顶点融合对椎体拴系术生物力学影响的分析
本研究采用多体动力学模拟方法,分析T10至L3椎体拴系(VBT)在L1/2顶点融合与否两种术式下、不同生理运动时的拴系力与椎间压缩力。结果显示顶点融合使融合节段拴系力降低近861 N、相邻节段降低约100 N,但椎间压缩力增加约706 N,相邻节段尤为明显;在未融合脊柱基础上压缩力最高增加31%。作者认为顶点融合可能降低拴系断裂率,但需长期临床研究进一步评估其生物力学后果。
要点
- T10至L3拴系加L1/2顶点融合使融合节段拴系力降低近861 N,相邻节段降低约100 N。
- L1/2融合使椎间压缩力增加约706 N,相邻节段尤为明显,较未融合脊柱最高增加31%。
- 作者认为顶点融合可能降低拴系断裂率,但需长期临床研究进一步评估生物力学后果。
核心结论
- 在拴系脊柱中行L1/2融合可降低相邻节段的拴系力,因此可能降低拴系断裂率。
- 但融合导致椎间压缩力较未融合脊柱最高增加31%。
- 需要长期临床研究进一步分析和评估这些生物力学后果。
研究设计与样本
- 采用多体动力学模拟方法进行的生物力学研究。
- 分别分析T10至L3拴系脊柱与T10至L3拴系加L1/2椎间融合器融合脊柱在不同生理运动中的拴系力和椎间压缩力。
主要发现
- 带顶点融合的VBT不仅使融合节段的拴系力降低近861 N,也使相邻脊柱节段的拴系力降低约100 N。
- 可观察到椎间压缩力显著增加约706 N,尤其在相邻脊柱节段。
- 融合导致椎间压缩力较未融合脊柱最高增加31%。
关键数值与推荐
- TL弯的拴系断裂率高达60%。
- 短期临床研究显示顶点融合使拴系断裂率显著降低至10%。
- 融合节段拴系力降低近861 N,相邻节段降低约100 N。
- 椎间压缩力增加约706 N,相邻节段尤为明显,最高较未融合脊柱增加31%。
局限性
- 需要长期临床研究进一步分析和评估这些生物力学后果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Biomechanical study by using a multibody simulation approach. OBJECTIVE: Objectification of spinal biomechanics after vertebral body tethering with and without apical fusion. SUMMARY OF BACKGROUND DATA: Vertebral body tethering, a motion-preserving surgical technique for correction of adolescent idiopathic scoliosis, is increasingly being used for thoracolumbar curves. However, tether breakage remains a common problem with breakage rates up to 60% for TL curves. Therefore, surgeons have begun to adapt their surgical technique by fusing the apex. The short-term clinical studies show a significant reduction of the tether breakage rate to 10%, but little is known about the biomechanical reasons. Therefore, this study analyzes the intervertebral compression and tether force in a tethered spine without apical fusion and in a tethered spine with apical fusion between L1/2. METHODS: A multibody simulation approach was chosen to analyze the biomechanical effects of two surgical techniques during different physiological movements. The tether and intervertebral compression forces in the different instrumented segments are once analyzed for a T10 to L3 tethered spine and once for a T10 to L3 tethered with additional L1/2 fusion using an intervertebral cage. RESULTS: VBT with apical fusion reduces the prevailing tether forces not only at the fused level by nearly 861 N but also at the adjacent spinal segments by around 100 N. However, a significant increase in intervertebral compression force of ~706 N can be observed, especially at the adjacent spinal segments. CONCLUSION: L1/2 fusion in a tethered spine reduces tether forces in adjacent segments and thus might decrease the rate of tether breakage. However, fusion results in increased intervertebral compression forces by up to 31% compared with an unfused spine. Long-term clinical studies are needed to further analyze and evaluate the biomechanical consequences.
引用
- Frank J, Trobisch PD, Pishnamaz M, et al. Analysis of the Biomechanical Effects of Vertebral Body Tethering With Apical Fusion. Spine (Phila Pa 1976). 2025. PMID: 39831390. doi:10.1097/BRS.0000000000005261
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。