文献速递关节外科

现代对称与非对称假体设计在初次全膝关节置换术中的影像学与临床比较

Radiographic and Clinical Comparisons of a Modern Symmetrical Versus Asymmetrical Implant Design in Primary Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2025-02-15

本研究在学术中心比较了225例(246膝)使用对称型股骨与胫骨假体(双9°Q角滑车设计)的初次全膝关节置换术患者与匹配的历史队列235例(236膝)使用非对称型股骨假体患者,术后一年患者报告结局、失败率及并发症无差异,对称型假体组影像学髌骨倾斜显著更小(0.5° vs 3.1°,P<0.0001),活动度无显著差异。

要点

  • 对称型与非对称型假体TKA术后一年患者报告结局、失败率和并发症无差异(P>0.05)。
  • 对称型假体组影像学髌骨倾斜显著小于非对称型组(0.5° vs 3.1°,P<0.0001)。
  • 两组术前和术后膝关节活动度无显著差异(P=0.49和P=0.25)。

核心结论

  • 对称型股骨假体设计在患者报告结局和临床结果上与非对称型设计相似。
  • 尽管存在对称型假体可能髌骨轨迹更差的担忧,现代对称型TKA设计显示出更小的髌骨倾斜,整体临床表现与非对称解剖型设计相似。

研究设计与样本

  • 在学术中心开展的比较研究,纳入225例(246膝)使用对称型胫骨和股骨假体(双9°Q角滑车设计,非左右特异性滑车)的TKA患者,与匹配的历史队列235例(236膝)使用非对称型股骨假体的患者进行比较。
  • 两组所有手术均采用相似的后方参考、测量截骨技术。
  • 评估患者人口学资料、患者报告结局、并发症、膝关节活动度,以及由独立观察者进行的影像学分析(包括髌骨倾斜和移位)。
  • 使用卡方检验和t检验进行统计分析。
  • 两组间人口学特征无显著差异。

主要发现

  • 术后一年患者报告结局、失败或并发症无差异(P>0.05)。
  • 除对称型TKA显示显著更小的髌骨倾斜(0.5° vs 3.1°,P<0.0001)外,两组影像学髌骨轨迹相似。
  • 两组术前和术后膝关节活动度无显著差异(P=0.49和P=0.25)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: While asymmetrical, left/right specific, femoral, and tibial components are commonly used in modern total knee arthroplasty (TKA), the recent introduction of a modern symmetrical, left/right nonspecific, design may afford benefits as a result of reduced implant and instrumentation requirements. Given the symmetrical trochlear design of left/right nonspecific femoral components, some concerns over patient outcomes and patellar tracking may exist. The purpose of this study was to compare the clinical and radiographic outcomes in a symmetrical TKA design to a more commonly used asymmetrical femoral component. METHODS: There were 225 patients (246 knees) who underwent TKA at an academic center with an implant featuring a symmetrical tibial and femoral component, which features a double 9° Q-angle trochlear design instead of left/right specific trochlea, and were compared to a matched historical cohort of 235 patients (236 knees) who had asymmetrical femoral components. All surgeries in both groups were performed using a similar posterior referenced, measured resection technique. Patient demographics, patient-reported outcomes (PROs), complications, knee range of motion, and radiographic analysis performed by an independent observer, including patellar tilt and displacement, were assessed. Chi-square and t-tests were used. There were no significant demographic differences between groups. RESULTS: There were no differences in PROs, failures, or complications at one year (P > 0.05). Radiographic patellar tracking was similar between groups with the exception of the symmetrical TKA demonstrating significantly less patellar tilt (0.5 versus 3.1°, P < 0.0001). There was no significant difference in preoperative or postoperative range of motion between the groups (P = 0.49 and P = 0.25). CONCLUSIONS: The symmetrical femoral design demonstrated similar PROs and outcomes to an asymmetrical design. Despite some concern that patellar tracking could be worse in a symmetrical implant, the modern symmetrical TKA design demonstrated less patellar tilt and overall appears to perform clinically similarly to an asymmetric anatomic design.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Rainey JP, Blackburn BE, Kapron CR, et al. Radiographic and Clinical Comparisons of a Modern Symmetrical Versus Asymmetrical Implant Design in Primary Total Knee Arthroplasty. J Arthroplasty. 2025. PMID: 39956496. doi:10.1016/j.arth.2025.02.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。