使用多孔钽非骨水泥组件处理髋臼缺损并在翻修全髋关节置换术中恢复髋关节旋转中心:至少十年临床与影像学研究
本研究回顾2006至2013年间98例接受多孔钽非骨水泥髋臼组件翻修全髋关节置换术的患者,平均随访14年(范围10至17年),以无菌性松动再翻修为主要终点,髋臼杯生存率96%,任何原因再翻修全局生存率83.6%,平均Harris髋关节评分81分,超过80%髋关节显示骨整合影像学证据,旋转中心位置末次随访无变化。
要点
- 平均随访14年,无菌性松动再翻修髋臼杯生存率96%,任何原因再翻修全局生存率83.6%。
- 最常见并发症为脱位(13.7%)和感染(12%)。
- 平均Harris髋关节评分81分(范围39至100),超过80%髋关节显示骨整合,旋转中心位置无变化。
核心结论
- 使用多孔钽非骨水泥组件处理翻修髋关节置换术可被认为是处理髋臼缺损并恢复髋关节旋转中心的有利解决方案,长期随访临床和影像学结果满意。
研究设计与样本
- 回顾性研究,2006年至2013年间在本机构接受该手术技术的98例患者进行了临床和影像学回顾。
主要发现
- 平均随访14年(范围10至17年),髋臼杯生存率96%。
- 若以任何原因再翻修为终点,全局生存率为83.6%。
- 最常见并发症为脱位(13.7%)和感染(12%)。
- 13例患者死亡,17例患者失访,73例患者可进行临床和影像学评估。
- 平均Harris髋关节评分81分(范围39至100)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Managing acetabular defects and restoring the hip center of rotation (COR) in revision hip arthroplasty is considered a complex and challenging surgery. Among many existing options, porous tantalum components have shown favorable short-term (less than ten years) follow-up results. The present study aimed to describe clinical and radiographic outcomes in longer-term follow-up. METHODS: Between 2006 and 2013, 98 patients who underwent this surgical technique in our institute were clinically and radiographically reviewed. Rerevisions for aseptic loosening of the acetabular component were examined to consider the survivorship of the implant as the primary endpoint. The clinical outcome was measured using the Harris Hip Score. Radiological signs of osseointegration, radiolucency lines, acetabular stability, and position of the hip COR were evaluated at the immediate postoperative and last follow-up radiographs. RESULTS: The cup survivorship was 96% at a mean follow-up of 14 years (range, 10 to 17). Global survivorship was 83.6% if any reason for rerevisions was considered an endpoint. The most frequent complications were dislocation (13.7%) and infections (12%). Overall, 13 patients died, and 17 patients were lost to follow-up. There were 73 patients available for clinical and radiographic evaluation. The mean Harris Hip Score was 81 (range, 39 to 100). More than 80% of hips showed radiological evidence of osseointegration, and no change was found in COR position at last follow-up radiographs. CONCLUSIONS: The use of porous tantalum uncemented components to manage revision hip arthroplasty can be considered a favorable solution for managing acetabular defects and restoring the hip COR with satisfactory clinical and radiological results in a long-term follow-up.
引用
- Cipolla A, Vella-Baldacchino M, Le Baron M, et al. Using Porous Tantalum Uncemented Components to Manage Acetabular Defects and to Restore the Hip Center of Rotation in Revision Total Hip Arthroplasty: A Minimum Ten-Year Clinical and Radiological Study. J Arthroplasty. 2024. PMID: 39481618. doi:10.1016/j.arth.2024.10.110
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。