文献速递关节外科

含局部麻醉药聚甲基丙烯酸甲酯骨水泥的机械完整性评估:对关节置换术的意义

Mechanical Integrity Assessment of Polymethylmethacrylate Bone Cement Incorporating Local Anesthetics: Implications for Joint Arthroplasty.
PubMed 文献 · J Arthroplasty · 2025-01-21

本研究评估加入粉末状局部麻醉药(盐酸利多卡因和盐酸布比卡因)对聚甲基丙烯酸甲酯(PMMA)骨水泥机械性能的影响,按ISO 5833-2002和ASTM F451-1标准测试压缩强度、弯曲模量和弯曲强度。结果显示各组间压缩强度和弯曲强度有显著差异,弯曲模量无显著差异;所有组压缩强度和弯曲模量均值超过标准最低值,但布比卡因组弯曲强度未达最低标准。

要点

  • 加入粉末状局麻药影响PMMA骨水泥的压缩强度和弯曲强度,但不影响弯曲模量。
  • 所有组压缩强度和弯曲模量均值超过ISO 5833-2002和ASTM F451-08标准最低值。
  • 布比卡因组弯曲强度未达标准最低值,利多卡因组弯曲强度超过最低值。

核心结论

  • 在PMMA骨水泥中加入粉末状局部麻醉药会影响其机械性能,具体影响压缩强度和弯曲强度,但不影响弯曲模量。
  • 尽管存在差异,所有组的压缩强度和弯曲模量均值均超过ISO 5833-2002和ASTM F451-08标准对丙烯酸骨水泥规定的最低值,但布比卡因组未达到弯曲强度最低值要求。
  • 这凸显了在将药物加入骨水泥用于植入物固定时考虑机械性能的重要性。

研究设计与样本

  • 体外研究,比较三组:PMMA、PMMA加盐酸利多卡因、PMMA加盐酸布比卡因。
  • 按照ISO 5833-2002和美国材料与试验协会F451-1标准规定的程序评估压缩强度、弯曲模量和弯曲强度。

主要发现

  • 各组间压缩强度和弯曲强度存在显著差异,弯曲模量无显著差异。
  • 所有组和利多卡因组的平均压缩强度与弯曲模量,以及利多卡因组的平均弯曲强度,均超过ISO 5833-2002和ASTM F451-08标准对丙烯酸骨水泥规定的最低值。
  • 布比卡因组未达到弯曲强度最低值。

关键数值与推荐

  • 评价标准为ISO 5833-2002和ASTM F451-1(机械性能测试程序)及ASTM F451-08(丙烯酸骨水泥最低值要求)。
  • 所有组压缩强度和弯曲模量均值超过ISO 5833-2002和ASTM F451-08标准最低值。
  • 利多卡因组弯曲强度均值超过ISO 5833-2002和ASTM F451-08标准最低值。
  • 布比卡因组弯曲强度未达到ISO 5833-2002和ASTM F451-08标准最低值。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Effective management of postsurgical pain following arthroplasty remains a challenge, lacking a definitive gold standard. As most knee and hip arthroplasties are cemented or hybrid, we used the property of bone cement as a drug carrier and added powdered local anesthetics (lidocaine hydrochloride and bupivacaine hydrochloride) to the polymethylmethacrylate (PMMA) as analgesics. However, the addition of drugs to bone cement may compromise its mechanical properties, necessitating a thorough analysis. Our objective was to assess the impact of added local anesthetics on the mechanical properties of PMMA bone cement. METHODS: Mechanical properties, including compressive strength, bending modulus, and bending strength, were evaluated following the procedure set by the International Organization for Standardization 5833-2002 and the American Society for Testing and Materials F451-1 standards. There were three of the following study groups compared: PMMA, PMMA with lidocaine hydrochloride, and PMMA with bupivacaine hydrochloride. RESULTS: Significant differences were observed between groups in compressive and bending strength, but not in bending modulus. Despite these differences, the mean compressive strength and bending modulus of all groups and the mean bending strength of the lidocaine group surpassed the minimum values set by the International Organization for Standardization 5833-2002 and American Society for Testing and Materials F 451-08 standards for acrylic bone cement. However, the bupivacaine group fell short of the minimum bending strength value. CONCLUSIONS: The addition of powdered local anesthetics to PMMA affects its mechanical properties, specifically compressive and bending strength, without compromising the bending modulus. While differences were noted, all groups surpassed the minimum standards for compressive strength and bending modulus. However, the bupivacaine group did not meet the minimum bending strength requirement. This highlights the importance of considering mechanical properties when incorporating drugs into bone cement for implant fixation.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Monfort-Mira M, Balaguer-Castro M, Jornet-Gibert M, et al. Mechanical Integrity Assessment of Polymethylmethacrylate Bone Cement Incorporating Local Anesthetics: Implications for Joint Arthroplasty. J Arthroplasty. 2025. PMID: 39848451. doi:10.1016/j.arth.2025.01.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。