120°屈膝位磁共振成像对半月板斜坡损伤检出与分型的诊断准确性
本研究回顾性分析2019年2月至2024年1月连续154例前交叉韧带重建患者的3-T磁共振成像,比较近伸直位与120°屈膝位对半月板斜坡损伤的诊断效能。关节镜证实62例(40.3%)存在斜坡损伤;屈膝位磁共振成像的敏感度91.9%、特异度94.6%,均显著优于近伸直位(69.4%、77.2%),分型准确性亦更高(49 vs 11,P < .001)。
要点
- 120°屈膝位磁共振成像对半月板斜坡损伤的敏感度91.9%、特异度94.6%,近伸直位分别为69.4%、77.2%。
- 屈膝位磁共振成像分型准确性显著高于近伸直位(49 vs 11,P < .001)。
- 急性病例中屈膝位诊断准确性显著更高(P < .05),慢性病例中无显著差异。
核心结论
- 120°屈膝位磁共振成像对半月板斜坡损伤的检出和分型准确性优于近伸直位。
研究设计与样本
- 回顾性分析前瞻性收集的2019年2月至2024年1月连续154例接受前交叉韧带重建的患者数据,证据等级2级。
主要发现
- 关节镜观察到的斜坡损伤为62例(40.3%)。
- 近伸直位磁共振成像的敏感度为69.4%、特异度为77.2%,屈膝位分别为91.9%和94.6%,屈膝位显著更优(P = .003和P < .001)。
- 两种体位磁共振成像的条件相对比值比为10.3(95% CI,4.82-21.8)。
- 屈膝位磁共振成像的分型准确性显著高于近伸直位(准确性49 vs 11,P < .001)。
- 急性病例中120°屈膝位磁共振成像的诊断准确性显著高于近伸直位(P < .05),慢性病例中无显著差异。
关键数值与推荐
- 诊断参考标准为前交叉韧带重建术中关节镜证实斜坡损伤,并采用Thaunat分型。
- 屈膝位磁共振成像敏感度91.9%、特异度94.6%;近伸直位敏感度69.4%、特异度77.2%。
- 屈膝位磁共振成像分型准确性49,近伸直位为11(P < .001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Detection of meniscal ramp lesions concomitant with anterior cruciate ligament (ACL) injury using conventional magnetic resonance imaging (MRI) has low sensitivity, and these lesions are currently difficult to diagnose preoperatively. PURPOSE/HYPOTHESIS: The purpose of this study was to assess the accuracy of MRI in detecting the presence of meniscal ramp lesions in the 120° flexed-knee position compared with that in the near-extended-knee position. It was hypothesized that the diagnostic performance of MRI in the 120° flexed-knee position would be better than that in the extended-knee position. STUDY DESIGN: Cohort study (Diagnosis); Level of evidence, 2. METHODS: This retrospective study of prospectively collected data between February 2019 and January 2024 included 154 consecutive patients undergoing ACL reconstruction. All patients underwent 3-T MRI examination in the near extended- and 120° flexed-knee positions preoperatively. The presence and Thaunat classification of ramp lesions were separately detected on each MRI scan and confirmed via arthroscopy during ACL reconstruction. Diagnostic sensitivity, specificity, and conditional relative odds ratios for detecting ramp lesions and the classification accuracy were compared between 2 MRI modalities. The accuracies of these MRI scans in acute and chronic cases were also evaluated. RESULTS: This study included 154 patients (79 male and 75 female; mean age, 29.0 ± 14.2 years). A total of 62 ramp lesions (40.3%) were observed on arthroscopy. The sensitivity and specificity of MRI in near extension were 69.4% and 77.2%, respectively, and those in flexion were 91.9% and 94.6%, respectively, with significant superiority in MRI at knee flexion (P = .003 and P < .001, respectively). The conditional relative odds ratio between the MRI examinations at these 2 positions was 10.3 (95% CI, 4.82-21.8). The classification accuracy of MRI in flexion was significantly higher than that of MRI in near extension (accuracy, 49 vs 11; P < .001). The diagnostic accuracy of MRI in the 120° flexed-knee position was significantly higher than that in the near-extended-knee position in the acute cases (P < .05); however, no significant differences were observed in the chronic cases. CONCLUSION: The diagnostic accuracy of MRI in the 120° flexed-knee position for detecting and classifying meniscal ramp lesions was superior to that of MRI in the near-extended-knee position.
引用
- Nonaka S, Hatayama K, Tokunaga S, et al. Diagnostic Accuracy of Magnetic Resonance Imaging in the 120° Flexed-Knee Position for Detecting and Classifying Meniscal Ramp Lesion. Am J Sports Med. 2024. PMID: 39511760. doi:10.1177/03635465241290516
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。