肩胛盂骨缺损模型中恢复凹陷度对盂肱关节稳定性的影响:远端胫骨同种异体骨移植重建与经典Latarjet术的比较
在9具人尸体标本上建立肩胛盂骨缺损模型,比较远端胫骨同种异体骨移植(DTA)与经典Latarjet术对肩胛盂凹陷度和前方稳定性的恢复效果。DTA产生的BSSR高于Latarjet(0.45 vs 0.35,P<.001);在无联合腱加载时DTA最大前移小于Latarjet(5.1 mm vs 10.3 mm,P=.045),而在联合腱加载时两者前移无差异(5.1 mm vs 4.7 mm,P>.999)。
要点
- DTA重建的肩胛盂凹陷度(BSSR 0.45)优于经典Latarjet(0.35),P<.001。
- 无联合腱加载时,DTA最大前移5.1 mm小于Latarjet的10.3 mm,P=.045。
- 联合腱加载时,DTA与Latarjet前移无差异(5.1 mm vs 4.7 mm,P>.999)。
核心结论
- DTA产生更凹陷的重建,且与无联合腱加载的经典Latarjet相比前移减少。
- DTA与联合腱加载的经典Latarjet在前移减少方面等效。
研究设计与样本
- 受控实验室研究,使用9具人尸体肩关节标本(平均年龄62.2岁,范围52-69岁)。
- 测试前CT评估原生肩胛盂凹陷度(盂深度和骨性肩关节稳定比BSSR)。
- 创建肩胛盂骨缺损,使DTA和Latarjet移植物均恢复100%原生肩胛盂宽度。
- 加载肩袖肌腱,使用KUKA机器人于肩关节外展90°、中立外旋位施加受控前方力进行前方稳定性测试。
- 运动捕捉系统记录肱骨头位移,测试后CT测量DTA和Latarjet重建的BSSR。
主要发现
- DTA产生的BSSR为0.45,Latarjet为0.35,DTA大于Latarjet(P<.001)。
- 联合腱加载(吊索效应)时,DTA与Latarjet最大前移无差异(5.1 mm vs 4.7 mm,P>.999)。
- 无联合腱加载时,DTA最大前移小于Latarjet(5.1 mm vs 10.3 mm,P=.045)。
关键数值与推荐
- DTA重建BSSR为0.45,Latarjet重建BSSR为0.35,P<.001。
- 联合腱加载时最大前移DTA 5.1 mm vs Latarjet 4.7 mm,P>.999。
- 无联合腱加载时最大前移DTA 5.1 mm vs Latarjet 10.3 mm,P=.045。
临床怎么用
- 作者认为,DTA重建因同时恢复肩胛盂宽度和凹陷度,是经典Latarjet的生物力学等效替代方案。
- 作者建议,在处理伴骨缺损的盂肱关节不稳定时应考虑凹陷度的作用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Distal tibial allograft (DTA) reconstruction for glenoid bone loss (GBL) has gained popularity. While recent studies have demonstrated that glenoid concavity is an important factor in native glenohumeral stability, there remains a paucity of data regarding concavity restoration during reconstructive procedures for GBL and its biomechanical effect. PURPOSE: To compare the restoration of anterior glenohumeral stability and glenoid concavity after DTA and classic Latarjet procedures. STUDY DESIGN: Controlled laboratory study. METHODS: Nine human cadaveric specimens (mean age, 62.2 years; range, 52-69 years) underwent pretesting computed tomography (CT) to assess native glenoid concavity as determined by the glenoid depth and bony shoulder stability ratio (BSSR). GBL was created so the DTA and Latarjet graft could restore 100% of the native glenoid width. The rotator cuff tendons were loaded, and anterior stability testing was performed using a KUKA robot to apply a controlled anterior force with the shoulder in 90° of abduction and neutral external rotation. A motion capture system recorded humeral head translation. The following conditions were tested: intact, soft tissue Bankart lesion; bone loss model with DTA reconstruction; classic Latarjet procedure without conjoint tendon loaded; and classic Latarjet procedure with conjoint tendon loaded (sling effect). All specimens underwent posttesting CT to measure the BSSR of the DTA and Latarjet reconstructions. A repeated-measures analysis of variance was performed to compare the BSSR and anterior translations between the DTA and Latarjet reconstructions. RESULTS: DTA produced greater concavity than the Latarjet procedure (BSSR: 0.45 vs 0.35; P < .001). There was no difference in anterior translation between the DTA and Latarjet procedures with the sling effect (5.1 mm vs 4.7 mm; P > .999). However, maximum anterior translation was decreased after the DTA procedure when compared with the Latarjet technique without the sling effect (5.1 mm vs 10.3 mm; P = .045). CONCLUSION: DTA produces a more concave reconstruction and decreased anterior translation compared with the flatter reconstruction produced by the classic Latarjet procedure without the sling effect. DTA and the classic Latarjet procedure with conjoint tendon loading, however, yielded equivalent reductions in anterior translation. CLINICAL RELEVANCE: Distal tibial allograft reconstruction is a biomechanically equivalent alternative to the classic Latarjet due to the restoration of glenoid concavity in addition to glenoid width. Surgeons should consider the role of concavity when addressing glenohumeral instability with bone loss.
引用
- Fury MS, Cirino CM, Jahandar A, et al. The Effect of Concavity Restoration on Glenohumeral Stability in a Glenoid Bone Loss Model: Comparing Distal Tibial Allograft Reconstruction to Classic Latarjet. Am J Sports Med. 2025. PMID: 39920605. doi:10.1177/03635465251318337
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。