文献速递创伤骨科关节外科

股骨颈系统与3枚空心螺钉治疗60岁及以上患者股骨颈骨折的比较:一项多中心登记研究

Femoral Neck System Compared with 3 Cannulated Screws in the Treatment of Femoral Neck Fracture in Patients Aged 60 and Older: A Multicenter Registry-Based Study.
PubMed 文献 · J Bone Joint Surg Am · 2025-03-28

该多中心登记研究比较股骨颈系统(FNS)与3枚空心螺钉固定60岁及以上股骨颈骨折患者的全因翻修风险。共纳入352例FNS和1686例空心螺钉修复,2年翻修率分别为4.0%和4.8%,调整后全因翻修风险无差异(HR=0.92,95%CI=0.50~1.71,p=0.79)。2年死亡率分别为23.6%和25.2%。

要点

  • 60岁及以上股骨颈骨折患者中,FNS与3枚空心螺钉的2年全因翻修率分别为4.0%和4.8%。
  • 调整混杂后全因翻修风险无差异(HR=0.92,95%CI=0.50~1.71,p=0.79)。
  • 仅使用两种器械的术者亚组分析翻修率亦无差异(HR=0.91,95%CI=0.39~2.17,p=0.84)。

核心结论

  • 在60岁及以上股骨颈骨折患者中,FNS与多枚空心螺钉的全因翻修率和死亡率相似。

研究设计与样本

  • 多中心登记研究,基于Kaiser Permanente髋部骨折登记系统识别2017年至2022年接受FNS或3枚空心螺钉固定的60岁及以上股骨颈骨折患者。
  • 排除标准为多发伤、病理性骨折、开放性骨折、同一住院期间其他部位额外手术及患髋既往手术史。
  • 共纳入352例FNS修复和1686例空心螺钉修复;主要结局为全因翻修手术,次要结局为死亡率、急诊就诊和再入院。
  • 采用多变量Cox比例风险或logistic回归,控制多种潜在混杂因素。
  • 证据等级为治疗性III级。

主要发现

  • 2年全因翻修总体发生率:FNS组4.0%,空心螺钉组4.8%。
  • 2年死亡率:FNS组23.6%,空心螺钉组25.2%。
  • 调整分析中,FNS与空心螺钉的全因翻修风险无差异(HR=0.92,95%CI=0.50~1.71,p=0.79)。
  • 在同时使用两种器械的术者所行手术的亚组分析中,翻修率亦无差异(HR=0.91,95%CI=0.39~2.17,p=0.84)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: While the Femoral Neck System (FNS) is increasingly utilized for the fixation of femoral neck fractures in elderly patients, studies comparing the device to the historical standard (that is, multiple cannulated screws) are lacking. The purpose of this study was to determine the risk of all-cause revision following fixation with the FNS device compared with multiple cannulated screws in patients ≥60 years of age with a femoral neck fracture. METHODS: Patients ≥60 years of age who underwent fixation of a femoral neck fracture with the FNS or 3 cannulated screws (2017 to 2022) were identified using the Kaiser Permanente Hip Fracture Registry. Exclusion criteria were polytrauma, pathologic fracture, open fracture, additional surgeries at other sites during the same hospital stay, and prior procedures on the affected hip. The primary outcome measure was all-cause revision surgery, and the secondary outcome measures were mortality, emergency department visits, and readmissions. Multivariable Cox proportional hazards or logistic regression was performed, controlling for a wide range of potential confounders. RESULTS: A total of 352 FNS and 1,686 cannulated-screw repairs were included. The overall incidence of revision at 2 years was 4.0% and 4.8% for the FNS and cannulated-screw constructs, respectively. Mortality at 2 years was 23.6% and 25.2%, respectively. In the adjusted analysis, no difference in all-cause revision risk was observed when comparing the FNS to cannulated screws (hazard ratio [HR] = 0.92, 95% confidence interval [CI] = 0.50 to 1.71; p = 0.79). A subgroup analysis of procedures performed by surgeons who used both devices also did not demonstrate a difference in revision rates (HR = 0.91; 95% CI = 0.39 to 2.17; p = 0.84). CONCLUSIONS: In this study of patients ≥60 years of age with a femoral neck fracture, the rates of all-cause revision and mortality were found to be similar between the FNS and multiple cannulated screws. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Mallon ZO, Prentice HA, Schlauch AM, et al. Femoral Neck System Compared with 3 Cannulated Screws in the Treatment of Femoral Neck Fracture in Patients Aged 60 and Older: A Multicenter Registry-Based Study. J Bone Joint Surg Am. 2025. PMID: 40153479. doi:10.2106/JBJS.24.00781

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。