文献速递关节外科创伤骨科

Vancouver B2型骨折需更换股骨假体时髋臼翻修对翻修全髋关节置换的影响

The impact of acetabular revision in revision total hip arthroplasty for a Vancouver B2 fracture requiring a change of femoral component.
PubMed 文献 · Bone Joint J · 2025-02-01

本研究回顾性分析2015年1月至2022年12月150例因Vancouver B2型假体周围股骨骨折需翻修股骨假体的翻修全髋关节置换患者,比较仅翻修股骨假体与同时翻修髋臼假体(使用双动髋臼假体)的结局。结果显示两组在术中并发症、术后死亡率、失血量、输血需求、内科并发症、脱位率及再手术率方面无显著差异;保留单纯活动度髋臼假体者脱位风险显著更高(18.3% vs 6.7%,p=0.036),因术后不稳导致的再翻修率也显著更高(10% vs 0%,p=0.002)。作者推荐对初始全髋置换使用单纯活动度髋臼假体的Vancouver B2型骨折需翻修股骨假体者,常规翻修髋臼假体并改用双动髋臼假体。

要点

  • 仅翻修股骨假体与同时翻修髋臼假体并使用双动髋臼假体相比,脱位率无显著差异(11/81 vs 6/69)。
  • 保留单纯活动度髋臼假体者脱位风险显著高于双动髋臼假体(18.3% vs 6.7%,p=0.036)。
  • 保留单纯活动度髋臼假体者因术后不稳导致的再翻修率显著更高(10% vs 0%,p=0.002)。

核心结论

  • 基于这些结果,同时翻修髋臼假体与更高的死亡率或增加的并发症率无关,使用双动髋臼假体的患者显著更不易发生脱位。
  • 作者推荐对初始全髋置换使用单纯活动度髋臼假体的Vancouver B2型假体周围股骨骨折需翻修股骨假体者,常规翻修髋臼假体并改用双动髋臼假体。

研究设计与样本

  • 回顾性分析连续收集的数据库,纳入2015年1月至2022年12月期间150例翻修手术、150例患者。
  • 81例翻修仅局限于股骨假体,69例涉及股骨和髋臼两个假体的翻修。
  • 术后60例患者使用单纯活动度髋臼假体,90例使用双动髋臼假体。
  • 患者平均年龄79.7岁(SD 10.1),女性98例(65.3%),平均随访31个月(SD 2.3)。

主要发现

  • 仅翻修股骨假体组与同时翻修股骨和髋臼假体并使用双动髋臼假体组在术中并发症发生率、术后死亡率、失血量、输血需求、内科并发症、脱位率(11/81 vs 6/69)及末次随访时总体再手术需求方面无显著差异。
  • 保留单纯活动度髋臼假体者脱位风险显著高于双动髋臼假体植入者(18.3%(n=11)vs 6.7%(n=6);p=0.036)。
  • 保留单纯活动度髋臼假体者因术后不稳导致的再翻修率显著更高(10%(n=6)vs 0%;p=0.002)。

关键数值与推荐

  • 脱位率:仅翻修股骨假体组11/81 vs 同时翻修股骨和髋臼假体组6/69,无显著差异。
  • 脱位率:保留单纯活动度髋臼假体者18.3%(n=11)vs 双动髋臼假体者6.7%(n=6);p=0.036。
  • 因术后不稳导致的再翻修率:保留单纯活动度髋臼假体者10%(n=6)vs 双动髋臼假体者0%;p=0.002。

临床怎么用

  • 作者推荐对初始全髋置换使用单纯活动度髋臼假体的Vancouver B2型假体周围股骨骨折需翻修股骨假体者,常规翻修髋臼假体并改用双动髋臼假体。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to assess the necessity of revising the acetabular component in revision total hip arthroplasty (THA) in patients with a Vancouver type B2 periprosthetic femoral fracture (PFF) who require revision of the femoral component. The hypothesis was that revision of both the acetabular and femoral components and using a dual-mobility acetabular component would provide a lower postoperative risk of dislocation, without increasing perioperative morbidity and mortality. METHODS: Data were retrospectively analyzed from a continuously gathered database. We included 150 revisions, performed between January 2015 and December 2022, in 150 patients, with 81 revisions limited to only the femoral component and 69 involving revision of both components. This resulted, after surgery, in 60 patients having a simple-mobility acetabular component and 90 having a dual-mobility component. The mean age of the patients was 79.7 years (SD 10.1), and 98 were female (65.3%). The mean follow-up was 31 months (SD 2.3). RESULTS: There were no significant differences between those in whom only the femoral component was revised and those in whom both components were revised with the use of a dual-mobility acetabular component for the rate of intraoperative complications, postoperative mortality, blood loss, the requirement of a blood transfusion, medical complications, dislocation (11/81 in the femoral component-only group vs 6/69 in the femoral + acetabular component revision group) or the overall need for reoperation at the final follow-up. Patients were at a significantly higher risk for dislocation when a simple-mobility component was retained (18.3% (n = 11) vs 6.7% (n = 6) for dual-mobility implants; p = 0.036). The revision rate prompted by postoperative instability was significantly higher in patients in whom a simple-mobility acetabular component was retained at revision (10% (n = 6) vs 0%; p = 0.002). CONCLUSION: Based on these results, concurrent revision of the acetabular component was not associated with a higher rate of mortality or increased morbidity and patients in whom a dual-mobility acetabular component was used were significantly less prone to dislocation. We thus recommend routine revision of the acetabular component in favour of a dual-mobility component for patients sustaining a Vancouver B2 PFF requiring revision of the femoral component if their initial THA included a simple-mobility acetabular component.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Popa C, Le Baron M, Dobelle É, et al. The impact of acetabular revision in revision total hip arthroplasty for a Vancouver B2 fracture requiring a change of femoral component. Bone Joint J. 2025. PMID: 39889753. doi:10.1302/0301-620X.107B2.BJJ-2024-0749.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。