ISTA 2023奖:全膝关节置换术中实现病前状态功能重建的探索
本研究基于21例骨关节炎患者术前CT构建病前膝关节肌骨模型,模拟机械对齐(MA)与优化植入位置对韧带应变和运动学的恢复效果。优化植入位置使最大应变均方根偏差从36.5%降至5.3%以下(前外侧韧带除外),运动学偏差从3.8 mm(SD 1.7)和4.7°(SD 1.9°)降至2.7 mm(SD 1.4)和3.7°(SD 1.9°)。作者认为优化植入位置可减少MA相对病前状态的生物力学改变,可能对机器人辅助手术的术前规划有启示。
要点
- 基于21例骨关节炎患者术前CT构建病前膝关节肌骨模型并模拟全膝关节置换植入。
- 优化植入位置使最大应变均方根偏差从36.5%降至5.3%以下(前外侧韧带除外)。
- 运动学偏差从MA的3.8 mm(SD 1.7)和4.7°(SD 1.9°)降至2.7 mm(SD 1.4)和3.7°(SD 1.9°)。
核心结论
- 优化植入位置可减少机械对齐(MA)相对病前状态引起的生物力学改变,可能对机器人辅助手术中恢复病前膝关节功能的术前规划有启示。
研究设计与样本
- 研究采用基于主动外观模型的方法分割21例骨关节炎患者的术前CT,识别无骨赘表面并从分割骨估计软骨,构建患者特异性病前膝关节肌骨模型。
- 随后模拟MA法植入,并采用既往开发的优化技术寻找使病前与术后韧带应变和运动学均方根偏差最小的最佳植入位置。
主要发现
- 模拟患者模型间存在明显生物力学差异,但也呈现群体水平可重复的趋势。
- 优化植入位置使队列内最大观测应变均方根偏差从36.5%降至5.3%以下,但前外侧韧带除外。
- 优化植入位置同时使运动学偏差从MA的3.8 mm(SD 1.7)和4.7°(SD 1.9°)降至2.7 mm(SD 1.4)和3.7°(SD 1.9°)。
- 为实现优化,股骨组件一致需要前、外、近端方向的平移调整,胫骨组件在多数病例中需要更大的后倾和內翻旋转。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The surgical target for optimal implant positioning in robotic-assisted total knee arthroplasty remains the subject of ongoing discussion. One of the proposed targets is to recreate the knee's functional behaviour as per its pre-diseased state. The aim of this study was to optimize implant positioning, starting from mechanical alignment (MA), toward restoring the pre-diseased status, including ligament strain and kinematic patterns, in a patient population. METHODS: We used an active appearance model-based approach to segment the preoperative CT of 21 osteoarthritic patients, which identified the osteophyte-free surfaces and estimated cartilage from the segmented bones; these geometries were used to construct patient-specific musculoskeletal models of the pre-diseased knee. Subsequently, implantations were simulated using the MA method, and a previously developed optimization technique was employed to find the optimal implant position that minimized the root mean square deviation between pre-diseased and postoperative ligament strains and kinematics. RESULTS: There were evident biomechanical differences between the simulated patient models, but also trends that appeared reproducible at the population level. Optimizing the implant position significantly reduced the maximum observed strain root mean square deviations within the cohort from 36.5% to below 5.3% for all but the anterolateral ligament; and concomitantly reduced the kinematic deviations from 3.8 mm (SD 1.7) and 4.7° (SD 1.9°) with MA to 2.7 mm (SD 1.4) and 3.7° (SD 1.9°) relative to the pre-diseased state. To achieve this, the femoral component consistently required translational adjustments in the anterior, lateral, and proximal directions, while the tibial component required a more posterior slope and varus rotation in most cases. CONCLUSION: These findings confirm that MA-induced biomechanical alterations relative to the pre-diseased state can be reduced by optimizing the implant position, and may have implications to further advance pre-planning in robotic-assisted surgery in order to restore pre-diseased knee function.
引用
- Tzanetis P, Fluit R, de Souza K, et al. ISTA Award 2023: Toward functional reconstruction of the pre-diseased state in total knee arthroplasty. Bone Joint J. 2024. PMID: 39481432. doi:10.1302/0301-620X.106B11.BJJ-2023-1357.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。