文献速递关节外科

全髋关节置换术中关节中心重建的精确性及其对术后股骨轴向旋转的影响

Accuracy of Joint Center Reconstruction in Total Hip Arthroplasty and Its Effect on Postoperative Femoral Axial Rotation.
PubMed 文献 · J Arthroplasty · 2025-03-28

该研究纳入938例分期双侧全髋关节置换术后患者,通过三维术前规划与术前术后CT自动配准比较髋关节旋转中心变化。结果显示髋臼旋转中心平均内移4.6 mm、股骨旋转中心平均内移5.1 mm,整体前后移位平均减少0.9 mm,整体前后移位变化与股骨内旋变化中度相关(r=0.5),整体前后移位每增加1 mm股骨内旋平均增加0.6°(P<0.0001),24%病例整体前后移位增加>5 mm时股骨内旋平均增加10°。

要点

  • 全髋关节置换术后髋臼旋转中心平均内移约5 mm,股骨偏心距代偿性增加。
  • 整体前后移位平均减少1.0 mm,但患者个体间差异显著。
  • 整体前后移位变化与股骨内旋变化中度相关(r=0.5),每毫米增加对应内旋平均增加0.6°。

核心结论

  • 全髋关节置换术后髋臼旋转中心平均内移约5 mm,股骨偏心距代偿性增加,从而增加肌肉力臂和骨-柄界面扭矩。
  • 整体前后移位平均减少1.0 mm,但患者个体间变异显著;当这些变化超过5 mm时,可显著改变下肢轴向旋转对线。

研究设计与样本

  • 研究纳入938例分期双侧全髋关节置换术后患者,每例均接受三维术前规划分析。
  • 通过术前与术后计算机断层扫描自动配准,精确比较术前与术后髋关节旋转中心。
  • 整体前后移位变化定义为股骨旋转中心前移与骨盆旋转中心后移的联合差值;采用线性回归评估整体前后移位变化与股骨内旋的关系。

主要发现

  • 髋臼旋转中心相对于原生旋转中心平均内移4.6 mm,股骨旋转中心平均内移5.1 mm,导致整体内外侧偏移平均增加0.5 mm。
  • 髋臼与股骨旋转中心分别平均向近端移位0.4 mm和2.8 mm,导致髋关节长度平均增加2.4 mm。
  • 髋臼与股骨旋转中心分别平均向前移位-1.7 mm和-0.8 mm,导致整体前后移位平均减少0.9 mm。
  • 整体前后移位变化与股骨内旋变化中度相关(r=0.5),回归斜率显示整体前后移位每增加1 mm,股骨内旋平均增加0.6°(P<0.0001)。
  • 24%的病例整体前后移位增加>5 mm,导致股骨内旋平均增加10°。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Displacement of the native hip center of rotation (COR) following total hip arthroplasty (THA) alters biomechanical load distribution and may adversely affect outcomes. This analysis quantified alterations in the COR following THA and their relationship with postoperative axial femoral rotation. METHODS: There were 938 patients evaluated following staged bilateral THA. Each underwent a three-dimensional preoperative planning analysis. Automated registration between preoperative and postoperative computed tomography scans enabled the hip COR to be accurately compared preoperatively versus postoperatively. Changes in global anterior-posterior (AP) shift were defined by the combined difference between the anteriorization of the femoral COR and the posteriorization of the pelvic COR. Changes in global AP shift versus femoral internal rotation were assessed using linear regression. RESULTS: The mean acetabular COR was medialized by 4.6 mm and femoral COR by 5.1 mm relative to the native COR, resulting in a global medial-lateral offset increase of 0.5 mm. Similarly, the achieved acetabular and femoral CORs were shifted proximally by 0.4 and 2.8 mm, respectively, resulting in an average increase in hip length of 2.4 mm. Acetabular and femoral CORs were shifted anteriorly by -1.7 and -0.8 mm, respectively, resulting in a global AP shift decrease of 0.9 mm. Change in global AP shift was moderately correlated with change in femoral internal rotation (r = 0.5), with a regression slope indicating an average increase in femoral internal rotation of 0.6° per millimeter increase in global AP shift (P < 0.0001). Global AP shift increased by > 5 mm in 24% of cases, resulting in an average increase in femoral internal rotation of 10°. CONCLUSIONS: Acetabular COR is medialized by approximately five mm following THA with a compensatory increase in femoral offset, increasing muscle moment arms and increasing torque at the bone-stem interface. On average, global AP shift decreased by 1.0 mm, though there was significant patient-specific variability. When these changes exceed five mm, they can significantly alter axial rotational limb alignment.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Dennis DA, Plaskos C, Pierrepont JW, et al. Accuracy of Joint Center Reconstruction in Total Hip Arthroplasty and Its Effect on Postoperative Femoral Axial Rotation. J Arthroplasty. 2025. PMID: 40158750. doi:10.1016/j.arth.2025.03.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。