45天:白细胞计数截断值5,111个/μL;中性粒细胞百分比截断值80%。
  • 45至90天:白细胞计数截断值2,503个/μL;中性粒细胞百分比截断值86%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The diagnosis of periprosthetic joint infection (PJI), particularly during the early postoperative period, remains challenging. The purpose of this multicenter study was to assess the utility of synovial white blood cell (WBC) count and polymorphonuclear leukocyte percentage (PMN%) in the diagnosis of acute PJI at different time intervals after primary total joint arthroplasty (TJA). METHODS: This retrospective study identified 225 patients who underwent a joint aspiration within 90 days of their primary TJA at three institutions. A PJI was defined as revision TJA for infection within 7 days of joint aspiration with two positive cultures isolating the same organism. Patients were considered aseptic if they had no reoperation for up to 1 year after arthrocentesis. Receiver operator characteristic curves were used to assess the utility of WBC count and PMN% in the diagnosis of acute PJI at zero to 15, 15 to 45, and 45 to 90 days. Youden's index was used to identify the optimal cutoffs at each time interval. A pairwise comparison was performed to compare the area under the curve (AUC) of the two markers. There were 214 patients included. Of these, 81 (37.9%) were infected and 133 (62.1%) were aseptic. RESULTS: The optimal cutoff at zero to 15 days was 21,003 cells/μL for WBC count (AUC 0.937, sensitivity 88.0%, specificity 100%) and 92.0% for PMN% (AUC 0.638, sensitivity 56.0%, specificity 68.4%). Although the diagnostic threshold for WBC count decreased to 5,111 cells/μL at 15 to 45 days and to 2,503 cells/μL at 45 to 90 days, the cutoffs for PMN% did not downtrend in the same fashion (80% at 15 to 45 days; 86% at 45 to 90 days). Using pairwise comparison, the AUC for WBC count was higher than that of PMN% at 0 to 15 days (P = 0.002); however, there was no difference in AUCs at either 15 to 45 days (P = 0.438) or 45 to 90 days (P = 0.826). CONCLUSIONS: Based on our findings, it appears that there may be a role for diagnostic thresholds for the identification of acute PJI that are specific to the timing of joint aspiration after primary TJA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tarabichi S, Verhey JT, Lizcano JD, et al. Diagnostic Thresholds of Synovial Markers for Acute Periprosthetic Joint Infection: One Size Does Not Fit All. J Arthroplasty. 2025. PMID: 40023460. doi:10.1016/j.arth.2025.02.064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。