文献速递关节外科

旋转平台全膝关节置换术中的特征性聚乙烯损伤:临床不稳翻修患者的比较性取回研究

Distinctive Polyethylene Damage in Rotating-Platform Total Knee Arthroplasty: A Comparative Retrieval Study in Patients Revised With Clinical Instability.
PubMed 文献 · J Arthroplasty · 2025-02-18

该取回研究比较了9例因症状性屈曲不稳翻修的旋转平台全膝关节置换术(TKA-RP)患者与30例随机选取的登记队列TKA-RP取回物,发现多数临床不稳相关取回物在关节面后外侧呈现特征性聚乙烯损伤模式,提示后髁半脱位越过插入物周缘壁。

要点

  • 9例临床队列中7例在关节面后外侧出现一致的聚乙烯损伤模式。
  • 30例登记队列中9例报告临床不稳症状,8例呈现类似聚乙烯损伤模式。
  • 临床不稳相关的18例取回物中15例呈现该特征性损伤模式。

核心结论

  • 多数(18例中的15例)与临床不稳相关的TKA-RP取回物呈现关节面后外侧特征性聚乙烯损伤模式,提示后髁半脱位越过插入物周缘壁,与尸体测试预测一致。
  • 合并无菌性松动并不排除这一标志性损伤模式。

研究设计与样本

  • 比较性取回研究,纳入2013年至2019年间9例因症状性屈曲不稳行翻修的TKA-RP患者(临床队列)和30例从全因翻修取回数据库中随机选取的TKA-RP(登记队列)。
  • 聚乙烯插入物由三名经验丰富的评审者使用改良Hood法检查,并根据临床不稳和损伤模式进行分类。

主要发现

  • 临床队列9例中7例插入物在关节面后外侧呈现一致的聚乙烯损伤模式,范围从插入物边缘机器线局部消失到关节面唇部严重变形伴周缘壁轮廓丧失。
  • 该7例中有5例在翻修时两个组件均固定牢靠。
  • 登记队列30例患者中9例报告临床不稳的机械症状,其中8例插入物呈现与临床队列相似的聚乙烯损伤模式。
  • 该8例中仅2例在翻修时两个组件均固定牢靠。

局限性

  • 证据等级为IV级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Biomechanical studies suggest mobile-bearing rotating-platform total knee arthroplasty (TKA-RP) has limited tolerance of asymmetric flexion gaps, and improper balancing may result in polyethylene insert instability. We sought to identify a distinctive pattern of polyethylene insert damage associated with clinical failure of TKA-RP. METHODS: There were nine patients who had an index TKA-RP and underwent a revision for symptomatic flexion instability (clinical cohort) from 2013 to 2019. There were 30 TKA-RPs (registry cohort) that were randomly selected from an all-cause revision retrieval database with archived clinical and demographic data. Based on prior biomechanical testing, we hypothesized a distinctive pattern of polyethylene damage would occur on the postero-lateral articular surface with dynamic instability. Polyethylene inserts were inspected by three experienced reviewers using the modified Hood method and categorized according to clinical instability and damage pattern. Each registry implant was dichotomized with damage either consistent or not, with that observed in the clinical cohort. RESULTS: Of the nine, seven clinical cohort inserts exhibited a consistent pattern of polyethylene damage on the postero-lateral articular surface, ranging from localized loss of machine lines on the insert margin to gross deformation of the articular surface lip with loss of peripheral wall contour. In five of these seven knees, both components were secure at revision. Of the 30 registry cohort patients, nine reported mechanical symptoms of clinical instability. There were eight inserts that exhibited a polyethylene damage pattern similar to that observed in the "clinical cohort"; only two knees had both components secure at revision. CONCLUSIONS: The majority (15 of 18) of retrieved TKA-RP inserts associated with clinical instability exhibited a distinctive pattern of postero-lateral articular surface polyethylene damage, suggesting posterior condyle subluxation over the peripheral insert wall as predicted by cadaveric testing. Concomitant aseptic loosening did not preclude this hallmark damage pattern. LEVEL OF EVIDENCE: Level IV.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Borsinger TM, Quinlan ND, Van Citters DW, et al. Distinctive Polyethylene Damage in Rotating-Platform Total Knee Arthroplasty: A Comparative Retrieval Study in Patients Revised With Clinical Instability. J Arthroplasty. 2025. PMID: 39978652. doi:10.1016/j.arth.2025.02.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。