失败桡骨头关节置换术采用取出假体治疗
本研究回顾11例因肘部创伤急性行桡骨头关节置换术(RHA)失败后接受单纯假体取出而不重新置入的患者,平均随访8.4年。结果显示屈伸弧、旋前旋后弧、疼痛VAS、MEPS、OES及DASH评分均显著改善,10例(91%)出现异位骨化和骨关节炎,2例因僵硬和疼痛再次手术。作者认为单纯取出假体可获得满意的中期结果和可接受的并发症风险。
要点
- 11例创伤后RHA失败患者行单纯假体取出,平均随访8.4年,功能评分显著改善。
- 10例(91%)出现异位骨化和骨关节炎,2例因僵硬和疼痛再次手术。
- 作者认为单纯取出假体可获得满意的中期结果和可接受的并发症风险。
核心结论
- 对于创伤后RHA失败的患者,翻修手术时单纯取出假体可获得满意的中期结果和可接受的并发症风险。
- 在本系列中,骨关节炎、不稳定和尺桡撞击未成为问题。
研究设计与样本
- 回顾性 review 了11例因肘部创伤急性行RHA后失败、接受单纯取出假体而不重新置入作为翻修手术的患者。
- 平均随访8.4年(范围6至11年)。
- 评估内容包括肘关节活动度(ROM)和稳定性、疼痛视觉模拟评分(VAS)、Mayo肘关节性能评分(MEPS)、Oxford肘关节评分(OES)、上肢功能障碍问卷(DASH)以及影像学评估(异位骨化、假体松动、肱骨小头侵蚀、过度延长和骨关节炎)。
- 记录并发症和再次手术率。
主要发现
- 取出假体的指征为僵硬5例、无菌性松动5例、归因于RHA的疼痛3例。
- 从创伤后RHA到取出假体的平均时间间隔为10个月(范围7至21个月)。
- 术前3例存在假体过度延长,3例存在肱骨小头侵蚀,6例存在异位骨化,4例有假体松动的影像学证据。
- 末次随访时,平均屈伸弧显著改善38.2°(95%CI 20至59;P=0.002),平均旋前旋后弧显著改善20°(95%CI 0至72.5;P=0.035)。
- 平均疼痛VAS评分显著改善3.5(95%CI 2至5.5;P=0.004),平均MEPS显著改善27.5(95%CI 17.5至42.5;P=0.002),平均OES显著改善9(95%CI 2.5至14;P=0.012),平均DASH评分显著改善23.5(95%CI 7.5至31.6;P=0.012)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow. METHODS: A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded. RESULTS: The indications for removal of the implant were stiffness in five patients, aseptic loosening in five, and pain attributed to the RHA in three. The mean time interval between RHA for trauma to removal was ten months (7 to 21). Preoperatively, three patients had overlengthening of the implant, three had capitellar erosion, six had HO, and four had radiological evidence of loosening. At the final follow-up, the mean the flexion-extension arc improved significantly by 38.2° (95% CI 20 to 59; p = 0.002) and the mean arc of prono-supination improved significantly by 20° (95% CI 0 to 72.5; p = 0.035). The mean pain VAS score improved significantly by 3.5 (95% CI 2 to 5.5; p = 0.004). The mean MEPS improved significantly by 27.5 (95% CI 17.5 to 42.5; p = 0.002). The mean OES improved significantly by 9 (95% CI 2.5 to 14; p = 0.012), and the mean DASH score improved significantly by 23.5 (95% CI 7.5 to 31.6; p = 0.012). Ten patients (91%) had HO and osteoarthritis. Two patients underwent further surgery due to stiffness and pain, respectively. CONCLUSION: Simple removal of the implant at revision surgery following a failed RHA introduced following trauma provides satisfactory mid-term results with an acceptable risk of complications. Osteoarthritis, instability, and radioulnar impingement were not problems in this series.
引用
- Ameztoy Gallego J, Diez Sanchez B, Vaquero-Picado A, et al. Failed radial head arthroplasty treated by removal of the implant. Bone Joint J. 2024. PMID: 39481443. doi:10.1302/0301-620X.106B11.BJJ-2024-0330.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。