文献速递关节外科创伤骨科

使用翻修假体组件构建的「1.5期」间隔物用于膝关节假体周围感染管理

A "1.5-Stage" Spacer Construct Using Revision Components for the Management of Periprosthetic Joint Infection of the Knee.
PubMed 文献 · J Arthroplasty · 2025-01-28

本研究回顾了46例膝关节假体周围感染接受「1.5期」间隔物置入的病例,其中12例为手工全聚乙烯胫骨组件,34例为带柄翻修组件。带柄翻修组因任何原因再手术率(17.6% vs 50.0%,P=0.028)和因间隔物松动翻修率(0.0% vs 25.0%,P=0.003)均低于手工组,感染复发无差异。作者认为带柄翻修组件的「1.5期」间隔物短期结果可观,但需更长期随访。

要点

  • 带柄翻修组件组因任何原因再手术率为17.6%,低于手工组的50.0%(P=0.028)。
  • 带柄翻修组件组因间隔物松动翻修率为0.0%,低于手工组的25.0%(P=0.003)。
  • 两组感染复发率和翻修时间无差异,2年无松动翻修生存率无统计学差异。

核心结论

  • 使用带柄翻修组件构建的「1.5期」间隔物短期结果可观,耐用间隔物可能是特定患者的选择,但需更长期随访以识别最受益的患者。

研究设计与样本

  • 回顾性筛选本机构因膝关节假体周围感染接受「1.5期」间隔物置入的患者,共46例,分为手工全聚乙烯胫骨组件组(12例)和带柄翻修组件预涂骨水泥组(34例)。

主要发现

  • 带柄翻修组因任何原因再手术率17.6%,手工组50.0%(P=0.028)。
  • 带柄翻修组因间隔物松动翻修率0.0%,手工组25.0%(P=0.003)。
  • 两组感染复发率和翻修时间无差异。
  • 2年无松动翻修生存率带柄组100%(95%CI 2.5至100.0),手工组72.9%(95%CI 26.3至96.6%),P=0.330,无统计学差异。

局限性

  • 作者指出需要更长期随访以识别最受益于该技术的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The two-stage surgical protocols used for the treatment of periprosthetic joint infection following total knee arthroplasty are associated with marked patient morbidity. As such, alternatives, such as durable "1.5-stage" spacer constructs, have gained popularity. We sought to describe the outcomes of a novel "1.5-stage" spacer construct utilizing revision stemmed-tibia implants. METHODS: Patients who underwent a "1.5-stage" for the management of a knee periprosthetic joint infectionat our institution were screened for inclusion. A "1.5-stage" was defined as a spacer placed with the intent of not performing a second stage, without the use of press-fit stems or cemented intramedullary fixation as is often done during a single-stage protocol. Procedures were categorized into two groups based on construct type: (1) hand-made constructs utilizing all-polyethylene tibial components; or (2) constructs utilizing stemmed-revision components precoated with cement before insertion. Patient demographics, comorbidities, and surgical details were collected and reported. The two-year Kaplan-Meier survival estimates for all-cause revision, revision for spacer loosening, and revision due to infection recurrence were reported. In total, 46 "1.5-stage" procedures were identified, including 12 handmade and 34 stemmed-revision constructs. RESULTS: The stemmed-revision cohort was less likely to undergo reoperation for any reason (17.6 versus 50.0%, P = 0.028) or a revision for spacer loosening (0.0 versus 25.0%, P = 0.003) compared to the hand-made cohort. There were no differences with respect to infection recurrence or time to revision. The 2-year survival from revision for loosening was higher in the stemmed cohort compared to the handmade cohort though not statistically different (100%, 95% CI [confidence interval]: 2.5 to 100.0 versus 72.9%, 95% CI: 26.3 to 96.6%, P = 0.330). CONCLUSIONS: A "1.5-stage" spacer construct using stemmed-revision components was associated with promising short-term results. Durable spacer constructs may be a viable option for select patients; however, longer-term follow-up is needed to identify patients who stand to benefit the most from this technique.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Heckmann ND, Biedermann BM, Richardson MK, et al. A "1.5-Stage" Spacer Construct Using Revision Components for the Management of Periprosthetic Joint Infection of the Knee. J Arthroplasty. 2025. PMID: 39884479. doi:10.1016/j.arth.2025.01.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。