文献速递关节外科小儿骨科

髋臼假体位置显著影响Crowe III/IV型发育性髋关节发育不良患者全髋关节置换术后骨盆矢状面倾斜的再平衡

Acetabular component position significantly influences the rebalancing of pelvic sagittal inclination following total hip arthroplasty in patients with Crowe type III/IV developmental dysplasia of the hip.
PubMed 文献 · Bone Joint J · 2025-02-01

本研究纳入61例Crowe III/IV型发育性髋关节发育不良行全髋关节置换术的患者,使用SPINEPARA软件测量骨盆矢状面参数。术后一年骨盆后倾,骨盆入射角与骨盆倾斜的线性回归方程为PT=0.45×PI-10.5°,由此推算的骨盆矢状面倾斜计算值与实测值在55/61例(90.16%)中绝对差小于5°。结论认为髋臼假体位置创建的新骨盆入射角显著影响术后腰椎-骨盆序列再平衡时的骨盆矢状面倾斜。

要点

  • 全髋关节置换术后一年骨盆倾斜从术前7.0°增至8.4°,骨盆矢状面倾斜从-8.0°变为-4.5°,骨盆后倾。
  • 腰椎-骨盆序列再平衡时,骨盆入射角与骨盆倾斜的线性回归方程为PT=0.45×PI-10.5°。
  • 骨盆矢状面倾斜计算值与实测值绝对差小于5°者占55/61例(90.16%)。

核心结论

  • 在Crowe III/IV型发育性髋关节发育不良患者中,全髋关节置换术后腰椎-骨盆序列变化并再平衡时,髋臼假体位置所创建的新骨盆入射角显著影响骨盆矢状面倾斜。

研究设计与样本

  • 使用SPINEPARA软件测量61例Crowe III/IV型发育性髋关节发育不良患者的骨盆矢状面参数(骨盆入射角、骨盆倾斜、骨盆矢状面倾斜),建立全髋关节置换术后一年骨盆入射角与骨盆倾斜的回归方程,并用Bland-Altman法评价计算骨盆矢状面倾斜与实测骨盆矢状面倾斜的一致性。

主要发现

  • 平均骨盆倾斜从术前7.0°(SD 6.5°)变为术后一年8.4°(SD 5.5°),平均骨盆矢状面倾斜从术前-8.0°(SD 6.7°)变为术后一年-4.5°(SD 5.9°),提示全髋关节置换术后骨盆后倾。
  • 腰椎-骨盆序列再平衡时,骨盆入射角与骨盆倾斜的线性回归方程为PT=0.45×PI-10.5°,骨盆矢状面倾斜可表示为PSI=0.45×PI-10.5°-∠γ。
  • 计算骨盆矢状面倾斜与实测骨盆矢状面倾斜的绝对差在55/61例(90.16%)中小于5°。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Sagittal lumbar pelvic alignment alters with posterior pelvic tilt (PT) following total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH). The individual value of pelvic sagittal inclination (PSI) following rebalancing of lumbar-pelvic alignment is unknown. In different populations, PT regresses in a linear relationship with pelvic incidence (PI). PSI and PT have a direct relationship to each other via a fixed individual angle ∠γ. This study aimed to investigate whether the new PI created by acetabular component positioning during THA also has a linear regression relationship with PT/PSI when lumbar-pelvic alignment rebalances postoperatively in patients with Crowe type III/IV DDH. METHODS: Using SPINEPARA software, we measured the pelvic sagittal parameters including PI, PT, and PSI in 61 patients with Crowe III/IV DDH. Both PSI and PT represent the pelvic tilt state, and the difference between their values is ∠γ (PT = PSI + ∠γ). The regression equation between PI and PT at one year after THA was established. By substituting ∠γ, the relationship between PI and PSI was also established. The Bland-Altman method was used to evaluate the consistency between the PSI calculated by the linear regression equation (ePSI) and the actual PSI (aPSI) measured one year postoperatively. RESULTS: The mean PT and PSI changed from preoperative values of 7.0° (SD 6.5°) and -8.0° (SD 6.7°), respectively, to 8.4° (SD 5.5°) and -4.5° (SD 5.9°) at one year postoperatively. This change shows that the pelvis tilted posteriorly following THA. In addition, when lumbar-pelvic alignment rebalanced, the linear regression equation between PI and PT was PT = 0.45 × PI - 10.5°, and PSI could be expressed as PSI = 0.45 × PI - 10.5° - ∠γ. The absolute difference between ePSI and aPSI was less than 5° in 55 of 61 patients (90.16%). CONCLUSION: The new PI created by the positioning of the acetabular component significantly affects the PSI when lumbar-pelvic alignment changes and rebalances after THA in patients with Crowe III/IV DDH.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Du H, Qiao H, Zhai ZJ, et al. Acetabular component position significantly influences the rebalancing of pelvic sagittal inclination following total hip arthroplasty in patients with Crowe type III/IV developmental dysplasia of the hip. Bone Joint J. 2025. PMID: 39889760. doi:10.1302/0301-620X.107B2.BJJ-2024-0485.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。