文献速递关节外科

模块化双动假体在299例翻修全髋关节置换术的中期随访中优于大直径股骨头

Modular dual-mobility constructs outperformed large femoral heads in 299 revision total hip arthroplasties at mid-term follow-up.
PubMed 文献 · Bone Joint J · 2025-01-01

单中心研究比较299例翻修全髋关节置换术中模块化双动(MDM)假体与大直径股骨头(LFH)的中期随访结果。MDM组123例,LFH组176例,平均随访7年。MDM组在免于脱位再翻修、任何再翻修及任何脱位的十年生存率均高于LFH组,LFH组相关风险显著增加。MDM组无金属沉着或腐蚀相关再翻修或再手术。

要点

  • MDM组十年免于脱位再翻修生存率99%,LFH组91%,LFH组风险显著增加(HR 7.1)。
  • MDM组十年免于任何再翻修生存率92%,LFH组84%,LFH组风险显著增加(HR 2.6)。
  • MDM组十年免于任何脱位生存率95%,LFH组87%,LFH组风险显著增加(HR 2.7)。

核心结论

  • 在中期间随访中,与LFH相比,使用MDM假体的翻修全髋关节置换术安全有效地降低了脱位再翻修、任何再翻修及任何脱位的风险。
  • MDM组无金属沉着或腐蚀相关再翻修或再手术。

研究设计与样本

  • 单中心三级学术机构于2011年3月至2014年7月实施的299例翻修全髋关节置换术的对比研究。
  • MDM假体组123例,LFH组176例;平均年龄66岁(范围28至93),平均BMI 31 kg/m²(范围18至55),女性占45%(n=136)。
  • 平均随访7年(范围2至12)。

主要发现

  • MDM组十年免于脱位再翻修生存率99%(95% CI 95至100),LFH组91%(95% CI 84至96),LFH组脱位再翻修风险显著增加(HR 7.1,95% CI 1.3至40.8;p=0.023)。
  • MDM组十年免于任何再翻修生存率92%(95% CI 82至99),LFH组84%(95% CI 74至90),LFH组任何再翻修风险显著增加(HR 2.6,95% CI 1.1至5.9;p=0.024)。
  • MDM组十年免于任何脱位生存率95%(95% CI 85至99),LFH组87%(95% CI 78至92),LFH组任何脱位风险显著增加(HR 2.7,95% CI 1.1至6.3;p=0.028)。
  • MDM组无金属沉着或腐蚀相关再翻修或再手术。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications. METHODS: We identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision. MDM constructs were used in 123 cases, and LFHs were used in 176 cases. Mean age was 66 years (28 to 93), mean BMI was 31 kg/m2 (18 to 55), and 45% (n = 136) were female. Mean follow-up was seven years (2 to 12). RESULTS: The ten-year survival free of re-revision for dislocation was 99% (95% CI 95 to 100) in the MDM cohort and 91% (95% CI 84 to 96) in the LFH cohort, with a significantly increased risk of re-revision for dislocation in the LFH cohort (HR 7.1 (95% CI 1.3 to 40.8); p = 0.023). The ten-year survival free of any re-revision was 92% (95% CI 82 to 99%) in the MDM cohort and 84% (95% CI 74 to 90) in the LFH cohort with a significantly increased risk of any re-revision in the LFH cohort (HR 2.6 (95% CI 1.1 to 5.9); p = 0.024). The ten-year survival free of any dislocation was 95% (95% CI 85 to 99) in the MDM cohort and 87% (95% CI 78 to 92) in the LFH cohort with a significantly increased risk of any dislocation in the LFH cohort (HR 2.7 (95% CI 1.1 to 6.3); p = 0.028). There were no re-revisions or reoperations for metallosis or corrosion in the MDM cohort. CONCLUSION: In this head-to-head comparison, revision THAs with a MDM construct safely and effectively lowered the risk of re-revision for dislocation, any re-revision, and any dislocation compared to LFH at mid-term follow-up. There were no re-revisions or reoperations for metallosis or corrosion in the MDM cohort.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Carender CN, Bedard NA, Fruth KM, et al. Modular dual-mobility constructs outperformed large femoral heads in 299 revision total hip arthroplasties at mid-term follow-up. Bone Joint J. 2025. PMID: 39743935. doi:10.1302/0301-620X.107B1.BJJ-2024-0170.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。