文献速递运动医学

工程化腱-纤维软骨-骨复合物联合机械刺激增强肩袖修复:犬体内模型6个月随访研究

Engineered Tendon-Fibrocartilage-Bone Composite With Mechanical Stimulation for Augmentation of Rotator Cuff Repair: A Study Using an In Vivo Canine Model With a 6-Month Follow-up.
PubMed 文献 · Am J Sports Med · 2024-10-06

研究采用40只犬急性冈下肌腱横断模型,随机分为4组(每组10只),评估工程化腱-纤维软骨-骨复合物(TFBC)联合机械刺激对肩袖修复的功能结局,随访6个月。结果显示TFBC+BMSCs+机械刺激组失败强度高于其他修复技术,相对失败强度超过正常冈下肌腱的70%,其他组约50%,组织学显示该组脂肪浸润更少、肌纤维结构更接近正常。结论认为机械刺激工程化TFBC可促进肩袖再生,支持其用于肩袖修复增强的潜力。

要点

  • TFBC+BMSCs+机械刺激组失败强度高于其他修复技术。
  • TFBC+BMSCs+机械刺激组相对失败强度超过正常冈下肌腱70%,其他组约50%。
  • 机械刺激组组织学显示脂肪浸润更少、肌纤维结构更接近正常。

核心结论

  • 本研究提供证据表明,对工程化TFBC施加机械刺激可促进肩袖再生,从而支持其用于肩袖修复增强的潜力。

研究设计与样本

  • 控制性实验室研究,采用40只犬急性冈下肌腱横断模型,随机分配至4组(每组10只):单纯缝合修复对照组、TFBC增强组、TFBC+BMSCs增强组、TFBC+BMSCs+机械刺激组,术后6个月进行生物力学、大体外观、肌腱与肌肉形态学及组织学评估。

主要发现

  • 力学测试中,TFBC+BMSCs+机械刺激组失败强度高于其他修复技术。
  • TFBC+BMSCs+机械刺激组最常见的失败模式为撕脱骨折,而其他组主要观察到腱-骨界面断裂。
  • TFBC联合机械刺激组相对失败强度超过正常冈下肌腱的70%,其他组相对失败强度约50%。
  • 组织学分析显示,机械刺激组脂肪浸润更少,肌纤维结构更接近正常。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rotator cuff repair augmentation using biological materials has become popular in clinical practice to reduce the high retear rates associated with traditional repair techniques. Tissue engineering approaches, such as engineered tendon-fibrocartilage-bone composite (TFBC), have shown promise in enhancing the biological healing of rotator cuff tears in animals. However, previous studies have provided limited long-term data on TFBC repair outcomes. The effect of mechanical stimulation on TFBC has not been explored extensively. PURPOSE: To evaluate functional outcomes after rotator cuff repair with engineered TFBC subjected to mechanical stimulation in a 6-month follow-up using a canine in vivo model. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 40 canines with an acute infraspinatus (ISP) tendon transection model were randomly allocated to 4 groups (n =10): (1) unilateral ISP tendon undergoing suture repair only (control surgery); (2) augmentation with engineered TFBC alone (TFBC); (3) augmentation with engineered TFBC and bone marrow-derived stem cells (BMSCs) (TFBC+C); and (4) augmentation with engineered TFBC and BMSCs, as well as mechanical stimulation (TFBC+C+M). Outcome measures-including biomechanical evaluations such as failure strength, stiffness, failure mode, gross appearance, ISP tendon and muscle morphological assessment, and histological analysis-were performed 6 months after surgery. RESULTS: As shown in the mechanical test, the TFBC+C+M group exhibited higher failure strength compared with other repair techniques. The most common failure mode was avulsion fracture in the TFBC+C+M group, but tendon-bone junction rupture was observed predominantly in different groups. Engineered TFBC with mechanical stimulation showed over 70% relative failure strength compared with normal ISP, and the other groups showed about 50% relative failure strength. Histological analysis revealed less fat infiltration and closer-to-normal muscle fiber structure in the mechanical stimulation group. CONCLUSION: This study provides evidence that mechanical stimulation of engineered TFBC promotes rotator cuff regeneration, thus supporting its potential for rotator cuff repair augmentation. CLINICAL RELEVANCE: This study provides valuable evidence supporting the use of a novel tissue-engineered material (TFBC) in rotator cuff repair and paves the way for advancements in the field of rotator cuff regeneration.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Long Z, Nakagawa K, Wang Z, et al. Engineered Tendon-Fibrocartilage-Bone Composite With Mechanical Stimulation for Augmentation of Rotator Cuff Repair: A Study Using an In Vivo Canine Model With a 6-Month Follow-up. Am J Sports Med. 2024. PMID: 39370691. doi:10.1177/03635465241282668

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。