仅用髓锉技术的短柄非骨水泥无领适配填充型全髋关节置换术:平均5年随访
本研究回顾了505例采用仅髓锉技术植入短柄非骨水泥无领适配填充型股骨柄的全髋关节置换术,随访2至9年(平均5.6年)。末次随访Harris髋关节评分平均90分、疼痛评分平均42分,82%髋关节无疼痛,无股骨无菌性松动;但14%股骨柄置入内翻超过5度,术中股骨骨折13髋(2.5%),2例股骨柄翻修。作者认为该技术的理论优势可能被内翻置入和股骨近端骨折倾向所抵消,但内翻股骨柄在平均5年随访时仍稳固骨长入且影像学稳定。
要点
- 505例仅髓锉技术植入短柄非骨水泥无领适配填充型股骨柄,平均随访5.6年
- 末次随访Harris髋关节评分平均90分、疼痛评分平均42分,82%髋关节无疼痛
- 14%股骨柄内翻超过5度,术中股骨骨折13髋(2.5%),2例翻修
核心结论
- 作者认为,使用该无领适配填充型股骨柄时,仅髓锉技术的理论优势可能被内翻置入和股骨近端骨折的倾向所抵消。
- 作者指出,本系列中内翻置入的股骨柄在平均5年随访时仍稳固骨长入且影像学稳定。
研究设计与样本
- 回顾性连续系列,共505例非骨水泥全髋关节置换术,随访2至9年。
- 患者平均年龄62岁(范围32至91岁),54%为男性;Dorr分型A型31%、B型64%、C型5%。
- 所有患者随访至少2年,平均随访5.6年(范围2至9年)。
主要发现
- 末次随访平均Harris髋关节评分为90分,平均疼痛评分为42分。
- 82%的髋关节评为无疼痛;仅1例患者报告活动相关大腿疼痛。
- 无股骨无菌性松动病例。
- 术中14%的股骨柄置入内翻超过5度;13髋(2.5%)发生术中股骨骨折。
- 2例股骨柄翻修(1例感染,1例晚期股骨骨折)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Short femoral stem use in total hip arthroplasty can preserve bone stock and may diminish thigh pain. Tapered-wedge short stems are appealing, because reaming is not typically required as it is with classic "fit-and-fill" designed stems. This study aimed to evaluate the minimum 2-year clinical, radiographic, and clinical results of a short, uncemented, and collarless, fit-and-fill stem implanted using a broach-only technique. METHODS: The clinical and radiographic results of a consecutive series of 505 cementless THAs were reviewed from 2 to 9 years postoperatively. The average age was 62 years (range, 32 to 91), and 54% of the patients were men. Dorr's class was 31% A, 64% B, and 5% C. All patients were followed for a minimum of 2 years. The average follow-up was 5.6 years (range, two to nine). RESULTS: At the final follow-up, the average Harris hip and pain scores were 90 and 42, respectively. There were 82% of hips rated as pain-free. A single patient reported activity-related thigh pain. There were no cases of femoral aseptic loosening. At operation, 14% of stems were placed in more than five degrees of varus. An intraoperative femur fracture occurred in 13 hips (2.5%). There were two stems revised (one infection and one late femur fracture). CONCLUSIONS: The theoretical advantages of using this collarless fit-and-fill stem may be offset by the tendency for varus placement and proximal femur fracture when using a broach-only technique. Nevertheless, the varus stems in this series remain well-ingrown and radiographically stable at an average 5-year follow-up.
引用
- Meding JB, Meding LK, Deckard ER, et al. Broach Only Total Hip Arthroplasty Using a Short, Uncemented, and Collarless, Fit-and-Fill Stem: Average 5-Year Follow-Up. J Arthroplasty. 2025. PMID: 40107583. doi:10.1016/j.arth.2025.03.032
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。