文献速递骨质疏松与代谢性骨病脊柱外科

机会性QCT测量的颈胸段体积骨密度或可成为成人骨质疏松的可靠标志物

Cervicothoracic volumetric bone mineral density assessed by opportunistic QCT may be a reliable marker for osteoporosis in adults.
PubMed 文献 · Osteoporos Int · 2024-12-31

本研究纳入325例(65.3±19.2岁,140名女性)接受常规多排CT扫描的患者,用卷积神经网络自动提取C2-T12各椎体小梁体积骨密度(vBMD),并与腰椎vBMD比较。颈胸段vBMD与腰椎vBMD相关性好(r=0.79),排除退变椎体后提高至r=0.89;颈椎和胸椎vBMD对骨质疏松(vBMD<80 mg/cm3)的判别AUC分别为0.94和0.97,与腰椎vBMD对椎体骨折的判别能力相当。作者认为颈胸段vBMD或可用于判定骨质疏松和预测椎体骨折。

要点

  • 颈胸段vBMD与腰椎vBMD相关性好(r=0.79),排除退变椎体后提高至r=0.89。
  • 颈椎和胸椎vBMD判别骨质疏松(vBMD<80 mg/cm3)的AUC分别为0.94和0.97。
  • 颈椎vBMD<190 mg/cm3、胸椎vBMD<100 mg/cm3为骨质疏松的潜在指标。

核心结论

  • 颈胸段体积骨密度或可用于判定骨质疏松和预测椎体骨折。

研究设计与样本

  • 纳入325例(65.3±19.2岁,140名女性)接受常规平扫或增强多排CT扫描的患者。
  • 采用基于卷积神经网络的SpineQ软件v1.0自动提取各椎体小梁vBMD,并进行异步校准和对比剂期相校正。
  • 分析C2-T12各椎体vBMD与腰椎(L1-L3,或L4和L5)平均vBMD的相关性,并考虑骨折状态和退变。

主要发现

  • 颈胸段vBMD与腰椎vBMD相关性好(r=0.79),排除退变椎体后显著提高(p<0.05;r=0.89),但C7-T3和T9除外。
  • 颈椎vBMD(AUC=0.94)和胸椎vBMD(AUC=0.97)对骨质疏松(vBMD<80 mg/cm3)有强判别能力;排除颈椎退变椎体后AUC提高至0.97。
  • 颈椎和胸椎vBMD(AUC=0.74,AUC=0.72)在区分有无现患椎体骨折方面与腰椎vBMD(AUC=0.72)相当。

关键数值与推荐

  • 颈椎小梁vBMD<190 mg/cm3和胸椎小梁vBMD<100 mg/cm3为骨质疏松的潜在指标,类似腰椎vBMD<80 mg/cm3。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: This study aimed to validate the correlation between volumetric bone mineral density in the cervicothoracic and lumbar spine using measurements from opportunistic CT scans. The bone density assessment proved feasible, allowing us to propose optimal cut-off values for diagnosing osteoporosis and predicting vertebral fractures in the cervical and thoracic spine. OBJECTIVES: To investigate the performance of cervicothoracic volumetric bone mineral density (vBMD), obtained through opportunistic quantitative computed tomography (QCT), in discriminating patients with/without osteoporosis and with/without vertebral fractures (VFs), using lumbar vBMD as the reference. METHODS: Three hundred twenty-five patients (65.3 ± 19.2 years, 140 women) with routine non-contrast or contrast-enhanced multi-detector CT (MDCT) scans were included. Trabecular vBMD was automatically extracted from each vertebra using a convolutional neural network (CNN)-based framework (SpineQ software v1.0) with asynchronous calibration and contrast phase correction. The correlations of vBMD between each vertebra spanning C2-T12 and the averaged lumbar spine (L1-L3, or L4 and L5) vBMD values were analyzed, considering fracture status and degeneration. Vertebra-specific linear regression equations were used to approximate lumbar vBMD at the cervicothoracic spine. RESULTS: Cervicothoracic vBMD correlated well with lumbar vBMD (r = 0.79), with significant improvement after excluding degenerated vertebrae (p < 0.05; r = 0.89), except for C7-T3 and T9. Cervical (AUC = 0.94) and thoracic vBMD (AUC = 0.97) showed strong discriminatory ability for osteoporosis (vBMD < 80 mg/cm3). Excluding degenerated vertebrae at the cervical spine increased the AUC to 0.97. Cervical and thoracic vBMD (AUC = 0.74, AUC = 0.72) were comparable to lumbar vBMD (AUC = 0.72) in differentiating patients with and without prevalent VFs. Trabecular vBMD < 190 mg/cm3 for the cervical spine and < 100 mg/cm3 for the thoracic spine were potential indicators of osteoporosis, similar to < 80 mg/cm3 at the lumbar spine. CONCLUSION: Cervicothoracic vBMD may allow for determination of osteoporosis and prediction of VFs.

来源:Osteoporos Int,查看原文。版权归原作者所有。

引用

  1. Ramschütz C, Sollmann N, El Husseini M, et al. Cervicothoracic volumetric bone mineral density assessed by opportunistic QCT may be a reliable marker for osteoporosis in adults. Osteoporos Int. 2024. PMID: 39738830. doi:10.1007/s00198-024-07373-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。