新型三维打印非骨水泥全膝关节置换术的10年随访
单机构注册研究对113例三维打印非骨水泥全膝关节置换术进行10年随访,总体生存率96.5%,无菌性松动终点生存率98.2%,3D打印胫骨部件生存率99.1%;共4例翻修(3.5%),均发生在术后2年内;KOOS-JR、VR-12躯体与心理评分均较术前显著改善(P=0.0001)。
要点
- 10年总体生存率96.5%,无菌性松动终点98.2%,3D打印胫骨部件99.1%。
- 4例翻修(3.5%),其中感染2例(1.7%)、松动2例(1.7%),均在术后2年内。
- 术后2年后未再发现新的松动,KOOS-JR与VR-12评分较术前显著改善(P=0.0001)。
核心结论
- 该三维打印非骨水泥全膝关节系统在10年随访中显示出优异的生存率,其设计和实现非骨水泥固定的能力为良好的长期耐久性带来希望。
研究设计与样本
- 单机构注册研究,回顾性分析前瞻性收集的数据,共纳入113例非骨水泥全膝关节置换术,随访10年。
主要发现
- 10年总体生存率为96.5%,以无菌性松动为终点的生存率为98.2%,三维打印胫骨部件生存率为99.1%。
- 共实施4例翻修(总体翻修率3.5%),均在术后2年内完成:感染2例(1.7%)、松动2例(1.7%)。
- 随访2年后未发现新的松动。
- 10年随访时,KOOS-JR评分从术前38.2改善至术后72.8(P=0.0001)。
- VR-12躯体健康评分从术前29.8改善至术后40.6(P=0.0001),心理健康评分从术前37.02改善至术后54.3(P=0.0001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cementless total knee arthroplasty (TKA) offers the potential for durable fixation through biological integration compared to cemented TKA, where fixation is achieved through mechanical interdigitation of the cement. To our knowledge, no 10-year results are available for newer cementless TKA designs that have incorporated additive manufacturing (three-dimensional [3D] printing). The purpose of this study was to present 10-year survivorship and clinical/radiographic outcomes of a newer cementless TKA design. METHODS: This is a single institution registry review of prospectively obtained data from a total of 113 cementless TKAs at a 10-year follow-up. Outcomes were determined by comparing pre-and post-operative Knee Injury and Osteoarthritis Outcome Scores for Joint Replacement scores and pre- and post-operative 12-item Veterans RAND/Short Form Health Survey. Aseptic loosening as well as revision for any reason were the end points used to determine survivorship at 10 years. RESULTS: The overall survivorship was 96.5% at 10 years, and survivorship for aseptic loosening as the end point was 98.2%, with a 99.1% survivorship of the 3D printed tibial component. There were four revisions performed (all within 2 years postoperatively) for an overall revision rate of 3.5%: two infections (1.7%) and two loosenings (1.7%). No new loosening was identified after 2 years of follow-up. At long-term 10-year follow-up, the mean Knee Injury and Osteoarthritis Outcome Scores for Joint Replacement score improved from 38.2 preoperatively to 72.8 postoperatively (P = 0.0001), the mean 12-item Veterans RAND/Short Form Health Survey scores improved from physical health-29.8 preoperatively to 40.6 postoperatively (P = 0.0001), and the mental health scores improved from 37.02 preoperatively to 54.3 postoperatively (P = 0.0001). CONCLUSIONS: This 3D printed cementless total knee system shows exceptional survivorship at a 10-year follow-up. The design of this implant and the ability to obtain cementless fixation offer promise for excellent long-term durability.
引用
- Zappley NR, Restrepo S, Fraval A, et al. 10-Year Follow-Up for a New Three-Dimensional Printed Cementless Total Knee Arthroplasty. J Arthroplasty. 2025. PMID: 40121147. doi:10.1016/j.arth.2025.02.043
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。