文献速递运动医学关节外科

塞萨利移植物指数:一种基于人工智能的评估前交叉韧带重建术后移植物完整性的指数

Thessaly Graft Index: An Artificial Intelligence-Based Index for the Assessment of Graft Integrity in ACL-Reconstructed Knees.
PubMed 文献 · J Bone Joint Surg Am · 2025-02-07

该队列研究纳入24例孤立性前交叉韧带损伤并接受腘绳肌腱自体移植治疗的患者,随访1年,基于YOLOv5 Nano版本构建人工智能模型计算塞萨利移植物指数(TGI),术前和术后TGI平均分分别为64.21±8.96和82.37±3.53,术后将移植物归类为健康的TGI最低阈值为79.21%,22例移植物为完整、2例为再断裂,TGI与KT-1000及患者报告结局评分呈中度至良好相关。

要点

  • 术前和术后TGI平均分分别为64.21±8.96和82.37±3.53,平均增加15%。
  • 术后MRI将移植物归类为健康的TGI最低阈值为79.21%。
  • 放射科医师评估与TGI评分完全一致,TGI与TAS、IKDC、Lysholm、KOOS总分和KT-1000的相关性为中度至良好。

核心结论

  • TGI是一种能够准确识别前交叉韧带移植物断裂的人工智能工具。
  • TGI与术后KT-1000值和患者报告结局评分相关。

研究设计与样本

  • 队列研究纳入24例孤立性前交叉韧带损伤并接受腘绳肌腱自体移植治疗的患者,随访1年。
  • 术前和术后1年行MRI检查,临床和功能评估采用KT-1000及以下患者报告结局指标:KOOS、IKDC、Lysholm评分和TAS。
  • 基于YOLOv5 Nano版本设计人工智能模型,在KneeMRI数据集的健康膝和损伤膝上训练,用于在矢状面计算准确检测健康前交叉韧带的概率(百分比量表),并评估前交叉韧带移植物完整性,最高分100分。
  • 结果与独立放射科医师的MRI评估进行比较,并与患者报告结局指标和KT-1000松弛度进行相关性分析。

主要发现

  • 术前和术后TGI平均分分别为64.21±8.96和82.37±3.53,术前与术后图像之间TGI评分平均增加15%。
  • 术后MRI将移植物归类为健康的TGI最低阈值为79.21%。
  • 22例移植物被判定为完整,2例为再断裂,术后TGI评分分别为71%和42%。
  • 放射科医师评估与TGI评分完全一致。
  • TGI与TAS(0.668)、IKDC(0.516)、Lysholm(0.521)、KOOS总分(0.594)和KT-1000(0.561)的相关性为中度至良好。

关键数值与推荐

  • 术后MRI将移植物归类为健康的TGI最低阈值为79.21%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 证据等级为诊断性研究Level IV。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Magnetic resonance imaging (MRI) has proven to be a valuable noninvasive tool to evaluate graft integrity after anterior cruciate ligament (ACL) reconstruction. However, MRI protocols and interpretation methodologies are quite diverse, preventing comparisons of signal intensity across subsequent scans and independent investigations. The purpose of this study was to create an artificial intelligence (AI)-based index (Thessaly Graft Index [TGI]) for the evaluation of graft integrity following ACL reconstruction. METHODS: The cohort study included 24 patients with an isolated ACL injury that had been treated with a hamstring tendon autograft and followed for 1 year. MRI was performed preoperatively and 1 year postoperatively. The clinical and functional evaluations were performed with use of the KT-1000 and with the following patient-reported outcome measures (PROMs): the Knee Injury and Osteoarthritis Outcome Score (KOOS), the International Knee Documentation Committee Subjective Knee Function form (IKDC), the Lysholm score, and the Tegner Activity Scale (TAS). An AI model, based on the YOLOv5 Nano version, was designed to compute the probability of accurately detecting, in the sagittal plane, a healthy ACL (on a percentage scale) and was trained on healthy and injured knees from the KneeMRI dataset. The model was used to assess the integrity of ACL grafts, with a maximum score of 100. The results were compared with the MRI assessment from an independent radiologist and were correlated with PROMs and KT-1000 laxity. RESULTS: The mean preoperative and postoperative TGI scores were 64.21 ± 8.96 and 82.37 ± 3.53, respectively. A mean increase of 15% in the TGI scores was observed between preoperative and postoperative images. The minimum threshold for TGI to categorize a graft as healthy on the postoperative MRI was 79.21%. Twenty-two grafts were characterized as intact and 2 as reruptured, with postoperative TGI scores of 71% and 42%. The radiologist's assessment was in total agreement with the TGI scores. The correlation of the TGI ranged from moderate to good with the TAS (0.668), IKDC (0.516), Lysholm (0.521), KOOS total (0.594), and KT-1000 (0.561). CONCLUSIONS: The TGI is an AI tool that is able to accurately recognize an ACL graft rupture. Moreover, the TGI correlated with the KT-1000 postoperative values and PROM scores. LEVEL OF EVIDENCE: Diagnostic Level IV . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Chalatsis G, Siouras A, Mitrousias V, et al. Thessaly Graft Index: An Artificial Intelligence-Based Index for the Assessment of Graft Integrity in ACL-Reconstructed Knees. J Bone Joint Surg Am. 2025. PMID: 39919170. doi:10.2106/JBJS.24.00427

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。