文献速递创伤骨科关节外科

髋部骨折半髋关节置换术中的血流动力学测量

Haemodynamic measurements during hip hemiarthroplasty surgery for hip fracture.
PubMed 文献 · Bone Joint J · 2025-01-01

研究在WHiTE 5试验单中心入组患者中,用LiDCOrapid CNAP指套连续监测骨水泥型或现代非骨水泥型半髋置换术中的动脉血压,46例有完整记录者中4例骨水泥型(15%)和1例非骨水泥型(5%)出现收缩压下降20%至30%,发生于骨水泥注入后5分钟内或最终复位时,伴心输出量与每搏量下降。

要点

  • 骨水泥型半髋置换术中4例(15%)出现收缩压下降20%至30%。
  • 非骨水泥型组1例(5%)出现收缩压下降20%至30%。
  • 血压下降发生于骨水泥注入后5分钟内或最终假体复位时,伴心输出量与每搏量下降。

核心结论

  • 髋半髋置换术中观察到两个潜在血流动力学不稳定时段:骨水泥注入股骨髓腔后5分钟内,以及假体最终复位后(骨水泥型与非骨水泥型半髋置换均观察到)。
  • 血压下降似乎由心输出量和每搏量降低驱动。

研究设计与样本

  • 在WHiTE 5试验单中心入组、随机分配至骨水泥型或现代非骨水泥型半髋关节置换的患者中,术中用LiDCOrapid CNAP指套连续无创动脉压监测测量动脉血压。
  • 共获得56例患者测量数据,其中46例有完整记录并纳入分析。

主要发现

  • 骨水泥型半髋置换组4例(15%)出现收缩压下降20%至30%,非骨水泥型组1例(5%)出现收缩压下降20%至30%。
  • 血压下降发生于骨水泥注入后5分钟内或最终髋关节复位时。
  • 观察到心输出量和每搏量同时下降。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: There is compelling evidence for the use of cemented hip hemiarthroplasty for displaced intracapsular hip fractures; however, the risks of cement are well reported and in rare cases may be associated with haemodynamic collapse. It is therefore important to improve our understanding of haemodynamic instability, intraoperative monitoring, and strategies to reduce the risk to patients. METHODS: We measured arterial blood pressure using the LiDCOrapid Continuous Non-invasive Arterial Pressure (CNAP) finger cuff during surgery in patients enrolled in the WHiTE 5 trial randomized to cemented or modern uncemented hip hemiarthroplasty at a single recruiting site. We observed the incidence, timing, and magnitude of haemodynamic instability at key stages of the surgical procedure. RESULTS: We obtained measurements from 56 patients, of whom 46 had complete recordings and were used in the analysis. Modest falls in systolic blood pressure (20% to 30%) occurred in four patients (15%) who received a cemented hemiarthroplasty and one patient (5%) in the uncemented group. The fall in blood pressure occurred either within five minutes of cementing or at final hip reduction. We observed concurrent drops in cardiac output (CO) and stroke volume (SV). CONCLUSION: We observed the presence of two potential periods for haemodynamic instability during hip hemiarthroplasty surgery: the first was within five minutes of cementing the femoral canal and the second after final reduction of the prosthesis (observed in both cemented and uncemented hemiarthroplasty). The falls in blood pressure appeared to be driven by reduced CO and SV.

来源:Bone Joint J,查看原文。版权归原作者所有。