全膝关节置换术中股骨屈曲角分布与活动度的分析
这项多中心前瞻性病例系列纳入976例接受计算机断层扫描机器人系统辅助全膝关节置换术的患者,按平均股骨植入物屈曲角分为高屈曲角组(448例,平均5.93°±1.06)和低屈曲角组(528例,平均2.45°±1.28)。股骨屈曲角呈正态分布,高屈曲角与骨水泥型植入物、较小植入物及女性相关。各随访时间点两组屈曲活动度无差异,仅末次随访伸直活动度存在非临床显著差异(低屈曲角组0° vs 高屈曲角组0.1°,P=0.050)。
要点
- 股骨植入物屈曲角呈正态分布,平均4.05°±2.10(范围0至9°)。
- 高屈曲角组女性比例更高(62.5% vs 53.0%,P=0.006),骨水泥型植入物更多(20.4% vs 14.4%,P=0.020),植入物更小(P<0.001)。
- 各随访时间点两组屈曲活动度无差异,仅末次随访伸直活动度有非临床显著差异(低屈曲角组0° vs 高屈曲角组0.1°,P=0.050)。
核心结论
- 股骨植入物屈曲角呈正态分布,较高角度与骨水泥型植入物、较小植入物及女性相关。
- 高屈曲角组与低屈曲角组在所有随访时间点的活动度无临床意义差异。
研究设计与样本
- 多中心前瞻性病例系列,纳入976例接受计算机断层扫描机器人系统辅助全膝关节置换术的患者,年龄66岁(范围38至90),体重指数32.6(范围14.3至50.2),女性占56.6%。
主要发现
- 平均股骨植入物屈曲角为4.05°±2.10(范围0至9°);低屈曲角组(n=528)平均2.45°±1.28,高屈曲角组(n=448)平均5.93°±1.06。
- 两组患者身高、体重、体重指数无差异;术前膝关节对线及活动度无差异。
- 高屈曲角组女性更多(62.5% vs 53.0%,P=0.006),骨水泥型植入物更多(20.4% vs 14.4%,P=0.020),植入物更小(P<0.001)。
- 末次随访伸直活动度低屈曲角组0° vs 高屈曲角组0.1°(P=0.050),为非临床显著差异;各随访时间点屈曲活动度无差异。
关键数值与推荐
- 按平均股骨植入物屈曲角分为高屈曲角组和低屈曲角组。
- 活动度在术前、术后早期、术后中期和术后晚期四个时间点评估。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Optimal coronal and rotational alignment in total knee arthroplasty is essential for satisfactory outcomes. There has been limited focus on sagittal alignment in assessing outcomes. This study investigated the impact of femoral implant flexion (FF) angle on knee kinematics and postoperative outcomes. METHODS: In this multicenter, prospective case series, we analyzed demographics, preoperative and postoperative range of motion (ROM), and implant alignment in patients undergoing total knee arthroplasty with a computed tomography-based robotic system. The study included 976 patients (age 66 years [range, 38 to 90]; body mass index 32.6 [range, 14.3 to 50.2]; 56.6% women). The ROM was assessed at four intervals: preoperative, early postoperative, middle postoperative, and late postoperative. Patients were divided into "high FF" and "low FF" groups based on mean FF. Comparisons were made using t-tests and Pearson's Chi-square tests. RESULTS: The average FF was 4.05° ± 2.10 (range, 0 to 9). The low FF group (n = 528) had a mean FF of 2.45° ± 1.28. The high FF group (n = 448) had a mean of 5.93° ± 1.06. No differences were found in patient height, weight, or body mass index. No differences were noted in preoperative knee alignment or ROM between groups. The high FF patients were more frequently women (62.5 versus 53.0%; P = 0.006), had more cemented implants (20.4 versus 14.4%; P = 0.020), and had smaller implants (P < 0.001). At the latest follow-up, a nonclinically significant difference in extension ROM was noted (low FF 0°, high FF 0.1°; P = 0.050). No differences in flexion ROM were observed at any visit. CONCLUSIONS: The FF angles showed a normal distribution, with higher angles associated with cemented implants, smaller implants, and women. No clinically meaningful differences in ROM were found between the high and the low FF groups across all visits.