双动关节在初次全髋关节置换术中的中期结局:来自美国关节置换登记系统的数据
该研究基于美国关节置换登记系统,纳入2012至2018年接受初次全髋关节置换术的65岁及以上患者共207,526例,分为双动关节组、股骨头≤32毫米组和≥36毫米组。8年随访时,双动关节组全因翻修率高于其他两组,但因不稳导致的翻修率在各组间无显著差异。作者认为双动关节使用与较高的总体翻修率相关,可能归因于术者选择性地在高风险患者中使用双动关节。
要点
- 8年随访时双动关节组全因翻修率为3.5%,高于≤32毫米组的2.6%和≥36毫米组的2.7%。
- 8年随访时因不稳翻修率在双动关节组为0.4%,≤32毫米组0.5%,≥36毫米组0.3%,各组间无显著差异。
- 作者认为双动关节使用与较高的总体翻修率相关,可能归因于术者选择性地在高风险患者中使用双动关节。
核心结论
- 双动关节的使用与较高的总体翻修率相关,但各组间因不稳导致的翻修率无显著差异。
- 作者认为这些发现可能归因于术者选择性地在高风险患者中使用双动关节。
研究设计与样本
- 基于美国关节置换登记系统的数据,筛选2012至2018年间接受初次全髋关节置换术的65岁及以上患者。
- 共纳入207,526例初次全髋关节置换术,分为双动关节组(13,896例,6.7%)、股骨头≤32毫米组(60,358例,29.1%)和股骨头≥36毫米组(133,272例,64.2%)。
- 采用多变量统计模型分析患者和医院特征,使用Cox比例风险回归分析全因翻修和因不稳翻修。
主要发现
- 8年随访时,双动关节组全因翻修率为3.5%(95%CI 3.1至4.1),高于≤32毫米组的2.6%(95%CI 2.5至2.8)和≥36毫米组的2.7%(95%CI 2.5至2.9)。
- 8年随访时,因不稳翻修率在双动关节组为0.4%(95%CI 0.2至0.5),≤32毫米组为0.5%(95%CI 0.4至0.5),≥36毫米组为0.3%(95%CI 0.3至0.4),各组间无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In recent years, there has been an increased utilization of dual-mobility (DM) implants in primary total hip arthroplasty (THA) to mitigate the risk of postoperative hip instability. This study aimed to present mid-term outcomes of DM bearings in primary THA using data from the American Joint Replacement Registry. METHODS: Screening was conducted on patients aged ≥ 65 years who underwent primary THA between 2012 and 2018. Patients were categorized into three groups: (1) DM articulation, (2) ≤ 32-mm femoral head, and (3) ≥ 36-mm femoral head. Multivariable statistical modeling was employed to analyze patient and hospital characteristics, minimizing potential confounding variables and identifying independent associations with revision. Cox proportional hazards regression analyses were used to assess all-cause revision and revision specifically for instability. A total of 207,526 primary THAs were identified. Among them, 13,896 (6.7%) utilized DM articulation, 60,358 (29.1%) had a femoral head size of ≤ 32 mm, and 133,272 (64.2%) had a femoral head size of ≥ 36 mm. RESULTS: At the 8-year follow-up, the all-cause revision rate was higher in the DM group (3.5%, 95% confidence interval [CI] 3.1 to 4.1) compared to the ≤ 32-mm (2.6%, 95% CI 2.5 to 2.8) and ≥ 36-mm (2.7%, 95% CI 2.5 to 2.9) groups. However, the revision rate for instability was comparable among the DM (0.4%, 95% CI 0.2 to 0.5), ≤ 32 mm (0.5%, 95% CI 0.4 to 0.5), and ≥ 36 mm (0.3%, 95% CI 0.3 to 0.4) groups at 8-year follow-up. CONCLUSIONS: The utilization of DM was associated with higher overall revision rates. However, no significant differences in rates of revision for instability were observed among any of the bearing surface groups. These findings may be attributed to surgeons selectively utilizing DM articulations in higher-risk patients.
引用
- Heckmann ND, Palmer RC, Otero JE, et al. Dual-Mobility Articulations in Primary Total Hip Arthroplasty: Mid-Term Outcomes From the American Joint Replacement Registry. J Arthroplasty. 2024. PMID: 39515398. doi:10.1016/j.arth.2024.10.135
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。