股骨头尺寸重要吗?初次全髋关节置换术中32、36与40毫米股骨头的比较:美国关节置换登记系统分析

Does Femoral Head Size Matter? A Comparison of 32-, 36-, and 40-Millimeter Heads in Primary Total Hip Arthroplasty: An American Joint Replacement Registry Analysis.
PubMed 文献 · J Arthroplasty · 2025-02-25

基于美国关节置换登记系统,纳入2012至2020年65岁及以上Medicare患者初次全髋关节置换术319,531例,比较32、36与≥40毫米股骨头的翻修风险。与32毫米相比,36毫米股骨头脱位翻修率显著更低(32毫米:0.68%,36毫米:0.46%,P<0.001);≥40毫米股骨头未降低脱位翻修率(0.51%),但与全因翻修(32毫米:2.55%,36毫米:2.37%,40毫米:2.78%,P<0.001)和感染翻修(32毫米:0.43%,36毫米:0.53%,40毫米:0.82%,P<0.001)风险增加相关。作者认为在广泛采用≥40毫米股骨头前需进一步研究。

要点

  • 36毫米股骨头较32毫米显著降低脱位翻修率(0.46% vs 0.68%,P<0.001)。
  • ≥40毫米股骨头未降低脱位翻修率(0.51%),且全因翻修(2.78%)和感染翻修(0.82%)风险增加。
  • ≥40毫米组男性更多且Charlson合并症指数更高(P<0.001),可能代表术前并发症风险更高的人群。

核心结论

  • 大尺寸股骨头(≥40毫米)在初次全髋关节置换术中不降低脱位翻修率,但与全因翻修和感染翻修风险增加相关。
  • 作者认为在广泛采用≥40毫米股骨头前需进一步研究。

研究设计与样本

  • 利用美国关节置换登记系统评估2012至2020年间65岁及以上Medicare患者所有初次全髋关节置换术病例,股骨头尺寸为32、36或≥40毫米。
  • 共纳入319,531例初次全髋关节置换术,其中32毫米84,524例(26.4%)、36毫米211,814例(66.3%)、≥40毫米23,193例(7.3%)。
  • 采用多变量分析校正年龄、性别、种族、股骨头材质和Charlson合并症指数,使用Cox比例风险模型比较组间翻修差异。

主要发现

  • 与32毫米股骨头相比,36毫米股骨头脱位翻修率显著更低(32毫米:0.68%,36毫米:0.46%,P<0.001)。
  • ≥40毫米股骨头与32和36毫米股骨头相比,未降低脱位翻修率(0.51%)。
  • ≥40毫米股骨头与32和36毫米股骨头相比,全因翻修风险增加(32毫米:2.55%,36毫米:2.37%,40毫米:2.78%,P<0.001)。
  • ≥40毫米股骨头与32和36毫米股骨头相比,感染翻修风险增加(32毫米:0.43%,36毫米:0.53%,40毫米:0.82%,P<0.001)。
  • 接受≥40毫米股骨头的患者更可能为男性且Charlson合并症指数更高(P<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 尽管多变量分析控制了人口学和合并症变量,≥40毫米股骨头组中男性更多且Charlson合并症指数更高,可能代表术前并发症风险更高的人群。
  • 作者认为在广泛采用≥40毫米股骨头前需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Studies have shown that increased femoral head size reduces the risk of dislocation in primary total hip arthroplasty (THA), but there has been limited research on femoral head sizes greater than 36 mm. METHODS: The American Joint Replacement Registry was utilized to evaluate all primary THA cases in Medicare patients aged 65 years and older who had a femoral head size of 32, 36, or ≥ 40 mm between 2012 and 2020. Patients who received a ≥ 40-mm head were more likely to be men and had a higher Charlson comorbidity index (CCI, P < 0.001). Multivariate analyses were performed to adjust for age, sex, race, femoral head composition, and CCI. Cox's proportional hazards models were used to compare differences in revision between groups. RESULTS: Of 319,531 total THA cases, 84,524 (26.4%) used a 32 mm, 211,814 (66.3%) used a 36 mm, and 23,193 (7.3%) used ≥ 40-mm femoral head. When compared to 32-mm heads, 36-mm heads had significantly lower rates of revision for dislocation (32 mm: 0.68%, 36 mm: 0.46%, P < 0.001). Femoral heads ≥ 40 mm were not associated with a decreased rate of revision for dislocation (0.51%) when compared to 32 and 36 mm heads. However, femoral heads ≥ 40 mm were associated with an increased risk of all-cause revision (32 mm: 2.55%, 36 mm: 2.37%, 40 mm: 2.78%, P < 0.001) and revision for infection (32 mm: 0.43%, 36 mm: 0.53%, 40 mm: 0.82%, P < 0.001) compared to 32 and 36 mm heads. CONCLUSIONS: Large femoral heads (≥ 40 mm) do not decrease revision for dislocation in primary THA but were associated with an increased risk of all-cause revision and revision for infection. Although demographic and comorbidity variables were controlled in our multivariate analysis, more men and higher CCI in ≥ 40-mm head patients may represent a population with a greater presurgical risk for complications. More research on ≥ 40-mm heads is warranted before widespread adoption.