文献速递关节外科运动医学

全局覆盖过度与长期生存率、软骨唇交界破坏及关节间隙宽度减少的关联:至少8年随访

Association Between Global Overcoverage and Long-term Survivorship, Chondrolabral Junction Breakdown, and Reduced Joint Space Width: Minimum 8-Year Follow-up.
PubMed 文献 · Am J Sports Med · 2025-02-19

这项回顾性队列研究将38例股骨髋臼撞击症伴全局覆盖过度(GO)的患者与匹配对照1:1配对,比较基线关节间隙宽度、术中软骨唇交界破坏及至少8年随访的长期结局。GO组基线50°处关节间隙宽度显著更低且软骨唇交界破坏更重;6至18年无全髋关节置换生存率下降幅度GO组显著大于对照组。

要点

  • 全局覆盖过度患者基线50°处关节间隙宽度显著低于匹配对照(P=0.002)。
  • 全局覆盖过度患者术中软骨唇交界破坏程度显著更重(P=0.037)。
  • 6至18年无全髋关节置换生存率下降幅度全局覆盖过度组显著大于对照组(P=0.008)。

核心结论

  • 全局覆盖过度患者基线同侧50°处关节间隙宽度显著更低,术中软骨唇交界破坏严重程度更高。
  • 全局覆盖过度组在髋关节镜术后6至18年无全髋关节置换生存率下降幅度显著大于匹配对照组。

研究设计与样本

  • 回顾性分析,队列研究,证据等级3。
  • 查询因股骨髋臼撞击症继发髋臼唇撕裂接受髋关节镜治疗的患者。
  • 纳入标准包括至少8年随访时完整患者报告结局指标、髋臼壁投影位于坐骨耻骨线内侧提示髋臼陷凹、外侧中心边缘角>40°。
  • 按性别、年龄、体重指数、Tönnis分级和唇治疗1:1匹配至髋臼覆盖正常的匹配对照组。
  • 共38例全局覆盖过度患者与匹配对照1:1配对。

主要发现

  • 全局覆盖过度组基线50°处关节间隙宽度显著低于匹配对照组(P=0.002)。
  • 全局覆盖过度组软骨唇交界破坏显著更重(P=0.037)。
  • 两组全部6项患者报告结局指标、全髋关节置换转换率、疼痛水平和患者满意度结果相似。
  • Kaplan-Meier生存分析显示总体18年无全髋关节置换生存率相似(全局覆盖过度组71.1% vs 匹配对照组84.2%;P=0.101)。
  • 6至18年无全髋关节置换生存率下降幅度全局覆盖过度组为-13.1%,匹配对照组为-5.3%,全局覆盖过度组显著更大(P=0.008)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although previous literature has established the association between femoroacetabular impingement and progressive hip osteoarthritis, there exists a paucity of studies investigating the effects of global acetabular overcoverage on chondral wear and long-term outcomes. PURPOSE: To compare baseline joint space width (JSW), intraoperative findings, long-term total hip arthroplasty (THA)-free survivorship, patient-reported outcome measures (PROMs), pain levels, and patient satisfaction in patients who underwent hip arthroscopy with global overcoverage (GO) to a matched-control (MC) cohort. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: In this retrospective analysis, the authors queried patients who underwent hip arthroscopy for acetabular labral tears secondary to femoroacetabular impingement. Patients with complete PROMs at a minimum 8-year follow-up, the presence of coxa profunda as indicated by an acetabular wall projecting medial to the ilioischial line, and a lateral center-edge angle >40° were matched 1:1 by sex, age, body mass index, Tönnis grade, and labral treatment to a MC cohort of patients who had normal acetabular coverage. Baseline radiographic and intraoperative findings were compared between cohorts. Collected outcomes include the modified Harris Hip Score, Nonarthritic Hip Score, Lower Extremity Functional Scale score, Hip Outcome Score-Activities of Daily Living, Hip Outcome Score-Sports Specific Subscale, 33-item International Hip Outcome Tool score, pain levels, patient satisfaction, and conversion to THA. RESULTS: In total, 38 patients with GO were 1:1 matched to a MC cohort. The GO cohort had significantly decreased baseline JSW at 50° (P = .002) and greater chondrolabral junction breakdown (P = .037). The GO and MC cohorts achieved similar outcomes for all 6 PROMs, rates of conversion to THA, pain levels, and patient satisfaction. Kaplan-Meier survival analysis demonstrated that the patients experienced a similar overall 18-year THA-free survival rate (GO: 71.1% vs MC: 84.2%; P = .101). To isolate the long-term effects of GO on hip arthroscopy outcomes, 6- to 18-year THA-free survivorship was examined, revealing that the GO cohort (-13.1%) experienced a significantly greater decrease compared with the MC cohort (-5.3%) (P = .008). CONCLUSION: Patients with GO had significantly lower baseline ipsilateral JSW at 50° and greater intraoperative severity of chondrolabral junction breakdown. Furthermore, the GO cohort experienced a significantly greater decrease in long-term THA-free survivorship 6 to 18 years after hip arthroscopy.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Lee JS, Gillinov SM, Siddiq BS, et al. Association Between Global Overcoverage and Long-term Survivorship, Chondrolabral Junction Breakdown, and Reduced Joint Space Width: Minimum 8-Year Follow-up. Am J Sports Med. 2025. PMID: 39972531. doi:10.1177/03635465251317738

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。