直接前入路全髋关节置换术中采用无骨水泥三锥度带领股骨柄与自动撞击的低骨折风险
本研究回顾性分析了2019至2021年间单中心四位术者连续实施的直接前入路全髋关节置换术,评估使用三锥度带领无骨水泥股骨柄联合自动撞击时的假体周围股骨骨折风险。共发生24例骨折(1.6%),其中18例(1.2%)术中识别并处理,6例(0.4%)术后识别,1例需翻修。调整回归模型显示女性、术前髋外翻和髋内翻是骨折危险因素。
要点
- 三锥度带领无骨水泥股骨柄联合自动撞击行直接前入路全髋关节置换,假体周围股骨骨折发生率为1.6%。
- 术中识别骨折18例(1.2%),术后识别6例(0.4%),仅1例需翻修。
- 调整回归模型中,女性(OR=2.76,P=0.047)、术前髋外翻(OR=4.54,P=0.005)和髋内翻(OR=2.85,P=0.03)为骨折危险因素。
核心结论
- 使用三锥度带领无骨水泥股骨柄联合自动撞击经直接前入路行全髋关节置换术时,假体周围股骨骨折发生率低。
- 研究结果与既往报告一致,即女性和术前髋外翻角是假体周围股骨骨折的危险因素。
研究设计与样本
- 回顾性综述了2019年至2021年间单中心四位经验丰富的直接前入路全髋关节置换术术者连续实施的手术。
- 收集年龄、性别、体重指数、术前诊断以及术中及术后6周内的早期假体周围股骨骨折数据。
- 术前X线片评估股骨颈干角和Dorr分型,采用Wilcoxon秩和检验或卡方检验比较骨折与无骨折患者间的差异,并进行未调整和调整回归分析评估潜在危险因素。
主要发现
- 共发生24例假体周围股骨骨折(1.6%)。
- 术中识别并处理18例骨折(1.2%),其中股骨距15例、大转子2例、后侧皮质1例。
- 术后识别6例骨折(0.4%),其中大转子5例、股骨干1例,1例需翻修手术。
- 调整回归模型中,女性(OR=2.76,P=0.047)、术前髋外翻(OR=4.54,P=0.005)和髋内翻(OR=2.85,P=0.03)为骨折危险因素。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Direct anterior approach (DAA) total hip arthroplasty (THA) has been associated with increased periprosthetic femoral fracture (PFF) risk. The aim of our study was to evaluate the fracture risk utilizing a triple tapered, collared stem with automated impaction through the anterior approach. METHODS: We retrospectively reviewed consecutive DAA THA procedures at a single institution performed by four experienced DAA THA surgeons between 2019 and 2021. We collected data on age, sex, body mass index, preoperative diagnosis, and intraoperative and early postoperative PFF within 6 weeks postoperatively. Preoperative radiographs were evaluated to determine femoral neck-shaft angle and Dorr classification. We used Wilcoxon Rank sum or Chi-square tests to assess differences between patients who did and did not have PFF. We also evaluated potential risk factors for PFF in unadjusted and adjusted regression analyses. In all, 24 PFFs (1.6%) occurred. There were eighteen fractures (1.2%) recognized and managed intraoperatively (15 calcar, 2 greater trochanter, 1 posterior cortical). There were six PFFs (0.4%) identified postoperatively (5 greater trochanter, 1 diaphyseal), of which 1 required a revision surgery. RESULTS: Identified risk factors for fracture in adjusted regression models included women (Odds Ratio (OR)=2.76, P=0.047), preoperative coxa valga (OR= 4.54, P=0.005), and coxa vara (OR=2.85, P=0.03). CONCLUSION: The incidence of periprosthetic femoral fractures is low using a triple tapered, collared cementless femoral stem with automated impaction through the DAA. Our findings agree with previous reports that have demonstrated women and preoperative valgus neck angle are risk factors for PFF.
引用
- Osondu CU, Fernandez C, Hernandez Y, et al. Low Risk of Fracture Using a Cementless Triple-tapered Collared Femoral Stem with Automated Impaction in Direct Anterior Approach Total Hip Arthroplasty. J Arthroplasty. 2023. PMID: 39492431. doi:10.1016/j.arth.2023.10.043
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。