维持冠状面力线与关节线倾斜度对单髁膝关节置换术无影响:五年随访临床结果
本研究回顾性纳入2017至2019年接受固定平台内侧单髁膝关节置换术的325例患者,采用运动学对线策略与骨水泥型表面置换假体。术后62.4%患者CPAK分类发生改变,平均随访66.1个月时,CPAK维持组与改变组的假体生存率及所有临床评分均相似。
要点
- 内侧单髁膝关节置换术前CPAK 1型最常见,占150例(46.1%)。
- 术后203例(62.4%)CPAK分类改变,122例(37.5%)维持原分类。
- 平均随访66.1个月,CPAK维持组与改变组假体生存率及临床评分均相似。
核心结论
- 单髁膝关节置换术可使超过半数患者的术前CPAK分类发生改变。
- 术后维持冠状面力线与关节线倾斜度对患者报告结局或假体生存率均无影响。
研究设计与样本
- 回顾性队列研究,纳入2017至2019年接受固定平台内侧单髁膝关节置换术的325例患者,采用运动学对线策略与骨水泥型表面置换假体。
- 术前术后均使用全长站立位X线片测量,由两名独立观察者测量对线参数并制作CPAK分类图。
- 末次随访时使用临床评分评估患者结局,证据等级为IV级回顾性队列系列。
主要发现
- 术前CPAK 1型最常见,占150例(46.1%);术后最常见的CPAK类型为2型。
- 与术前分布相比,术后1型和4型的患病率下降,其余所有类型的分布增加。
- 203例(62.4%)患者术后CPAK分类发生改变,122例(37.5%)维持术前原CPAK分类(P = 0.003)。
- 平均随访66.1个月(范围54至75个月),CPAK维持组与改变组的假体生存率相似(P = 0.9),所有临床评分在两组间也相似(所有P > 0.05)。
局限性
- 证据等级为IV级,属回顾性队列系列。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The applicability of the coronal plane alignment of the knee (CPAK) classification for unicompartmental knee arthroplasty (UKA) is not yet clear. The current study aimed to address the following questions: 1) what is the distribution of the CPAK classification among patients who underwent medial UKA? and 2) what would be the clinical outcomes for patients whose coronal alignment and joint line obliquity have either changed or been maintained postoperatively? METHODS: This retrospective study involved 325 patients treated with fixed-bearing medial UKA between 2017 and 2019 following a kinematic alignment strategy and using cemented resurfacing implants. Long-leg standing radiographs were utilized for all preoperative and postoperative measurements. There were two independent observers who measured the alignment parameters. The patient's CPAK classification diagram was subsequently created. At the last follow-up, patients' outcomes were assessed using the clinical scores. RESULTS: The CPAK type 1 was the most prevalent type among 150 (46.1%) patients. Postoperatively, the most common CPAK type was type 2. In comparison to the preoperative distribution, there was a decrease in the prevalence of Types 1 and 4 in the postoperative distribution, whereas an increase in the distribution of all other types was noted. A total of 203 patients (62.4%) experienced CPAK classification change postoperatively, of which 122 patients (37.5%) maintained their original preoperative CPAK classification (P = 0.003). At a mean follow-up of 66.1 months (range, 54 to 75), implant survival (P = 0.9) and all clinical scores were similar between the CPAK Maintained and Changed groups (P > 0.05 for all). CONCLUSIONS: The use of UKA may alter the preoperative CPAK distribution in more than half of the patients. Following UKA, a maintained coronal alignment and joint line obliquity do not have an impact on either patient-reported outcomes or implant survival. LEVEL OF EVIDENCE: IV, retrospective cohort series.
引用
- Sahbat Y, Gulagaci F, Mabrouk A, et al. Maintenance of Coronal Alignment and Joint Line Obliquity Has No Effect on Unicompartmental Knee Arthroplasty: Clinical Results at Five Years Follow-Up. J Arthroplasty. 2024. PMID: 39586406. doi:10.1016/j.arth.2024.11.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。