揭示前交叉韧带重建术后≥5年股四头肌腱与骨-髌腱-骨及腘绳肌腱自体移植物应用的现有数据状况:系统综述与Meta分析
该系统综述与Meta分析纳入27项报告前交叉韧带重建术后≥5年结局的研究,比较股四头肌腱、骨-髌腱-骨与腘绳肌腱自体移植物的效果。股四头肌腱的长期患者数据量远少于腘绳肌腱和骨-髌腱-骨,腘绳肌腱失败率最高(12.7%),其次为股四头肌腱(9.1%)和骨-髌腱-骨(6.4%),汇总比值比支持骨-髌腱-骨在失败率上优于股四头肌腱和腘绳肌腱。患者报告结局在各移植物间相当,但部分比较把握度不足。作者认为股四头肌腱的长期结局数据不足以推荐其优于腘绳肌腱或骨-髌腱-骨。
要点
- 股四头肌腱自体移植物在≥5年随访的患者数据量远少于腘绳肌腱和骨-髌腱-骨(后者约为其3倍)。
- 失败率:腘绳肌腱12.7%,股四头肌腱9.1%,骨-髌腱-骨6.4%;汇总比值比支持骨-髌腱-骨优于股四头肌腱和腘绳肌腱。
- 患者报告结局在各移植物间相当,但部分比较把握度不足。
核心结论
- 股四头肌腱自体移植物在≥5年随访的长期结局数据不足以推荐其优于腘绳肌腱或骨-髌腱-骨用于初次前交叉韧带重建。
研究设计与样本
- Meta分析,证据等级4;检索PubMed/MEDLINE、Scopus(Elsevier)、Embase和Cochrane Library数据库,纳入27项报告前交叉韧带重建术后≥5年股四头肌腱、骨-髌腱-骨或腘绳肌腱结局的研究。
主要发现
- 股四头肌腱在≥5年随访的可用患者数据量远少于腘绳肌腱和骨-髌腱-骨,后者患者数据量约为股四头肌腱的3倍。
- 失败率:腘绳肌腱12.7%,股四头肌腱9.1%,骨-髌腱-骨6.4%;汇总比值比在失败率上支持骨-髌腱-骨优于股四头肌腱和腘绳肌腱。
- 患者报告结局在各移植物类型间相当,但部分比较把握度不足。
局限性
- 部分比较把握度不足。
- 股四头肌腱在≥5年随访的长期结局数据不足。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The use of quadriceps tendon (QT) autograft for anterior cruciate ligament (ACL) reconstruction has been increasing since 2014. Studies have shown that QT is comparable to hamstring tendon (HT) and bone-patellar tendon-bone (BTB) autografts in terms of outcomes, although QT autograft has lower rates of donor site morbidity. Systematic reviews and meta-analyses have been previously conducted on this topic, although none have focused solely on data of patients at least 5 years out from surgery. HYPOTHESIS/PURPOSE: The purpose of this meta-analysis was to demonstrate that QT may not be superior to BTB and HT autografts and that long-term studies must be performed before recommending QT over other graft choices. It was hypothesized that there would be less available data at ≥5 years of follow-up for patients with QT than those with HT and BTB autografts, and that patient-reported outcomes would be similar between all 3 graft choices. STUDY DESIGN: Meta-analysis; Level of evidence, 4. METHODS: The PubMed/MEDLINE, Scopus (Elsevier), Embase, and Cochrane Library databases were queried for studies that reported on QT, BTB, or HT outcomes at ≥5 years after ACL reconstruction (ACLR). In total, 27 studies were included; patient and outcome data were collected from each. Summary odds ratios were calculated for each outcome and compared between all graft types. RESULTS: The sheer volume of available patient data on QT autografts at ≥5 years after ACLR is vastly different from what is available on HT and BTB autografts (which have almost 3 times the amount of patient data as compared with QT). HT had the highest failure rate (12.7%), followed by QT (9.1%) and BTB (6.4%); summary odds ratios favored BTB over both QT and HT in terms of failure rate. Patient-reported outcomes were comparable between graft types, although some comparisons were not adequately powered. CONCLUSION: This meta-analysis reveals critical information on the current state of the literature surrounding QT use in ACLR. Most notably, additional mid-term and long-term patient data are needed on those undergoing ACLR with QT autograft. There is not enough long-term outcome data on QT to recommend it over HT or BTB for primary ACLR.
引用
- Kurkowski SC, Thimmesch MJ, Murphy M, et al. Uncovering the State of Current Data on Quadriceps Tendon Autograft Use Versus Bone-Patellar Tendon-Bone and Hamstring Tendon Autografts in Anterior Cruciate Ligament Reconstruction at ≥5 Years After Surgery: A Systematic Review and Meta-analysis. Am J Sports Med. 2025. PMID: 39763441. doi:10.1177/03635465241266628
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。