文献速递关节外科

旋转铰链翻修全膝关节置换术联用与不联用多孔锥形补块辅助固定

Rotating Hinge Revision Total Knee Arthroplasty With and Without Porous Cone Adjunct Fixation.
PubMed 文献 · J Arthroplasty · 2025-01-23

本研究纳入2014年12月至2023年7月共251例使用旋转铰链假体行翻修全膝关节置换术的患者,其中184例(73.3%)使用了锥形补块(胫骨93例、股骨22例、联合69例)。结果显示锥形补块组无假体无菌性松动,但PT锥组伤口并发症发生率高于FT组和无锥组,各组再手术率无显著差异。作者认为FT和PT锥形补块联合新型旋转铰链假体似乎能有效实现稳定固定并获得良好早期结果,但需长期随访验证。

要点

  • 251例旋转铰链翻修全膝关节置换术中,184例(73.3%)使用了锥形补块,其中胫骨93例、股骨22例、联合69例。
  • 全队列中7例(2.8%)出现铰链假体无菌性松动,使用锥形补块的患者中无假体松动。
  • PT锥组伤口并发症发生率为15.4%,高于FT组的2.6%和无锥组的14.9%(P=0.017)。

核心结论

  • FT和PT锥形补块联合新型旋转铰链假体在翻修全膝关节置换术中似乎能有效实现稳定固定并获得良好早期结果。
  • 所有组无菌性松动率均较低,但无锥组无菌性松动比例最高。
  • 需要长期随访以验证这些早期发现并评估这些假体的耐久性和成本效益。

研究设计与样本

  • 研究纳入2014年12月至2023年7月期间接受旋转铰链假体翻修全膝关节置换术的251例患者。
  • 其中184例(73.3%)接受锥形补块:胫骨93例、股骨22例、联合锥形补块固定69例。
  • 收集了人口统计学、手术细节、功能结果、并发症和假体生存率数据,并使用软件进行统计分析。

主要发现

  • 队列平均年龄68岁(范围34至98),平均体重指数34.2(范围18.6至64),平均美国麻醉医师协会评分2.97(范围2至4),平均Charlson合并症指数4.03±1.88。
  • 平均随访时间1.85年(范围0至7.9),97例(40%)为男性。
  • 全队列中7例(2.8%)出现铰链假体无菌性松动;使用锥形补块的患者中无假体松动。
  • 术后伤口并发症在PT组更常见(15.4%),而FT组为2.6%、无锥组为14.9%(P=0.017)。
  • 各组再手术率无显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 需要长期随访以验证这些早期发现并评估这些假体的耐久性和成本效益。
  • 平均随访时间1.85年(范围0至7.9)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: As the number of revision total knee arthroplasties (rTKAs) continues to rise, there is increasing interest in the use of contemporary rotating hinge prostheses. These devices often incorporate porous cones to fill bone defects and enhance long-term fixation. This study evaluated the clinical and functional outcomes and survivorship in rTKA patients utilizing a rotating hinge prosthesis with flexible titanium (FT) cones, porous tantalum (PT) cones, or no cones. METHODS: From December 2014 to July 2023, 251 patients who underwent rTKA with a rotating hinge prosthesis were identified. Among them, 184 (73.3%) received cones: 93 tibial, 22 femoral, and 69 with combined cone fixation. Data were collected on demographics, surgical details, functional outcomes, complications, and implant survivorship. Statistical analyses were performed using a software program. RESULTS: The average age of the cohort was 68 years (range, 34 to 98), the mean body mass index was 34.2 (range, 18.6 to 64), mean American Society of Anesthesiologists score was 2.97 (range, two to four), and the mean Charleson Comorbidity index 4.03 ± 1.88. The mean follow-up period was 1.85 years (range, zero to 7.9), with 97 (40%) men. Aseptic loosening of the hinge implant was observed in seven patients (2.8%) across the entire cohort. In patients who had cones, none were found to be loose despite loosening of the rTKA components. Postoperatively, wound complications were more common in the PT group (15.4%) compared to the FT (2.6%) and no-cone groups (14.9%, P = 0.017). There were no significant differences in reoperation rates across the groups. CONCLUSIONS: The use of FT and PT cones with a novel rotating hinge prosthesis appears to be effective in achieving stable fixation and favorable early outcomes in rTKA. While aseptic loosening rates were low across all groups, the no-cone cohort had the highest proportion of cases. Long-term follow-up is necessary to validate these early findings and assess the durability and cost effectiveness of these implants over time.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Dandamudi S, Guerrero O, DeBenedetti A, et al. Rotating Hinge Revision Total Knee Arthroplasty With and Without Porous Cone Adjunct Fixation. J Arthroplasty. 2025. PMID: 39863061. doi:10.1016/j.arth.2025.01.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。